Preferred Language
Articles
/
joe-2166
Buckling Analysis Of Damaged Composite Plates Under Uniform Or Non-Uniform Compressive Load
...Show More Authors

The present study focused mainly on the buckling behavior of composite laminated plates subjected to mechanical loads. Mechanical loads are analyzed by experimental analysis, analytical analysis (for laminates without cutouts) and numerical analysis by finite element method (for laminates with and without cutouts) for different type of loads which could be uniform or non-uniform, uniaxial or biaxial. In addition to many design parameters of the laminates such as aspect ratio, thickness ratio, and lamination angle or the parameters of the cutout such as shape, size, position, direction, and radii rounding) which are changed to studytheir effects on the buckling characteristics with various boundary conditions. Levy method of classical laminated plate theory and Finite element coded by ANSYS 13.0 is used to formulate the theoretical model. Results are compared with other researches and good agreement was obtained.

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Mon Mar 01 2010
Journal Name
Al-khwarizmi Engineering Journal
Microstructure and Some Properties of Aluminum-Silicon Matrix Composites Reinforced by Alumina or Chromia
...Show More Authors

In this work, yttrium oxide particles (powder) reinforced AL-Si matrix composites (Y2O3/Al-Si) and Chromium oxide particles reinforced AL-Si matrix composites (Cr2O3/AL-Si) were prepared by direct squeeze casting. The volume percentages of yttrium oxide used are (4, 8.1, 12.1, 16.1 vol %) and the volume percentages of the chromium oxide particles used are (3.1, 6.3, 9.4, 12.5 vol. %). The parameters affecting the preparation of Y2O3/Al-Si and Cr2O3/AL-Si composites by direct squeeze casting process were studied. The molten Al-Si alloy with yttrium oxide particles or with chromium oxide particles was stirred again using an electrical stirrer at speed 500 rpm  and the molten alloy was  poured  into the squeeze die cavity. Th

... Show More
View Publication Preview PDF
Publication Date
Mon Oct 01 2018
Journal Name
International Journal Of Medical Research & Health Sciences
Non-Surgical Treatment of Gingival Recession by Platelet-Rich Plasma
...Show More Authors

Preview PDF
Publication Date
Mon Jun 30 2014
Journal Name
Al-kindy College Medical Journal
Effectiveness and safety of non-fixation method in cochlear implantation
...Show More Authors

ABSTRACTBackground: cochlear implants are electronic devices that convert sound energy into electrical signals to stimulate ganglion cells and cochlear nerve fibers. These devices are indicated for patients with severe to profound sensorineural hearing losses who receive little or no benefit from hearing aids. The implant basically takes over the function of the cochlear hair cells. The implant consists of external components (microphone, speech processor and transmitting coil) and internal components (receiver stimulator and electrode array). The implant is inserted via a trans mastoid facial recess approach to the round window and scala tympani.Objectives: to determine the effectiveness and safety of non fixation method in cochlear imp

... Show More
View Publication Preview PDF
Publication Date
Sun Oct 01 2023
Journal Name
Nanomedicine Research Journal
The effect of ZrO2 NPs addition on denture adaptation and diametral compressive strength of 3D printed denture base resin
...Show More Authors

Objective(s): The world of dentistry is constantly evolving, and with the advent of 3D printing technology, the possibilities are endless. However, little is known about the effects of adding ZrO2 NPs to the denture base resin of 3D additive manufacturing technique.Aim of this study is to evaluate the behavior of resin which is used to 3D printing of denture base with the addition of ZrO2 NPs on denture adaptation property and diametral compression strength.Methods: 60 samples were printed, 30 disks for diametral compressive test and 30 denture base for denture adaptation test. Three groups per test (n=10). The control group for each test included unreinforced 3Dprinted denture base resin, and the other groups were  reinforced with (2&

