In this paper, variable gain nonlinear PD and PI fuzzy logic controllers are designed and the effect of the variable gain characteristic of these controllers is analyzed to show its contribution in enhancing the performance of the closed loop system over a conventional linear PID controller. Simulation results and time domain performance characteristics show how these fuzzy controllers outperform the conventional PID controller when used to control a nonlinear plant and a plant that has time delay.
In real situations all observations and measurements are not exact numbers but more or less non-exact, also called fuzzy. So, in this paper, we use approximate non-Bayesian computational methods to estimate inverse Weibull parameters and reliability function with fuzzy data. The maximum likelihood and moment estimations are obtained as non-Bayesian estimation. The maximum likelihood estimators have been derived numerically based on two iterative techniques namely “Newton-Raphson†and the “Expectation-Maximization†techniques. In addition, we provide compared numerically through Monte-Carlo simulation study to obtained estimates of the parameters and reliability function i
... Show MoreIn this paper, a procedure to establish the different performance measures in terms of crisp value is proposed for two classes of arrivals and multiple channel queueing models, where both arrival and service rate are fuzzy numbers. The main idea is to convert the arrival rates and service rates under fuzzy queues into crisp queues by using graded mean integration approach, which can be represented as median rule number. Hence, we apply the crisp values obtained to establish the performance measure of conventional multiple queueing models. This procedure has shown its effectiveness when incorporated with many types of membership functions in solving queuing problems. Two numerical illustrations are presented to determine the validity of the
... Show MoreThis paper includes a comparison between denoising techniques by using statistical approach, principal component analysis with local pixel grouping (PCA-LPG), this procedure is iterated second time to further improve the denoising performance, and other enhancement filters were used. Like adaptive Wiener low pass-filter to a grayscale image that has been degraded by constant power additive noise, based on statistics estimated from a local neighborhood of each pixel. Performs Median filter of the input noisy image, each output pixel contains the Median value in the M-by-N neighborhood around the corresponding pixel in the input image, Gaussian low pass-filter and Order-statistic filter also be used.
Experimental results shows LPG-
... Show MoreThis paper includes a comparison between denoising techniques by using statistical approach, principal component analysis with local pixel grouping (PCA-LPG), this procedure is iterated second time to further improve the denoising performance, and other enhancement filters were used. Like adaptive Wiener low pass-filter to a grayscale image that has been degraded by constant power additive noise, based on statistics estimated from a local neighborhood of each pixel. Performs Median filter of the input noisy image, each output pixel contains the Median value in the M-by-N neighborhood around the corresponding pixel in the input image, Gaussian low pass-filter and Order-statistic filter also be used. Experimental results shows LPG-PCA method
... Show MoreThe process of self-assessment plays a key role in achieving quality educational institutions (college, department or program academic particular), because the assessment process provides reviews of the effectiveness of the criteria used in the enterprise, especially in the field of teaching and learning, and is result self-assessment providing self-assessment report. The self- assessment can be performed at different levels (college, academic department, Master, Ph.D. program, or courses). The importance of the research focused on to provide a measure of self-assessment helps profile officials in the implementation of the assessment process are clear and precise and fast, and to provide them to measure the availability requireme
... Show MoreIn this paper, a sufficient condition for stability of a system of nonlinear multi-fractional order differential equations on a finite time interval with an illustrative example, has been presented to demonstrate our result. Also, an idea to extend our result on such system on an infinite time interval is suggested.
The research aims to identify the effect of applying administrative decentralization to an educational performance by assessing educational performance before and after the process of transferring powers from the federal government (the Iraqi Ministry of Education) to local governments (governorates) as well as identifying the appropriate central or decentralized administrative system to advance the educational reality and performance. To achieve the goal of the research, educational data was collected and analyzed, as well as the measurement of educational performance indicators and analysis during two phases, the first represents the stage of applying the central system and spanned between the academic year (2011-2012) and the
... Show MoreThe study is concern on determine the type of Candida spp.in leukemia patients that were infected with oral candidiasis as a result to their immune suppression (weekend immune system) due to their submission to radiation and chemotherapy treatment. The result showed that the most common isolates were C. guillermondii 19 which represent 31.66% of cases, then followed by C. itermedia 11 which represent 18.3%, while the less common isolates were for C. zeylamodes 3 which represent 5%.
During the winter, in the industry region (Shaikh Omer) and by applying a passive radon detector (CR-39), lung cancer risk has been measured in twelve rooms of different workshops of two old factories in this site. The radon concentration is ranged from (123.345 Bq/m3) to (328.985 Bq/m3) with an average of (244.19±61.52 Bq/m3). Lung cancer risk ranged from 55.993 to 149.346 per million people and with an average of (110.855 per million people) which were lower than the recommended values (170-230 per million people), so there was no cancer risk on workers in these locations.