Preferred Language
Articles
/
joe-2568
Iron Permeable Reactive Barrier for Removal of Lead from Contaminated Groundwater
...Show More Authors

The possibility of using zero-valent iron as permeable reactive barrier in removing lead from a contaminated groundwater was investigated. In the batch tests, the effects of many parameters such as contact time between adsorbate and adsorbent (0-240 min), initial pH of the solution (4-8), sorbent dosage (1-12 g/100 mL), initial metal concentration (50-250 mg/L), and agitation speed
(0-250 rpm) were studied. The results proved that the best values of these parameters achieve the maximum removal efficiency of Pb+2 (=97%) were 2 hr, 5, 5 g/100 mL, 50 mg/L and 200 rpm respectively. The sorption data of Pb+2 ions on the zero-valent iron have been performed well by Langmuir isotherm model in compared with Freundlich model under the studied conditions. Finite difference method and computer solutions (COMSOL) multiphysics 3.5a software based on finite element method were used to simulate the one-dimensional equilibrium transport of lead through sand aquifer with and without presence of barrier. The predicted and experimental results proved that the reactive barrier plays a potential role in the restriction of the contaminant plume migration and a reasonable agreement between these results was recognized.

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Mon Sep 01 2014
Journal Name
Al-khwarizmi Engineering Journal
Heterogeneous Photocatalytic Degradation for Treatment of Oil from Wastewater
...Show More Authors

In the present study, advanced oxidation process / heterogeneous photocatalytic process (UV/TiO2/Fenton) system was investigated to the treatment of oily wastewater. The present study was conducted to evaluate the effect of hydrogen peroxide concentration H2O2, initial amount of the iron catalyst Fe+2, pH, temperature, amount of TiO2 and the concentration of oil in the wastewater.  The removal efficiency for the system UV/TiO2/Fenton at optimal conditions and dosage (H2O2 = 400mg/L, Fe+2 = 40mg/L, pH=5, temperature =30oC, TiO2=75mg/L) for 1000mg/L load was found to be 77%.

Aluminum foil cover around the re

... Show More
View Publication Preview PDF
Publication Date
Tue Mar 01 2011
Journal Name
Al-khwarizmi Engineering Journal
Noise Removal of ECG Signal Using Recursive Least Square Algorithms
...Show More Authors

This paper shows an approach for Electromyography (ECG) signal processing based on linear and nonlinear adaptive filtering using Recursive Least Square (RLS) algorithm to remove two kinds of noise that affected the ECG signal. These are the High Frequency Noise (HFN) and Low Frequency Noise (LFN). Simulation is performed in Matlab. The ECG, HFN and LFN signals used in this study were downloaded from ftp://ftp.ieee.org/uploads/press/rangayyan/, and then the filtering process was obtained by using adaptive finite impulse response (FIR) that illustrated better results than infinite impulse response (IIR) filters did.

View Publication Preview PDF
Publication Date
Sat Aug 01 2020
Journal Name
Journal Of Engineering
Statistical Analysis of Metal Removal during Magnetic Abrasive Finishing Process
...Show More Authors

This work aims to provide a statistical analysis of metal removal during the Magnetic Abrasive Finishing process (MAF) and find out the mathematical model which describes the relationship between the process parameters and metal removal, also estimate the impact of the parameters on metal removal. In this study, the single point incremental forming was used to form the truncated cone made of low carbon steel (1008-AISI) based on the Z-level tool path. Then the finishing was accomplished using a magnetic abrasive process based on the Box-Behnken design of the experiment using Minitab 17 software was used to finish the surface of the formed truncated cone. The influences of different parameters (feed rate, machining step s

... Show More
View Publication Preview PDF
Crossref (3)
Crossref
Publication Date
Mon Mar 04 2024
Journal Name
Journal Of Engineering
REMOVAL OF DIRECT BLUE DYE IN TEXTILEWASTEWATER EFFLUENT BY ELECTROCOAGULATION
...Show More Authors

