Modeling the microclimate of a greenhouse located in Baghdad under its weather conditions to calculate the heating and cooling loads by computer simulation. Solar collectors with a V-corrugated absorber plate and an auxiliary heat source were used as a heating system. A rotary silica gel desiccant dehumidifier, a sensible heat exchanger, and an evaporative cooler were added to the collectors to form an open-cycle solar assisted desiccant cooling system. A dynamic model was adopted to predict the inside air and the soil surface temperatures of the greenhouse. These temperatures are used to predict the greenhouse heating and cooling loads through an energy balance method which takes into account the soil heat gain. This is not included in conventional methods. The results showed satisfactory agreement with published papers. Also, the results of heating and cooling loads obtained revealed good agreement with those obtained from conventional methods when the soil heat gain is included. Two identical collectors in series of total area of 5.4m2 were employed as a heating system which provides an outlet air temperature of 30 o C at air mass flux of 0.06 kg/s.m2 at midday in January. While, a 65 oC outlet air temperature was achieved for the same mass flux at midday in August. The desiccant cooling system
was operated in five operating modes; the ventilation mode and four recirculation modes with 20%, 50%, 70%,and 90% recirculation. The simulation results showed that a regeneration temperature of 60-70 o C is satisfactory for a cool supply air temperature of about 19.5 o C. Also, it was noted that 20-30 % recirculation of return air would result in suitable indoor greenhouse conditions for most periods of system operation. In addition, the coefficient of performance COP of the system was high compared with the conventional vapor compression systems.
النظام السياسي اليمني : دراسة في المتغيرات الداخلية
This paper introduces a relationship between the independence of polynomials associated with the links of the network, and the Jacobian determinant of these polynomials. Also, it presents a way to simplify a given communication network through an algorithm that splits the network into subnets and reintegrates them into a network that is a general representation or model of the studied network. This model is also represented through a combination of polynomial equations and uses Groebner bases to reach a new simplified network equivalent to the given network, which may make studying the ability to solve the problem of network coding less expensive and much easier.
CNC machines are widely used in production fields since they produce similar parts in a minimum time, at higher speed and with possibly minimum error. A control system is designed, implemented and tested to control the operation of a laboratory CNC milling machine having three axes that are moved by using a stepper motor attached to each axis. The control system includes two parts, hardware part and software part, the hardware part used a PC (works as controller) connected to the CNC machine through its parallel port by using designed interface circuit. The software part includes the algorithms needed to control the CNC. The sample needs to be machined is drawn by using one of the drawing software like AUTOCAD or 3D MAX and is saved in a we
... Show More<p>Photovoltaic (PV) systems are becoming increasingly popular; however, arc faults on the direct current (DC) side are becoming more widespread as a result of the effects of aging as well as the trend toward higher DC voltage levels, posing severe risk to human safety and system stability. The parallel arc faults present higher level of current as compared with the series arc faults, making it more difficult to spot the series arc. In this paper and for the aim of condition monitoring, the features of a DC series arc fault are analyzed by analysing the arc features, performing model’s simulation in PSCAD, and carrying out experimental studies. Various arc models are simulated and investigated; for low current arcs, the heur
... Show Moreيهدف هذا العمل الى بيان طبيعة العلاقة بين الادارة بالتجوال والتجديد الاستراتيجي ، ومدى تأثير المتغير المستقل في المتغير التابع. تضمنت فقرات الاستبانة بوصفه الأداة الرئيسة لجمع البيانات ثلاث جوانب اساسية، تضمن الاول البيانات الشخصية للمستجيبين، فيما تضمن الجانب الثاني الفقرات الخاصة بمتغير الادارة بالتجوال من خلال خمسة ابعاد، فيما اشتمل الجانب الثالث على فقرات التجديد الاستراتيجي عبر تناول اربعة ابعاد. ي
... Show MoreThis work aims to show the nature of the relationship between management by walking around (the independent variable) and strategic renewal (the dependent variable), as well as it shows the effect of the independent variable on the dependent variable. Questionnaire items were considered the main tool for data collection by three basic aspects. The first involved the personal data of the respondents, while the second included items related to management by walking in five dimensions, and the third is strategic renewal items by addressing four dimensions. The tourism sector, while the community has six Excellent grade hotels was taken into account in this wor
... Show MoreAbstract
This work deals with a numerical investigation to evaluate the utilization of a water pipe buried inside a roof to reduce the heat gain and minimize the transmission of heat energy inside the conditioning space in summer season. The numerical results of this paper showed that the reduction in heat gain and energy saving could be occurred with specific values of parameters, like the number of pipes per square meter, the ratio of pipe diameter to the roof thickness, and the pipe inlet water temperature. Comparing with a normal roof (without pipes), the results indicated a significant reduction in energy heat gain which is about 37.8% when the number of pipes per m
... Show MoreThe varied thermal conductivity (insulation) of silica aerogel with heating for different pH has been investigated, it has been depended on ambient pressure drying method in the preparing silica aerogel samples, also six different pH of samples (1, 2, 3, 7, 8 and 9) were treated under five degree of heating with (50,100,150,200 and 250) ᴼC. This technique is important to test the carry-outs hydrophobic silica to temperature without high-quality material changes in the basic characteristics. The hot-wire technique is used in this work to examine the thermal conductivity, Fourier Transform Infrared Spectroscopy (FTIR) depended to characterize the bonds and their artificial by heating. Resu
... Show MoreCalcium carbonate is predominantly present in aqueous systems, which is
commonly used in industrial processes. It has inverse solubility characteristics
resulting in the deposition of scale on heat transfer surface. This paper focuses on
developing methods for inhibition of calcium carbonate scale formation in cooling
tower and air cooler system where scaling can cause serious problems, ZnCl 2 and ZnI
2 has been investigated as scale inhibitor on AISI 316 and 304. ZnCl 2 were more
effective than ZnI 2 in both systems, and AISI 316 show more receptivity to the
chlorides salt compared to AISI 304. The inhibitors were more effective in cooling
tower than air cooler system. AISI 316 show more constant inhibition effic
Background: Surgical injury to alveolar bone can temporarily accelerate tooth movement by increasing the remodeling rate of alveolar bone. The purpose of this study was to clinically evaluate maxillary canine retraction acceleration with corticotomy-facilitated orthodontics, and its effect on vitality of pulp and gingival sulcus depth. Materials and method: The sample consisted of 12 adult patients (4 males, 8 females; mean age, 21.7 years) requiring the therapeutic extraction of the maxillary first premolars, with subsequent retraction of the maxillary canines. Surgical holes were done mesially and distally to the side with more space between canine and second premolar, and the other side served as the control. Canine retraction was done