... Show More
View Publication
Publication Date
Wed May 01 2019
Journal Name
Journal Of Engineering
Using Ultrasonic Pulse Velocity Test to Assess the Effect of Water-Cement Ratio on the Compressive Strength of Concrete
...Show More Authors

This study aims to find the effect of water-cement ratio on the compressive strength of concrete by using ultrasonic pulse velocity test (UPVT). Over 230 standard cube specimens were used in this study, with dimensions of 150mm, and concrete cubes were cured in water at 20 °C. Also, the specimens used in the study were made of concrete with varied water-cement ratio contents from 0.48 to 0.59. The specimens were taken from Diyarbakir-Turkey concrete centers and tested at the structure and material science lab, civil engineering, faculty of engineering from Dicle University.  The UPV measurement and compressive strength tests were carried out at the concrete age of 28 days. Their UPV and compressive strength ranged

... Show More
View Publication Preview PDF
Crossref (2)
Crossref
Publication Date
Mon Jan 01 2024
Journal Name
Journal Of Clinical And Experimental Dentistry
Effect of Incorporating Date Seeds Microparticles on Compressive Strength and Microhardness of Conventional Glass Ionomer (an In Vitro Study)
...Show More Authors

View Publication
Scopus (2)
Crossref (2)
Scopus Crossref
Publication Date
Fri Jul 21 2023
Journal Name
Journal Of Engineering
FINITE ELEMENT ANALYSIS OF HUMAN AND ARTIFICIAL ARTICULAR CARTILAGE
...Show More Authors

Joint diseases, such as osteoarthritis, induce pain and loss of mobility to millions of people around the world. Current clinical methods for the diagnosis of osteoarthritis include X-ray, magnetic resonance imaging, and arthroscopy. These methods may be insensitive to the earliest signs of osteoarthritis. This study investigates a new procedure that was developed and validated numerically for use in the evaluation of cartilage quality. This finite element model of the human articular cartilage could be helpful in providing insight into mechanisms of injury, effects of treatment, and the role of mechanical factors in degenerative
conditions, this three-dimensional finite element model is a useful tool for understanding of the stress d

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sun Nov 02 2025
Journal Name
African Arguments
From Non‑Intervention to Non‑Indifference: What the African Union Has Really Learned about Crisis Management
...Show More Authors

Two decades after replacing the OAU, the AU’s record is best measured not by communiqués but by how fast it converts rules into results on the ground. In March 2022, the African Union’s Peace and Security Council (PSC) authorised the transition from AMISOM to ATMIS in Somalia — a reminder that, two decades after the African Union (AU) replaced the Organisation of African Unity (OAU), the Union’s rules are judged by execution, not intent. This article argues that the AU’s legal and institutional redesign shortened the warning‑to‑decision cycle and raised the credibility of enforcement, but performance still hinges on finance, logistics and political will. Where mandates are matched with money, enabling capabilities and enforc

... Show More
View Publication
Publication Date
Thu Dec 01 2011
Journal Name
Aes-atema International Conference Series - Advances And Trends In Engineering Materials And Their Applications
Effect of new tool geometry on weld strength of AA2024 aluminum alloy plates welded by friction stir spot welding process
...Show More Authors

A new tool geometry was used to achieve friction stir spot welding (FSSW) in which the shoulder was designed separately from the rotating pin, and in order to examine weldment strength through the modified tool, a lap joints of AA2024 aluminum alloy plate 1 mm thick were welded successfully by using 6 mm pin diameter and varying process parameters (rotational speeds, tool nose geometry, and depth of tool penetration in the lower welded plate). Experimental tests indicate that the maximum average tensile shear load was 3100 N at the best selected condition. Microstructure examination and micro hardness test along the spot zones were investigated as well as measuring pin penetration load. Visual inspection of the welded spot surface shows a g

... Show More
Scopus
Publication Date
Mon Jan 01 2018
Journal Name
International Journal Of Agricultural And Statistical Sciences
Production of potato under soilless culture
...Show More Authors

Scopus (7)
Scopus