 Removal of direct blue dye by electrocoagulation method has been investigated using aluminum   electrode in a bench-scale electrochemical system. Current density, NaCl concentration,   electrocoagulation time, and dye concentration has been studied as effecting parameters in color   removal efficiency. Increasing of current density will increase the color removal efficiency and   energy consumption as well. While increasing NaCl concentration increase the color removal   efficiency but it decrease energy consumption. High dye concentration is needed for extra   electrocaogolation time to reach the same efficiency that obtained with low dye concentration .With   current applied 0.35 amps. and NaCl concentration of 2 g/l more

... Show More
View Publication
Crossref (1)
Crossref
Publication Date
Thu Nov 30 2023
Journal Name
Iraqi Geological Journal
Multiple and Coherent Noise Removal from X-Profile 2D Seismic Data of Southern Iraq Using Common Depth Point Muting Procedures and Depending on Madagascar Open-Source Package
...Show More Authors

This article describes how to predict different types of multiple reflections in pre-track seismic data. The characteristics of multiple reflections can be expressed as a combination of the characteristics of primary reflections. Multiple velocities always come in lower magnitude than the primaries, this is the base for separating them during Normal Move Out correction. The muting procedure is applied in Time-Velocity analysis domain. Semblance plot is used to diagnose multiples availability and judgment for muting dimensions. This processing procedure is used to eliminate internal multiples from real 2D seismic data from southern Iraq in two stages. The first is conventional Normal Move Out correction and velocity auto picking and

... Show More
View Publication
Scopus Crossref
Publication Date
Tue Sep 01 2020
Journal Name
Ceramics International
High-performance (K,Na)NbO3-based binary lead-free piezoelectric ceramics modified with acceptor metal oxide
...Show More Authors

View Publication
Scopus (31)
Crossref (27)
Scopus Clarivate Crossref
Publication Date
Mon May 15 2017
Journal Name
Ibn Al-haitham Journal For Pure And Applied Sciences
Determination of the Heavy Metals in the Contaminated Soil Zones at College of Education Ibn Al-Haitham -University of Baghdad
...Show More Authors

  Soil is a crucial component of environment. Total soil analysis may give information about possible enrichment of the soil with heavy metals. Heavy metals, potentially contaminate soils, may have been dumped on the ground. The concentrations of soil heavy metals (Cd, As, Pb, Cr, Ni, Zn and Cu) were measured in three zones thought to be deeply contaminated at different depths (5, 25, 50 cm) at Ibn Al-Haitham College. The highest concentration of heavy metals Pb (63.3ppm), Cr (90.7ppm), Ni (124ppm) and Cu (75.7ppm) were found in zone (A) location-1, where the highest concentration of Zn (111.7ppm) was found in zone (C). Cd and As were detected in small amounts in all zones.     PH value, organic matters, carbonat

... Show More
View Publication Preview PDF
Publication Date
Thu Aug 18 2022
Journal Name
Dental Hypotheses
Microleakage Evaluation of Glass Hybrid Restoration Following Usage of Papain-Based Gel and Ceramic Bur for Caries Removal: An in Vitro Study
...Show More Authors

Scopus Crossref
Publication Date
Tue Jun 11 2002
Journal Name
Iraqi Journal Of Laser
The Use of a Pulsed Nd: YAG Laser Radiation for the Removal of Intracanal Debris and Smear Layer in Extracted Human Teeth
...Show More Authors

The efficiency of Nd:YAG laser radiation in removing debris and smear layer from prepared root
canal walls was studied. Fifty-seven human extracted single rooted anterior teeth were divided into three
groups. A group that was not lased is considered as a control group. The remaining teeth were exposed to
different laser parameters regarding laser energy, repetition rate and exposure time. For the case of the set of
parameters of 7 mJ laser energy, the cleaning was maximum at 3 p.p.s. repetition rate for 3 seconds exposure
time for, the coronal, middle and apical thirds. Above and below this energy level, there was an overdose
(melting) or under dose (no effect). Nevertheless for 10mJ laser energy case, the cleaning effi

... Show More
View Publication Preview PDF
Publication Date
Wed Nov 14 2018
Journal Name
Journal Of Engineering And Applied Sciences
DEMONSTRATE OF MAGNETIC FIELD EFFECT ON THE CAPABILITY OF ADSORPTION PROCESS IN THE REMOVAL OF AZO DYE FROM THE AQUEOUS SOLUTIONS ON CALCINED IRAQI BENTONITE CLAY MINERAL VIA COLUM
...Show More Authors