The Effects of Inclination and Compounds Angles of Round Holes in Staggered Rows on Adiabatic Film Cooling Effectiveness of Vane Suction side
...Show More Authors

The aim of this work is oriented to increase film cooling effectiveness value through numerical investigations for flow of Mach number not more than 0.3 around vane surface, to find the effects of inclination and compounds angles of round holes in staggered rows on adiabatic film cooling effectiveness of vane suction side. Multi cylindrical film cooling hole cases were studied with pitch ratio P/d =2 and 3, local blowing ratios M=0.382, 0.77 and 1.14,  inclination angles a=30° and 45°, compound angles β= 0°, 15°, 30° and 45° and local momentum ratios I= 0.084, 0.34 and 0.756  for better cooling process.

            A numerical technique, using ANSYS-FLUENT version 14.5, was used to solve governing partial differential equations of mass, momentum (Navier Stokes equations) and energy conservations in three dimensions with a  turbulence model that involves the solution of the four transport equations. Based on the results of the numerical solution, the best film cooling configuration, blowing ratio, with the range of actual engine flow conditions, dimensions and vane geometry; density ratio 1.74 , temperature ratio 0.57 and blowing ratio M=0.382, 0.77 and 1.14 was obtained. The best case for inclination angle a=30°, P/d=2 was at M=1.14 and β=0° for the total average effectiveness along 60L/d of surface suction side was 0.616, while the best case for inclination angle a=45°, P/d=2 was at M=0.382 and β=30° for the total average effectiveness along 60L/d of surface suction side was 0.516.

            In addition, comparisons were performed with available other work, where the experimental total average effectiveness results of Dees et al., 2011 were in good agreements with the numerical results of current work with a maximum deviation of 9.9% at I=0.34 and 3.6% at I=0.75.

 

 

View Publication Preview PDF
Quick Preview PDF
Publication Date
Wed Sep 30 2009
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Extraction of medicinal compounds from botanicals using bulk liquid membrane in rotating film contactor: Recovery of vinblastine from catharanthus roseus.
...Show More Authors

The interest of application of liquid membrane (pertraction) processes for recovery of medicinal compounds from dilute ammoniacal leach solutions is demonstrated. Selectivity of the liquid membrane ensures a preferential transport of the desired solute from the native extract into the strip solution, vinblastine was successfully extracted from basic media (pH 9.2) and stripped by acidic media of sulfuric acid (pH= 1.3) applying continuous pertraction in a rotating discs contactor and using n-decane as liquid membrane. Transport of vinblastine in three-liquid-phase system was studied and performed by means of a kinetic model involving two consecutive irreversible first-order reactions. The kinetic parameters (apparent rate constants of th

... Show More
View Publication Preview PDF
Publication Date
Sun Sep 01 2024
Journal Name
Baghdad Science Journal
Isolation and Identification of Flavonoid Compounds from Euphorbia Milii Plant Cultivated in Iraq and Evaluation of its Genetic Effects on Two Types of Cancer Cell Line
...Show More Authors

يعتبر "تاج الأشواك" أو نبات شوكة المسيح، وهو من نباتات الزينة الطبية ، ينتمي إلى جنس يوفوربيا. E. milii يحتوي كميات وفيرة من المركبات الفينولية ، التربينات، الستيرويدات والقلويدات. كانت الأهداف الرئيسية لهذه الدراسة هي فحص مستخلصات الفلافونويد والنانو فلافونويد ضد نوعين من خطوط الخلايا السرطانية. تم تصنيع مركبات الفلافونويد النانوية عن طريق تفاعل مركب الكيتوسان والماليك اسد. تم تحليل مركبات الفلافونويد ال

... Show More
Scopus (1)
Scopus Clarivate Crossref
Publication Date
Sun Jun 11 2017
Journal Name
Al-academy
Shape of Round house as an Effective Strategy in the Collection of Art Education Students
...Show More Authors

The two researchers selected the problem of research which represented with the following asking: Does the use of the shape of Round house strategy have effectiveness in the collection of students of the Department of Art Education of the subjectof teaching methods?
The research aims to "measure the effectiveness of Strategy shape of Round house in the collection of students of the Department of Art Education for the material teaching methods" and to verify the aim of the research two zeroassumptions was identified to measure the level of achievement in the subject of teaching methods of third stage students in the Department of Art Education –College of Fine Arts.
The research community included the students of Art Education Dep

