Preferred Language
Articles
/
joe-2568
Iron Permeable Reactive Barrier for Removal of Lead from Contaminated Groundwater
...Show More Authors

The possibility of using zero-valent iron as permeable reactive barrier in removing lead from a contaminated groundwater was investigated. In the batch tests, the effects of many parameters such as contact time between adsorbate and adsorbent (0-240 min), initial pH of the solution (4-8), sorbent dosage (1-12 g/100 mL), initial metal concentration (50-250 mg/L), and agitation speed
(0-250 rpm) were studied. The results proved that the best values of these parameters achieve the maximum removal efficiency of Pb+2 (=97%) were 2 hr, 5, 5 g/100 mL, 50 mg/L and 200 rpm respectively. The sorption data of Pb+2 ions on the zero-valent iron have been performed well by Langmuir isotherm model in compared with Freundlich model under the studied conditions. Finite difference method and computer solutions (COMSOL) multiphysics 3.5a software based on finite element method were used to simulate the one-dimensional equilibrium transport of lead through sand aquifer with and without presence of barrier. The predicted and experimental results proved that the reactive barrier plays a potential role in the restriction of the contaminant plume migration and a reasonable agreement between these results was recognized.

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Mon Oct 02 2023
Journal Name
Journal Of Engineering
Controlling the Unbalanced Voltages of a Series-Connected Lead-Acid Batteries in a PV Power Storage System using Dynamic Capacitor Technique
...Show More Authors

Lead-acid batteries have been used increasingly in recent years in solar power systems, especially in homes and small businesses, due to their cheapness and advanced development in manufacturing them. However, these batteries have low voltages and low capacities, to increase voltage and capacities, they need to be connected in series and parallel. Whether they are connected in series or parallel, their voltages and capacities must be equal otherwise the quality of service will be degraded. The fact that these different voltages are inherent in their manufacturing, but these unbalanced voltages can be controlled. Using a switched capacitor is a method that was used in many methods for balancing voltages, but their respons

... Show More
View Publication Preview PDF
Crossref
Publication Date
Fri Apr 29 2022
Journal Name
Iraqi Journal Of Agricultural Sciences
STABL ISOTOPES AND HYDROCHEMICAL PARAMETER AS INDICATORS OF AL-RAZZAZA LAKE WATER INTERACTION WITH GROUNDWATER SURROUNDING / KARBALA GOVERNORATE- IRAQ.
...Show More Authors

This research was aimed to study the exposure of Razzazah Lake  to major hydrological changes in recent years as a result of natural climatic changes  and  drought, high evaporation in lake due to stop discharge from Habbaniyah Lake  by Al- majera channel. During 2019, we collected surface water samples at three locations, and three samples from groundwater, in addition one samples from each location Imam Ali Drop and Sewage water  of Karbala. The Results  show that the heavy isotopes in lake and groundwater well are enriched during the warm period, and depleted during the cold period. Chemically, The dominant cations and anions in Al-Razzaza lake water are mainly of in Order  Ca > Na > Mg and  Cl>SO4 and the water

... Show More
View Publication
Crossref
Publication Date
Mon Sep 01 2014
Journal Name
Al-khwarizmi Engineering Journal
Heterogeneous Photocatalytic Degradation for Treatment of Oil from Wastewater
...Show More Authors

In the present study, advanced oxidation process / heterogeneous photocatalytic process (UV/TiO2/Fenton) system was investigated to the treatment of oily wastewater. The present study was conducted to evaluate the effect of hydrogen peroxide concentration H2O2, initial amount of the iron catalyst Fe+2, pH, temperature, amount of TiO2 and the concentration of oil in the wastewater.  The removal efficiency for the system UV/TiO2/Fenton at optimal conditions and dosage (H2O2 = 400mg/L, Fe+2 = 40mg/L, pH=5, temperature =30oC, TiO2=75mg/L) for 1000mg/L load was found to be 77%.

Aluminum foil cover around the re

... Show More
View Publication Preview PDF
Publication Date
Sun Apr 30 2023
Journal Name
Al-kindy College Medical Journal
Persistent Intraocular Pressure Elevation after Silicon Oil Removal in Patients with Post-Pars Plana Vitrectomy: IOP Level After SO Removal
...Show More Authors

Background: It is well-known that silicon oil (SO) injection into the vitreous cavity after pars plana vitrectomy is usually associated with high intraocular pressure.

