The ejector refrigeration system is a desirable choice to reduce energy consumption. A Computational Fluid Dynamics CFD simulation using the ANSYS package was performed to investigate the flow inside the ejector and determine the performance of a small-scale steam ejector. The experimental results showed that at the nozzle throat diameter of 2.6 mm and the evaporator temperature of 10oC, increasing boiler temperature from 110oC to 140oC decreases the entrainment ratio by 66.25%. At the boiler temperature of 120oC, increasing the evaporator temperature from 7.5 to 15 oC increases the entrainment ratio by 65.57%. While at the boiler temperature of 120oC and the evaporator temperature of 10oC, increasing the nozzle throat diameter from 2.4 to 2.8 mm decreases the entrainment ratio by 40%. The numerical results showed that reducing the condenser back pressure or increasing the primary fluid temperature, secondary fluid temperature, and nozzle throat diameter moves the second shock waves in the downstream direction. It could be concluded that the second shock series position detects the ejector operation mode. The ejector runs in critical mode if the second shock series position is close to the diffuser. In contrast, if the second shock series position moves toward the upstream, the ejector runs in subcritical mode.
The hydrological process has a dynamic nature characterised by randomness and complex phenomena. The application of machine learning (ML) models in forecasting river flow has grown rapidly. This is owing to their capacity to simulate the complex phenomena associated with hydrological and environmental processes. Four different ML models were developed for river flow forecasting located in semiarid region, Iraq. The effectiveness of data division influence on the ML models process was investigated. Three data division modeling scenarios were inspected including 70%–30%, 80%–20, and 90%–10%. Several statistical indicators are computed to verify the performance of the models. The results revealed the potential of the hybridized s
... Show MoreThe present work investigates the effect of magneto – hydrodynamic (MHD) laminar natural convection flow on a vertical cylinder in presence of heat generation and radiation. The governing equations which used are Continuity, Momentum and Energy equations. These equations are transformed to dimensionless equations using Vorticity-Stream Function method and the resulting nonlinear system
of partial differential equations are then solved numerically using finite difference approximation. A thermal boundary condition of a constant wall temperature is considered. A computer program (Fortran 90) was built to calculate the rate of heat transfer in terms of local Nusselt number, total mean Nusselt number, velocity distribution as well as te
Banks face different types of banking risks that limit the performance of its functions and achieve its objectives, including the financial risk that is based on current research into two types including a credit and liquidity risks. And established credit risk due to the possibility of delaying the borrowers to fulfill their obligations to the bank when due or non-payments on according to the terms agreed upon, while liquidity risk arises as a result of the inability of the bank to fund the financial needs, any inability to provide cash to pay its obligations short on credit without achieving tangible loss or the inability to employ the funds properly and show the liquidity risk in the event of inadequate cash inflows to the bank for an
... Show MoreNanocomposite films of silver-polyvinyl alcohol (Ag/PVA) with varying silver nanoparticle concentrations (1-5 wt%) were synthesized via a solution casting technique. The films were characterized by understanding the influence of Ag content on their structural, optical, mechanical, and electrical properties. UV-Vis spectroscopy (300-800 nm) revealed a red shift in absorption peaks and a significant decrease in the optical band gap from 5.39 eV to 1.06 eV with increasing Ag concentration, indicating the formation of additional energy states within the PVA matrix. FTIR and SEM analyses confirmed the successful incorporation of nanoparticles and revealed changes in surface functionalities and morpholog
Pressure ulcers are one of the most common hospital-acquired major conditions that occur in patients with mobility limitations and result in endangering patient safety, prolonging hospital stay, disability, and death. This study aims to examine the level of nurses’ practices and perceived barriers for preventing pressure ulcers among critically ill patients.
A cross-sectional survey was conducte
In the presence of deep submicron noise, providing reliable and energy‐efficient network on‐chip operation is becoming a challenging objective. In this study, the authors propose a hybrid automatic repeat request (HARQ)‐based coding scheme that simultaneously reduces the crosstalk induced bus delay and provides multi‐bit error protection while achieving high‐energy savings. This is achieved by calculating two‐dimensional parities and duplicating all the bits, which provide single error correction and six errors detection. The error correction reduces the performance degradation caused by retransmissions, which when combined with voltage swing reduction, due to its high error detection, high‐energy savings are achieved. The res