Reservoir fluids properties are very important in reservoir engineering computations such as material balance calculations, well testing analyses, reserve estimates, and numerical reservoir simulations. Isothermal oil compressibility is required in fluid flow problems, extension of fluid properties from values at the bubble point pressure to higher pressures of interest and in material balance calculations (Ramey, Spivey, and McCain). Isothermal oil compressibility is a measure of the fractional change in volume as pressure is changed at constant temperature (McCain). The most accurate method for determining the Isothermal oil compressibility is a laboratory PVT analysis; however, the evaluation of exploratory wells often require an estimate of the fluid behavior prior to obtaining a representative reservoir sample. Also, experimental data is often unavailable.Empirical correlations are often used for these purposes.
This paper developed a new mathematical model for calculating undersaturated oil compressibility using 129 experimentally obtained data points from the PVT analyses of 52 bottom hole fluid samples from Mishrif reservoirs in the southern Iraqi oil fields. The new undersaturated oil compressibility correlation developed using Statistical Analysis System (SAS) by applying nonlinear multiple regression method. It was found that the new correlation estimates undersaturated oil compressibility of Mishrif reservoir crudes in the southern Iraqi oil fields much better than the published ones. The average absolute relative error for the developed correlation is 7.16%.
The objective of an Optimal Power Flow (OPF) algorithm is to find steady state operation point which minimizes generation cost, loss etc. while maintaining an acceptable system performance in terms of limits on generators real and reactive powers, line flow limits etc. The OPF solution includes an objective function. A common objective function concerns the active power generation cost. A Linear programming method is proposed to solve the OPF problem. The Linear Programming (LP) approach transforms the nonlinear optimization problem into an iterative algorithm that in each iteration solves a linear optimization problem resulting from linearization both the objective function and constrains. A computer program, written in MATLAB environme
... Show MoreWilla Cather (1873-1947) sought to capture the gradation of human emotion through carefully selected descriptive and narrative touches and firmly controlled management of dramatic scenes, situations, dialogue, and point of view. Cather’s novels and stories drew increasingly upon her personal experiences and memories.
The old settlement of Virginia and the new lands of Nebraska formed the bedding ground for Willa Cather’s talents; so did the layers of memory she found across the North American continent, from New Mexico to Canada. She saw the full-blooded European immigrants, Czechs and Swedes, plowing the unbroken land, on the way up from peasants to proprietors.
 
... Show MoreA simple, rapid and sensitive spectrophotometric method has been developed for the determination of captopril in aqueous solution. The method is based on reaction of captopril with 2,3-dichloro 1,4- naphthoquinon(Dichlone) in neutral medium to form a stable yellow colored product which shows maximum absorption at 347 nm with molar absorptivity of 5.6 ×103 L.mole-1. cm-1. The proposed method is applied successfully for determination of captopril in commercial pharmaceutical tablets.
Crop coefficient for cherries was evaluated by measure the water consumption in Michigan State to find its variation with time as the plant growth. Crop coefficients value (Kc) for cherries were predicated by Michigan State University (MSU) and also by Food and Agriculture Organization (FAO) according to consume of water through the season. In this paper crop coefficients for cherries are modified accordingly to the actual measurements of soil moisture content. Actual evapotranspiration (consumptive use) were measured by the soil moisture readings using Time Domain Reflectometers (TDR), and compared with the actual potential evapotranspiration that calculated by using modified Penman-Monteith equation which depends on metrological statio
... Show MoreA sensitive spectrofluorimetric method for the determination of glibenclamide in its tablet formulations has been proposed. The method is based on the dissolving of glibenclamide in absolute ethanol and measuring the native fluorescence at 354 nm after excitation at 302 nm. Beers law is obeyed in the concentration of 1.4 to 10 µg.ml-1 of glibenclamide with a limit of detection (LD) of 0.067 µg.ml-1 and a standard deviation of 0.614. The range percent recoveries (N=3) is 94 - 103.
The graphic privacy feature is one of the most important specifications for the existence of any type of design achievements alike, which is one of the graphic products with its multiple data, and from here the current research investigates the graphic privacy of vector graphics design with all its technical descriptions and concepts associated with it and the possibility of achieving it to the best that it should be from Where its formal structure in children's publications, where the structural structure of the current research came from the first chapter, which contained the research problem, which came according to the following question: What is the graphic privacy in the design of vector graphics in children's publ
... Show MoreA UV-Vis spectrophotometry method was developed for the determination of metoclopramide hydrochloride in pure and several pharmaceutical preparations, such as Permosan tablets, Meclodin syrups, and Plasil ampoules. The method is based on the diazotization reaction of metoclopramide hydrochloride with sodium nitrate and hydrochloric acid to yield the diazonium salt, which is then reacted with 3,5-dimethyl phenol in the presence of sodium hydroxide to form a yellow azo dye. Calibration curves were linear in the range from 0.3 to 6.5 µg/mL, with a correlation coefficient of 0.9993. The limits of detection and quantification were determined and found to be 0.18 and 0.61 µg/mL, respectively. Accuracy and precision were also determined b
... Show More