The present study deals with the optimum design of self supporting steel communication towers. A special technique is used to represent the tower as an equivalent hollow tapered beam with variable cross section. Then this method is employed to find the best layout of the tower among prespecified configurations. The formulation of the problem is applied to four types of tower layout
with K and X brace, with equal and unequal panels. The objective function is the total weight of the tower. The variables are the base and the top dimensions, the number of panels for the tower and member's cross section areas. The formulations of design constraints are based on the requirements of EIA and ANSI codes for allowable stresses in the members and the allowable displacement at
antenna position. The Sequential Unconstrained Minimization Technique (SUMT) is used to perform the process. Direct stiffness method is used for the analysis of the structure, with beam elements. The strain energy is used to derive the stiffness matrix for members of unsymmetrical cross section. A computer program in FORTRAN is developed to represent the tower as an equivalent beam, and generate the tower nodes and members, analysis, design and to find the optimum design. Four types of tower are studied with different load cases. The effects of earthquake and wind loadings are taken in two directions and two positions of antenna are considered in the process to seek the optimum design. The tower type of X-brace with unequal panels has the minimum weight
compared with other types of tower and the optimum design is satisfied when the angle of main leg is equal to (87O).
The optimum separators operating pressure is determined by using flash calculations and equilibrium ratios. In this study, the optimum separator size for Jambur field is calculated by using equations introduced by Arnold and Stewart and API12J Specification [1]. Because Jambur field has a high production rate two conditions are taken in the study to determine separator size, first based on production rate 80,000 bbl/day and second based on split the production between two banks A and B (40,000 bbl/day for each bank). The calculation resulted in optimum separator pressure for the first stage of 700 psi, and the second stage of 300 psi, and the third stage of 120 psi. The results show that as the number of stages increased above three-stag
... Show MoreAbstract:
Objective: To self-evaluate the effect of SBAR (Situation, Background, Assessment, and Recommendation) educational program on nurse and midwives practices in maternal health report documentation accuracy.
Methods: A quasi- experimental design was carried with the application of pre- post test for nurses and midwives’ knowledge and practices regarding SBAR communication tool. The study was held in Al-Elwia maternity teaching hospital, Al –Karckh maternity hospital and Al-Yarmouk teaching Hospital. purposive sample as it was convenient with inclusion criteria consisted of (84) nurse and midwives. The questionnaire comprised of demographic data, nurses- midwives practices of SBAR using (5) level Likert scale for assessme
The icon and the symbol represent the constituents of the communication process, through their intellectual and philosophical concepts that have been addressed by the current research that it has touched upon their importance in conveying the design idea for the recipient and showing the specificity of each one of them in the communication process. The research problem has been limited by the following question: what are the communication roles that the symbol and the icon present for the user in designing the industrial product?
The research objective is to reveal the theoretical visualization that describes the icon and the symbol in the industrial product and its importance in the communication process through stating the of simil
The corrosion protection of low carbon steel in 2.5 M HCl solution by kiwi juice was studied at different temperatures and immersion times by weight loss technique. To study the determination of the optimum conditions from statistical design in evaluation of a corrosion inhibitor, three variables, were considered as the most dominant variables. These variables are: temperature, inhibitor concentration (extracted kiwi juice) and immersion time at static conditions.
These three variables are manipulated through the experimental work using central composite rotatable Box – Wilson Experimental Design (BWED) where second order polynomial model was proposed to correlate the studied variables with the corrosion rate o
... Show MoreThe digital revolution had greatly affected the methods through which we communicate, starting from the basic concepts of the internet technology and the web content in addition to the important issues that concern the culture of the digital media, the internet governance and the variation in the digital age in general and the graphic and internal design in particular.
This research addresses an important topic that goes along with the scientific development in the field of the digital design, especially in the internal and graphic designs. This study consists of two sections: the first includes the problem of the study and the need for it. Starting from the problem of the research, there is no clear perception of the formal characte
In order to promote sustainable steel-concrete composite structures, special shear connectors that can facilitate deconstruction are needed. A lockbolt demountable shear connector (LB-DSC), including a grout-filled steel tube embedded in the concrete slab and fastened to a geometrically compatible partial-thread bolt, which is bolted on the steel section's top flange of a composite beam, was proposed. The main drawback of previous similar demountable bolts is the sudden slip of the bolt inside its hole. This bolt has a locked conical seat lug that is secured inside a predrilled compatible counter-sunk hole in the steel section's flange to provide a non-slip bolt-flange connection. Deconstruction is achieved by demounting the tube from the t
... Show MoreSteel-concrete-steel (SCS) structural element solutions are rising due to their advantages over conventional reinforced concrete in terms of cost and strength. The impact of SCS sections with various core materials on the structural performance of composites has not yet been fully explored experimentally, and in this work, both slag and polypropylene fibers were incorporated in producing eco-friendly steel-concrete-steel composite sections. This study examined the ductility, ultimate strength, failure modes, and energy absorption capacities of steel-concrete-steel filled with eco-friendly concrete, enhanced by polypropylene fiber (PPF) to understand its impact on modern structural projects. Eco-friendly concrete was produced by the partial
... Show MoreIn this paper, wireless network is planned; the network is predicated on the IEEE 802.16e standardization by WIMAX. The targets of this paper are coverage maximizing, service and low operational fees. WIMAX is planning through three approaches. In approach one; the WIMAX network coverage is major for extension of cell coverage, the best sites (with Band Width (BW) of 5MHz, 20MHZ per sector and four sectors per each cell). In approach two, Interference analysis in CNIR mode. In approach three of the planning, Quality of Services (QoS) is tested and evaluated. ATDI ICS software (Interference Cancellation System) using to perform styling. it shows results in planning area covered 90.49% of the Baghdad City and used 1000 mob
... Show MoreThermal performance of closed wet cooling tower has been investigated experimentally and theoretically
in this work. The theoretical model based on heat and mass transfer equations and heat and mass transfer balance equations which are established for steady state case. A new small indirect cooling tower was used for conducting experiments. The cooling capacity of cooling tower is 1 kW for an inlet water temperature of 38oC, a water mass velocity 2.3 kg/m2.s and an air wet bulb temperature of 26oC. This study investigates the relationship between saturation efficiency, cooling capacity and coefficient of performance of closed wet cooling tower versus different operating parameters such wet-bulb temperature, variable air-spray water fl