Objectives: To determine the influence of silicon oil (SO) removal on IOP level after pars plana vitrectomy for spontaneous rhegmatogenous retinal detachment (RRD)

Subjects and Methods: A prospective study was conducted at Ibn Al-Haitham eye teaching hospital, Baghdad- Iraq. Intraocular pressure (IOP) was measured pre and post SO removal in patients who have underwent retinal detachment surgery with SO injection of 1000 centistokes (cSt) viscosity. Baseline IOP was measured for all the patient before the SO

... Show More
View Publication Preview PDF
Scopus Crossref
Publication Date
Tue Oct 01 2024
Journal Name
Journal Of Physics: Conference Series
An investigation into the implications of partial substitution of selenium with lead on the thermal properties for S<sub>60</sub>Se<sub>40-X</sub>Pb<sub>X</sub> Chalcogenide Compound
...Show More Authors
Abstract<p>This study includes the manufacture of four ternary alloys represented S<sub>60</sub>Se<sub>40-X</sub>Pb<sub>X</sub> with weight ratios x = 0, 10, 20, and 30 by the melting point method. The components of each alloy were mixed separately, then placed in quartz ampoules and vacuumed out with a vacuum of roger that 10<sup>−4</sup> Torr. The ampule was heated in two stages to avoid sudden dissipation and precipitation of selenium on the inner mass of the quartz tube. The ampoule was gradually heated and kept at 450°C for approximately 4 hours followed by 950°C for 10 hours.at a rate of 10 degrees Celsius, the temperature of the electric furnace</p> ... Show More
View Publication Preview PDF
Scopus Crossref
Publication Date
Thu Nov 30 2023
Journal Name
Iraqi Geological Journal
Multiple and Coherent Noise Removal from X-Profile 2D Seismic Data of Southern Iraq Using Common Depth Point Muting Procedures and Depending on Madagascar Open-Source Package
...Show More Authors

This article describes how to predict different types of multiple reflections in pre-track seismic data. The characteristics of multiple reflections can be expressed as a combination of the characteristics of primary reflections. Multiple velocities always come in lower magnitude than the primaries, this is the base for separating them during Normal Move Out correction. The muting procedure is applied in Time-Velocity analysis domain. Semblance plot is used to diagnose multiples availability and judgment for muting dimensions. This processing procedure is used to eliminate internal multiples from real 2D seismic data from southern Iraq in two stages. The first is conventional Normal Move Out correction and velocity auto picking and

... Show More
View Publication
Scopus (1)
Scopus Crossref
Publication Date
Thu Aug 18 2022
Journal Name
Dental Hypotheses
Microleakage Evaluation of Glass Hybrid Restoration Following Usage of Papain-Based Gel and Ceramic Bur for Caries Removal: An in Vitro Study
...Show More Authors

Scopus Crossref
Publication Date
Tue Jun 11 2002
Journal Name
Iraqi Journal Of Laser
The Use of a Pulsed Nd: YAG Laser Radiation for the Removal of Intracanal Debris and Smear Layer in Extracted Human Teeth
...Show More Authors

The efficiency of Nd:YAG laser radiation in removing debris and smear layer from prepared root
canal walls was studied. Fifty-seven human extracted single rooted anterior teeth were divided into three
groups. A group that was not lased is considered as a control group. The remaining teeth were exposed to
different laser parameters regarding laser energy, repetition rate and exposure time. For the case of the set of
parameters of 7 mJ laser energy, the cleaning was maximum at 3 p.p.s. repetition rate for 3 seconds exposure
time for, the coronal, middle and apical thirds. Above and below this energy level, there was an overdose
(melting) or under dose (no effect). Nevertheless for 10mJ laser energy case, the cleaning effi

... Show More
View Publication Preview PDF
Publication Date
Sat Jan 01 2011
Journal Name
Journal Of Engineering
ORGANOCLAY FOR ADSORPTION OF BINARY SYSTEM OF POLLUTANTS FROM WASTEWATER
...Show More Authors

single and binary competitive sorption of phenol and p-nitrophenol onto clay modified with
quaternary ammonium (Hexadecyltrimethyl ammonium ) was investigated to obtain the
adsorption isotherms constants for each solutes. The modified clay was prepared from
blending of local bentonite with quaternary ammonium . The organoclay was characterized
by cation exchange capacity. and surface area. The results show that paranitrophenol is
being adsorbed faster than phenol . The experimental data for each solute was fitted well with
the Freundlich isotherm model for single solute and with the combination of Freundlich-
Langmuier model for binary system .

View Publication Preview PDF
Crossref (2)
Crossref
Publication Date
Wed Nov 14 2018
Journal Name
Journal Of Engineering And Applied Sciences
DEMONSTRATE OF MAGNETIC FIELD EFFECT ON THE CAPABILITY OF ADSORPTION PROCESS IN THE REMOVAL OF AZO DYE FROM THE AQUEOUS SOLUTIONS ON CALCINED IRAQI BENTONITE CLAY MINERAL VIA COLUM
...Show More Authors