A numerical method is developed to obtain two-dimensional velocity and pressure distribution through a cylindrical pipe with cross jet flows. The method is based on solving partial differential equations for the conservation of mass and momentum by finite difference method to convert them into algebraic equations. This well-known problem is used to introduce the basic concepts of CFD including: the finite- difference mesh, the discrete nature of the numerical solution, and the dependence of the result on the mesh refinement. Staggered grid implementation of the numerical model is used. The set of algebraic equations is solved simultaneously by “SIMPLE” algorithm to obtain velocity and pressure distribution within a pipe. In order to verify the validity for present code, the flow behavior predicted by this code is compared with these of another studies and there is a good agreement is obtained
In present study, the technique was used, including nuclear track detector type (CR-39), for appreciative concentrations uranium and radon in soil samples from Baghdad University Campus-AL-Jadiriyah utilizing a prolonged -term with a solid-state nuclear path sensor, a technique for charged particles has been developed., the radon concentrations, effective dose rate and uranium concentrations have measured in soil samples. Eight various venues from soil Baghdad University Campus have appointed. The results indicated variant values about uranium and radon concentrations, the average value for radon gas, effective dose rate and uranium concentrations was found to be 281.59 Bq/cm3, 7.09 mSv/y and 0.01 Bq/mm-2 respectively. All results a
... Show MoreThis study is planned to find relationship between interleukin-33 (IL-33) with its receptor interleukin-1 receptor 4 (IL-1R4), and assurance IL-33/IL-1R4 proportion as biomarker to atherosclerosisin rheumatoid arthritis (RA) Iraqi female’s patients with and without dyslipidemia. This study was attempted at Baghdad Teaching Hospital included 60 female’s patients with RA that were isolated into: 30 patients with dyslipidemia(G2), 30 patients without dyslipidemia(G3) and 30 individuals as control group (G1). Patients were experiencing treatment by methortexiene medication, analyzed by rheumatoid factor (RF) and erythrocyte sedimentation rate (ESR) tests. All patients and control groups age ranged from (30-55) years. The results show an inc
... Show MoreRetreatment Efficacy of Continuous Rotation Versus Reciprocation Kinematic Movements in Removing Gutta-Percha with Calcium Silicate-Based Sealer: SEM Study, Raghad Noori Nawaf*, Ra
A twisted-fin array as an innovative structure for intensifying the charging response of a phase-change material (PCM) within a shell-and-tube storage system is introduced in this work. A three-dimensional model describing the thermal management with charging phase change process in PCM was developed and numerically analyzed by the enthalpy-porosity method using commercial CFD software. Efficacy of the proposed structure of fins for performing better heat communication between the active heating surface and the adjacent layers of PCM was verified via comparing with conventional longitudinal fins within the same design limitations of fin material and volume usage. Optimization of the fin geometric parameters including the pitch, numb
... Show MoreThe study objective was to conduct Pharmacoeconomics study (cost-effective analysis) between infliximab reference (Remicade) and its biosimilar (Remsima) in patients with rheumatoid arthritis (RA) in Iraqi hospitals.
This is a retrospective multicenter pharmacoeconomic analysis conducted at two large teaching governmental hospitals in Baghdad, Iraq which provided infliximab to patients with RA. Data were collected from patient’s medical records and face-to-face interviews with the patients from December 2021 to April 2022.
The study included 57 patients with rheumatoid arthritis (RA). The patients were categorized into two groups according to the type of infliximab they received over 30 weeks: 27 patients received
... Show MoreA single step extraction-cleanup procedure using porous membrane-protected micro-solid phase extraction (μ-SPE) in conjunction with liquid chromatography–tandem mass spectrometry for the extraction and determination of aflatoxins (AFs) B1, B2, G1 and G2 from food was successfully developed. After the extraction, AFs were desorbed from the μ-SPE device by ultrasonication using acetonitrile. The optimum extraction conditions were: sorbent material, C8; sorbent mass, 20 mg; extraction time, 90 min; stirring speed, 1000 rpm; sample volume, 10 mL; desorption solvent, acetonitrile; solvent volume, 350 μL and ultrasonication period, 25 min without salt addition. Under the optimum conditions, enrichment factor of 11, 9, 9 and 10 for AFG2, AFG1
... Show More