... Show More
View Publication Preview PDF
Crossref
Publication Date
Tue Nov 04 2025
Journal Name
Modern Sport
The effect of Developing special endurance using multiple round periods on some physical and functional indicators for elite boxers
...Show More Authors

View Publication Preview PDF
Publication Date
Fri Dec 01 2023
Journal Name
Iranian Journal Of Medical Microbiology
Detection of Biologically Active Compounds in <i>Eriobotrya japonica</i> L. Seeds Extract and Determination of Their Effectiveness Against Dermatophytes
...Show More Authors

View Publication
Scopus Crossref
Publication Date
Thu Dec 01 2011
Journal Name
Journal Of Engineering
THEORETICAL AND EXPERIMENTAL STUDY ON THERMAL PERFORMANCE OF CLOSED WET COOLING TOWER
...Show More Authors

Thermal performance of closed wet cooling tower has been investigated experimentally and theoretically
in this work. The theoretical model based on heat and mass transfer equations and heat and mass transfer balance equations which are established for steady state case. A new small indirect cooling tower was used for conducting experiments. The cooling capacity of cooling tower is 1 kW for an inlet water temperature of 38oC, a water mass velocity 2.3 kg/m2.s and an air wet bulb temperature of 26oC. This study investigates the relationship between saturation efficiency, cooling capacity and coefficient of performance of closed wet cooling tower versus different operating parameters such wet-bulb temperature, variable air-spray water fl

... Show More
View Publication Preview PDF
Crossref
Publication Date
Fri Mar 01 2019
Journal Name
Al-khwarizmi Engineering Journal
Mass-Transfer Characteristics of Air- Suction Type Fermentors
...Show More Authors

Liquid-side mass-transfer coefficients (KLa) were measured in air-suction type fermentors using physical absorption of oxygen.  A fermentor of 0. 5 m i.d. was used with a working capacity of 60 liters of liquid. Tap water was used as the liquid phase, and air was used as the gas phase. The bioreactor mixing system consists of shrouded-disk/curved-blade turbine with six evacuated bending blades. The effect of liquid submergence (S) was investigated. Further, the effects of the ratio of the impeller diameter (D) to the tank diameter (T), and the clearance of the impeller from the tank bottom(C) were also studied.  The agitation speed (N) was varied in the range of 50-800 rpm. It was found that the value of  K

... Show More
View Publication Preview PDF
Publication Date
Sat Dec 31 2011
Journal Name
Al-khwarizmi Engineering Journal
Effect of Mixed Corrosion Inhibitors in Cooling Water System
...Show More Authors

The effect of mixed corrosion inhibitors in cooling system was evaluated by using carbon steel specimens and weight loss analysis. The carbon steel specimens immersed in mixture of sodium phosphate (Na2 HPO4) used as corrosion inhibitor and sodium glocunate (C6 H11 NaO7) as a scale dispersant at different concentrations (20,40, 60, 80 ppm) and at different temperature (25,50,75 and 100)ºC for (1-5) days. The corrosion inhibitors efficiency was calculated by using uninhibited and inhibited water to give 98.1%. The result of these investigations indicate that the corrosion rate decreases with the increase the corrosion inhibitors concentration at 80 ppm and at 100ºC for 5 days, (i.e,

... Show More
View Publication Preview PDF
Publication Date
Tue Jan 01 2019
Journal Name
Aip Conference Proceedings
Effect of in on the properties of AlSb thin film solar cell
...Show More Authors

View Publication
Scopus (15)
Crossref (5)
Scopus Clarivate Crossref
Publication Date
Sun Feb 24 2019
Journal Name
Iraqi Journal Of Physics
Construction and performance study of a solar - powered hybrid cooling system in Iraq
...Show More Authors

The systems cooling hybrid solar uses solar collector to convert solar energy into the source of heat for roasting Refrigerant outside of the compressor and this process helps in the transformation of Refrigerant from the gas to a liquid state in two-thirds the top of the condenser instead of two-thirds the bottom of the condenser as in Conventional cooling systems and this in turn reduces the energy necessary to lead the process of cooling. The system cooling hybrid use with a capacity of 1 ton and Refrigerant type R22 and the value of current drawn by the system limits (3.9-4.2A), the same value of electric current calculated by the system are  Conventional  within this atmosphere of Iraq, and after taking different readings

... Show More
View Publication Preview PDF
Crossref