Preferred Language
Articles
/
joe-2395
Manufacturing and Study the performance of Selective Surfaces that used in flat plate Solar Collectors
...Show More Authors

In this research an experimental study has done for testing the thermal performance of selective surfaces used in solar collectors for substrate of iron, galvanized iron and aluminum which are commercially available. The coating process for the samples has done in two ways, the electroplating and the chemical spray pyrolysis. The results of the thermal performance test of these samples are comparing with the thermal performance of a sample without paint and other paint with black paint without shines commercially available. For the electroplated samples, the performance study has done for different immersion time in plating bath, the
distance between electrical poles, the current density, and area ratio of the sample plated area to the nickel pole face area. The chemical sprayed pyrolysis samples, study has done for different coating times, atomizing gas pressures, distance between the aperture of atomizer and the sample and the paint mass flow rate. The results showed that the best performance of the iron's
samples is the sample which is coated with two layers. The first layer is of zinc done by electroplating where the time of plating is (2 min.) and the second layer is of black nickel done by electroplating, where the time is (20 min.), the distance between the poles is (6 cm), the current density is (0.15 A/dm2 ) and area ratio of the sample plated area to the nickel pole face area is equal to (1). The percentage of the increasing in heat storage of electroplating sample to galvanized iron sample without paint at the beginning of testing the performance of samples and at the end were (58.23%& 44.97%) respectively. For aluminum samples, the best performance was regarded for two samples electroplating sample and chemical spray pyrolysis sample. The best electroplating sample was coated with a layer of black nickel where the time of plating is (20 min.), the distance between the poles is (6 cm), the current density is (0.15 A/dm2) and area ratio of the sample plated area to the nickel pole face area is equal to (1). While the best chemical spray pyrolysis sample has been coated with a layer of black nickel where the time of plating is (16 sec.) and the distance between the aperture of the reservoir and the surface of the sample is (27 cm), the amount of flow is (4.8 ml / min.), the atomizing gas pressure is (1 bar) and temperature of the sample surface is (290 0C).

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Thu Mar 04 2021
Journal Name
Journal Of Coastal Conservation
Solar system planetary alignment triggers tides and earthquakes
...Show More Authors

View Publication
Scopus (6)
Crossref (9)
Scopus Clarivate Crossref
Publication Date
Fri Apr 01 2016
Journal Name
Journal Of Economics And Administrative Sciences
The impact of cultural dimensions in nursing performance
...Show More Authors

  Abstract

          The  cultural contrast is considered of the essential subjects in the field of administration of international businesses which have great and effective role for representation in one social system for the individuals have various belongings, and the nursing performance is considered  an essential basic for health care, thus  a discussion for two variables have  done to formulate the intellectual frame for this research which are( the cultural contrast and the nursing performance). depended a questionnaire as a research tool by(90) he/ she nurses of the Iraqis and the arrivals( the

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sat Feb 02 2019
Journal Name
Journal Of The College Of Education For Women
commuities of color performance in the Holy Quran
...Show More Authors

0

View Publication Preview PDF
Publication Date
Thu Feb 01 2018
Journal Name
Journal Of Economics And Administrative Sciences
Examine of Organizational Excellence by Corporation Performance Assessment Method; Case Study in Tikrit University
...Show More Authors

The research started from the basic objective of tracking the reality of organizational excellence in educational organizations on the basis of practical application. The research in its methodology was based on the examination of organizational excellence in the way of evaluating institutional performance. Tikrit University was selected as a case study to study the reality of application to the dimensions of organizational excellence in it, The results of the analysis for ten periods during the year and month. For the accuracy of the test and its averages, it was preferable to use the T test to determine the significance of the results compared to the basic criteria.

