Preferred Language
Articles
/
ijp-372
Construction and performance study of a solar - powered hybrid cooling system in Iraq
...Show More Authors

The systems cooling hybrid solar uses solar collector to convert solar energy into the source of heat for roasting Refrigerant outside of the compressor and this process helps in the transformation of Refrigerant from the gas to a liquid state in two-thirds the top of the condenser instead of two-thirds the bottom of the condenser as in Conventional cooling systems and this in turn reduces the energy necessary to lead the process of cooling. The system cooling hybrid use with a capacity of 1 ton and Refrigerant type R22 and the value of current drawn by the system limits (3.9-4.2A), the same value of electric current calculated by the system are  Conventional  within this atmosphere of Iraq, and after taking different readings of the temperatures and pressure to several points in the system's found that the Refrigerant when it comes out of the compressor, it loses part of the temperature of the water in the solar collector through a heat exchanger while the literature published in accordance with the manufacturers that the solar collector, a kind of vacuum tubes contributes to raise the pressure and temperature of the fluid cooler to reduce the consumption of energy spent on compressor. Therefore, the system described by the current not fit for domestic use within the Iraqi environmental conditions.

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Mon Oct 01 2018
Journal Name
Journal Of Engineering
Experimental Study of Hybrid Solar Air Conditioning System in Iraq
...Show More Authors

In this paper, an experimental study of the thermal performance for hybrid solar air conditioning system was carried out, to investigate system suitability for the hot climate in Iraq. The system consists of vapor compression unit combined with evacuated tube solar collector and liquid storage tank. A three-way valve was installed after the compressor to control the direction flow of the refrigerant, either to the storage tank or directly to the condenser. The performance parameters were collected by data logger to display and record in the computer by using LabVIEW software. The results show that the average coefficient of performance of hybrid solar air conditioning system (R=1) was about 2.42 to 2.77 and the average p

... Show More
View Publication Preview PDF
Crossref (2)
Crossref
Publication Date
Wed Jun 01 2022
Journal Name
Baghdad Science Journal
Design and Performance Investigation of a Solar- Powered Biological Greywater Treatment System in the Iraqi Climate
...Show More Authors

            The increase in population resulted in an increase in the consumption of water. The present work investigates the performance of a recycling solar- powered greywater treatment system for the purposes of irrigation, used to reduce the amount of waste grey water and reduce electricity consumption and reduce the costs of constructing large scale water treatment plants. The system consumes about 3814W per hour and provides water treatment about 1.4 m3 per day. The proposed system is designed to    residential, office and governmental buildings application. Tests are conducted in an office building at the Ministry of Science and Technology site in Baghdad. Laboratorial water samples testing analyses are co

... Show More
View Publication Preview PDF
Scopus Clarivate Crossref
Publication Date
Sat Jul 01 2023
Journal Name
Journal Of Engineering
Performance of Solar Adsorption Cooling System Using Methanol and Activated Carbon as a Working Pair
...Show More Authors

The need for renewable energy sources is higher than ever due to rising global warming, climate change, and ozone depletion. For refrigeration and air conditioning applications, adsorption refrigeration systems are viable alternatives cooling techniques. This study is a topic and part of the M.Sc. thesis. A field solar-powered ice maker unit was created, studied, tested, and evaluated on the 13th and 30th of May, 2022. Activated carbon and methanol pair was used to set up a refrigeration system in Baghdad (Al Dora). Experimental tests were carried out outdoors to determine the coefficient of performance COP and specific cooling power SCP of the system. The results showed that the lowest temperature

... Show More
View Publication Preview PDF
Crossref (2)
Crossref
Publication Date
Fri Jul 21 2023
Journal Name
Journal Of Engineering
Cooling and Heating a Greenhouse in Baghdad by a Solar Assisted Desiccant System
...Show More Authors

Modeling the microclimate of a greenhouse located in Baghdad under its weather conditions to calculate the heating and cooling loads by computer simulation. Solar collectors with a V-corrugated absorber plate and an auxiliary heat source were used as a heating system. A rotary silica gel desiccant dehumidifier, a sensible heat exchanger, and an evaporative cooler were added to the collectors to form an open-cycle solar assisted desiccant cooling system. A dynamic model was adopted to predict the inside air and the soil surface temperatures of the greenhouse. These temperatures are used to predict the greenhouse heating and cooling loads through an energy balance method which takes into account the soil heat gain. This is not included in

... Show More
View Publication Preview PDF
Crossref (3)
Crossref
Publication Date
Sat Mar 30 2013
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Studying the Performance of Refrigeration Units Powered by Solar Panel
...Show More Authors

An experimental study was conducted to determine the performance of a solar electric refrigeration system. The system contained flat photovoltaic solar panel which absorbs the solar energy and convert it to electrical energy, used to run the refrigeration cycle. Two refrigeration cycles with electrical solar panel were used over a period of 12 months, the first one with classical parts known in refrigeration cycle, while the second one introduced heat exchanger which improves the coefficient of performance by saving the consumed energy. The coefficient of performance of these refrigeration cycles with compressor efficiency 85% are 2.102 and 2.57 respectively. The overall efficiency of the two systems are 18.9% and 23.13%.

