The aim of this work is to perform an experimental study for the effect of forced vertical vibrations on free convection heat transfer coefficient, from flat plate made of Aluminum with dimension (300 Length*100 Width*3 thickness mm).It's heated under a constant heat flux of (250-1500 W/m2 ) upward. The flat plate was located horizontally or inclined in multiple angles at rang of (0o , 30o , 45o 60o ، 90o ). The experimental study is carried out at a range of frequency (2-16 Hz) ، the amplitude at the range of (1.63-7.16 mm), and the Rayleigh number at the rang (138.991< Ra <487.275).
The results of this study show that, the relation between the heat transfer coefficient and the amplitude of vibration is incrementally for inclination angles from (0°-60°), and reaches a maximum ratio of (13%) in the horizontal position, except at the vertical position (θ=90o ) the heat transfer coefficient decreases as the vibration response increases and the maximum decrease ratio occurs at (7.6 %)
The research aims to shed light on the amount of proceeds annual tax for each of the way the contract total and percentage of completion method - see which is better - as well as the current problems arising from the application method of the contract in full in settling accounts tax - to identify problems - related to postpone settling accounts tax in accordance with the way the contract fully and determine the advantages and disadvantages of each of the methods through practical application , and then use the results as inputs to help in the decision to confirm the continuation of the GCT using a full decade in settling accounts tax for long-term construction contracts or forgo them.
Were the result of research the existence of