The research found that there is an o

... Show More
View Publication Preview PDF
Crossref
Publication Date
Mon Jul 12 2021
Journal Name
Egyptian Journal Of Chemistry
GC-FID estimation of BTEX compounds in liquid oil resulting from catalytic pyrolysis of used tires
...Show More Authors

Thermal decomposition of used tires was studied under atmospheric pressure and thermal heating program up to 350 °C for 110-120 min in a glass reactor. The effects of using MgO or SiO2 as catalyst in the thermal pyrolysis of tires waste on the yield ratio, reaction time, initial degree of decomposition also the contents of BTEX compounds in resulting pyrolytic oil was estimated via GC-FID. The results showed that the MgO catalyst gave a gas output in proportion of 17.063%, a liquid in a proportion of 38.245% and a solid product in proportion of 44.733%, while the SiO2 catalyst gave proportions of 14.308%, 40.161% and 45.448% for gas, liquid and solid products respectively. The results revealed that the thermal pyrolysis produced minor cont

... Show More
View Publication
Scopus Crossref
Publication Date
Mon Mar 17 2014
Journal Name
Arabian Journal For Science And Engineering
Thermal and Hydraulic Characteristics of a Novel Helical Coiled Tube Used as a Heat Exchanger
...Show More Authors

In the present work, the thermo-fluid characteristics of a heat exchanger formed of helical coiled tubes immersed in cold water are investigated experimentally. Two types of helical coiled tube are tested, a conventional vertical single helical coiled tube and a new triple vertical helical coiled tube in parallel connection called as meshed coils. The effect of hot water flow rates inside the tubes (ranges from 2.67 to 7.08 l/min), and its inlet temperatures (namely 50, 60, 70 and 80 °C) are investigated. The experimental results show that increasing the flow rate inside the meshed coils leads to decrease the temperature difference between inlet and outlet. An enhancement of heat transfer for meshed coils compared to single coil has been n

... Show More
View Publication
Scopus (13)
Crossref (10)
Scopus Crossref
Publication Date
Fri Nov 15 2024
Journal Name
Iraqi Journal Of Science
Comparative Analysis for the Seasonal Variations of the IF2 and T Ionospheric Indices during Solar Cycles 23 and 24
...Show More Authors

In this work, a comparative analysis for the behavior and pattern of the variations of the IF2 and T Ionospheric indices was conducted for the minimum and maximum years of solar cycles 23 and 24. Also, the correlative relationship between the two ionospheric indices was examined for the seasonal periods spanning from August 1996 to November 2008 for solar cycle 23 and from December 2008 to November 2019 for solar cycle 24. Statistical calculations were performed to compare predicted values with observed values for the selected indices during the tested timeframes. The study's findings revealed that the behavior of the examined indices exhibited almost similar variations throughout the studied timeframe. The seasonal variations were

... Show More
View Publication Preview PDF
Scopus Crossref
Publication Date
Mon Mar 29 2021
Journal Name
Journal Of Engineering
Extracting Four Solar Model Electrical Parameters of Mono-Crystalline Silicon (mc-Si) and Thin Film (CIGS) Solar Modules using Different Methods
...Show More Authors

Experimental measurements were done for characterizing current-voltage and power-voltage of two types of photovoltaic (PV) solar modules; monocrystalline silicon (mc-Si) and copper indium gallium di-selenide (CIGS). The conversion efficiency depends on many factors, such as irradiation and temperature. The assembling measures as a rule cause contrast in electrical boundaries, even in cells of a similar kind. Additionally, if the misfortunes because of cell associations in a module are considered, it is hard to track down two indistinguishable photovoltaic modules. This way, just the I-V, and P-V bends' trial estimation permit knowing the electrical boundaries of a photovoltaic gadget with accuracy. This measure

... Show More
View Publication Preview PDF
Crossref (6)
Crossref
Publication Date
Sun Dec 03 2017
Journal Name
Baghdad Science Journal
Construction and Operation of Solar Energy Dish for Water Heating
...Show More Authors

Construction and operation of (2 m) parabolic solar dish for hot water application were illustrated. The heater was designed to supply hot water up to 100 oC using the clean solar thermal energy. The system includes the design and construction of solar tracking unit in order to increase system performance. Experimental test results, which obtained from clear and sunny day, refer to highly energy-conversion efficiency and promising a well-performed water heating system.

View Publication Preview PDF
Scopus (1)
Scopus Crossref
Publication Date
Thu May 01 2025
Journal Name
Process Safety And Environmental Protection
Electromembrane extraction of Cadmium (II) using a novel design of electrochemical cell with a flat sheet supported liquid membrane
...Show More Authors

View Publication
Scopus (5)
Crossref (6)
Scopus Clarivate Crossref