View Publication Preview PDF
Publication Date
Sun Mar 01 2015
Journal Name
Baghdad Science Journal
Performance evolution of a hybrid thermal solar air conditioning system and compare it with a traditional system according to Iraq weather
...Show More Authors

In a hybrid cooling solar thermal systems , a solar collector is used to convert solar energy into heat energy in order to super heat the refrigerant leaving the compressor, and this process helps in the transformation of refrigerant state from gaseous state to the liquid state in upper two-thirds of the condenser instead of the lower two-thirds such as in the traditional air-conditioning systems and this will reduce the energy needed to run the process of cooling .In this research two systems with a capacity of 2 tons each were used, a hybrid air-conditioning system with an evacuated tubes solar collector and a traditional air-conditioning system . The refrigerant of each type was R22.The comparison was in the amou

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sat Oct 16 2021
Journal Name
Energies
Performance Analysis of a Solar Cooling System with Equal and Unequal Adsorption/Desorption Operating Time
...Show More Authors

In solar-thermal adsorption/desorption processes, it is not always possible to preserve equal operating times for the adsorption/desorption modes due to the fluctuating supply nature of the source which largely affects the system’s operating conditions. This paper seeks to examine the impact of adopting unequal adsorption/desorption times on the entire cooling performance of solar adsorption systems. A cooling system with silica gel–water as adsorbent-adsorbate pair has been built and tested under the climatic condition of Iraq. A mathematical model has been established to predict the system performance, and the results are successfully validated via the experimental findings. The results show that, the system can be operational

... Show More
View Publication
Scopus (10)
Crossref (9)
Scopus Clarivate Crossref
Publication Date
Mon Jul 10 2023
Journal Name
Journal Of Engineering
Theoretical Evaluation of Solar Assisted Desiccant Cooling System for a Small Meeting-Hall
...Show More Authors

The performance of a solar assisted desiccant cooling system for a meeting-hall located in the College of Engineering/University of Baghdad was evaluated theoretically. The system was composed of four components; a solar air heater, a desiccant dehumidifier, a heat exchanger and an evaporative cooler. A computer simulation was developed by using MATLAB to assess the effect of various design and operating conditions on the performance of the system and its components. The actual weather data on recommended days were used to assess the load variation and the system performance during those days. The radiant time series method (RTS) was used to evaluate the hourly variation of the cooling load. Four operation modes were employed for perform

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sun Jun 07 2015
Journal Name
Baghdad Science Journal
The effect of changing the evacuated tube tilt angle and the fluid of the solar collector on the performance of a hybrid solar air conditioning system
...Show More Authors

In the hybrid coolingsolar systems , a solar collectoris used to convertsolar energy intoheat sourcein order to super heat therefrigerant leave thecompressor,andthisprocess helpsin the transformation ofrefrigerant state from gaseous statetothe liquid statein upper two-thirdsof thecondenserinstead of the lower two-thirdssuchas in thetraditional air-conditioning systems and this willreduce theenergyneeded torun the process ofcooling.In this research two hybrid air-conditioning system with an evacuated tube solar collector were used, therefrigerant was R22 and the capacity was 2 tons each.The tilt angle of the evacuated tube solar collector was changed and the solar collector fluid was replaced into oil instead of water.A comparison wasi

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sun Jul 09 2023
Journal Name
Journal Of Engineering
Solar Powered Air-Conditioning Using Absorption Refrigeration Technique
...Show More Authors

The present work includes design, construction and operates of a prototype solar absorption refrigeration system, using methanol as a refrigerant to avoid any refrigerant that cause global warming and greenhouse effect. Flat plate collector was used because it’s easy, ninexpensive and efficient. Many test runs (more than 50) were carried out on the system from May to October, 2013; the main results were taken between the period of July 15, 2013 to August 15, 2013 to find the maximum C.O.P, cooling, temperature and pressure of the system. The system demonstrates a maximum generator temperature of 93.5 oC, on July 18, 2013 at 2:30 pm, and the average mean generator temperature Tgavr was 74.7 °C, for this period. The maximum pressure Pg

... Show More
View Publication Preview PDF
Crossref (2)
Crossref