The performance of a solar assisted desiccant cooling system for a meeting-hall located in the College of Engineering/University of Baghdad was evaluated theoretically. The system was composed of four components; a solar air heater, a desiccant dehumidifier, a heat exchanger and an evaporative cooler. A computer simulation was developed by using MATLAB to assess the effect of various design and operating conditions on the performance of the system and its components. The actual weather data on recommended days were used to assess the load variation and the system performance during those days. The radiant time series method (RTS) was used to evaluate the hourly variation of the cooling load. Four operation modes were employed for performance evaluation. A 100 % ventilation mode and 3 recirculation modes, 30 % , 60 % and 100 % recirculation of room air. The concept of variable air volume was employed as a control strategy over the day, by changing the supply airflow rate to match the variation in the cooling load.
The results showed that the reduction in moisture content at regeneration temperatures from 55 o C to 75 o C lead to adequate removal of the high latent load in the meeting-hall. Also, the 30 % recirculation of return air resulted in comfortable indoor conditions satisfying the ventilation requirements for most periods of system operation. In addition, the COP of the system was high compared with the conventional vapor compression system. It varied from 1 to 13, when considering solar energy used to regenerate the
desiccant material as free energy.
In this study, the response and behavior of machine foundations resting on dry and saturated sand was investigated experimentally. A physical model was manufactured to simulate steady state harmonic load at different operating frequencies. The effect of relative density, depth of embedment, foundation area as well as the imposed harmonic load was investigated. It was found that the amplitude of displacement of the foundation increases with increasing the amplitude of dynamic force and operating frequency meanwhile it decreases with increasing the relative density of sand, degree of saturation, depth of embedment and contact area of footing. The maximum displacement was noticed at 33.34 to 41.67 Hz. The maximum displaceme
... Show MoreBackground: Leishmaniasis is important public
health problem owing to its impact on morbidity
and mortality and difficulties in application of
effective control measures.
Objective: The aim of the study is to evaluate the
using of impregnate bed nets in the control of
leishmaniasis.
Methods: The study was conducted throughout
the years 2004 and 2005, in Diala Governorate
(about 60km north-east Baghdad). This is the first
study in Iraq for evaluation of the impregnated bed
net in control of leishmaniasis. Two villages were
selected to achieve this aim. The nets were
distributed for the first village to be used by their
population. The second village was served as
control.
Results: The
... Show MoreObjectives: to assess the normal range of different lip parameters with gender difference and its role in esthetic procedures for Iraqi people. Methods: direct lip measurements were performed with closed lip position using a digital vernier caliper in 132 young Iraqi subjects (89 female and 43 male). Results: Lip measurements showed sexual dimorphism with higher value in men than women in six parameters. Cutaneous height of the upper lip was higher in both sexes. The mustache area in males was longer in males compared to females. Also, it was noticed that upper lip vertical thickness had a higher value, especially in subjects with cosmetic procedures. In addition to that, vertical upper lip thickness showed a higher rise in values
... Show MoreThis study has evaluated the humoral immune response in Golden Hamsters experimentally infected with Leishmania donovani along (4) times of follow up (15, 30, 60, 90) days after infection. Indirect haemagglutination test was used to determine the antibody titer through the various stages of the study. Also the progress of the infection was studied depending on some of the visceral changes caused by the parasite, like weight of liver, length & weight of spleen & the count of Leishmania parasites in spleen were measured. Results has shown that there was an increase in antibody titer & the maximum value was recorded at the 4th day of follow up (90 days after infection) as well as that there was an increase in the length of the spleen, weight
... Show MoreIn this study the prevalence of acute, sub-acute and chronic toxoplasmosis were monitored in a group of Iraqi pregnant women according to the anti-T.gondii antibodies (IgG and IgM), as well as the levels of both progesterone and estrogen hormones were measured using mini-VIDAS®technique. This study demonstrated that there was high prevalence of chronic toxoplasmosis (31.70%) when it compared with acute and sub-acute type, results also showed that the acute toxoplasmosis always related with low concentration of both progesterone and estrogen which were (5.35 ± 7.15 ng/ml) and (70.66 ± 51.08 pg/ml) respectively
Background: Mitral valve stenosis is a condition in which the hearts mitral valve is narrowed (stenosis), This narrowing blocks the valve from opening properly obstructing blood flow through the heart and the rest of the body and this causes changes in physical parameters (resistance and conductance). Aim of the study: To assess the changes in the physical parameters in mitral valve stenosis disease in different gender and age by using Doppler ultrasound. Methods : The examination of patients at the Division of Echo - at the Iraqi Center for Heart Disease in Medical City for surgery specialist - Baghdad - Iraq, during(February2009 till November2010). The current study included fifty eight cases containing (27 males and 31 females) ages rang
... Show MorePolyvinal alcohol was Cynoethylated , complex compound with Iodin in presence of Cu++ ions were preparated and their ultra violet (U.V) and infra red( IR) spectra were investigated. The prepared derivative and complexes were evaluated as antibacterial and antifungal agents following the standard dilution method. MIC(minimum inhibitory concentration) for each polymer using ten types of gram + ve and gram _ ve bacteria were determinated in addition to three types of fungi. The results obtainded showed that MIC, s were around 0.0011 × 103 molar for different polymetric derivatives tried.