Preferred Language
Articles
/
joe-1926
ESTIMATION OF THE OPTIMUM BED THICKNESS OF A FLOWTHROUGH POROUS ELECTRODE (FTPE) WORKING UNDER MASS TRANSFER CONTROL
...Show More Authors

In this paper, a theoretical analysis of optimum bed thickness operates under mass transfer control for realizing a high efficiency and reaction conversion of an electrochemical reactor has been made based on flowthrough porous electrode (FTPE) configuration. Many models have been used to represent the optimum bed thickness by taking a look into previous works concerned and collecting all related information, data, and models. The parameters that affect the optimum bed thickness have been visualized and reviewed, and almost all of them have been examined by experimental data from different sources and based on the various models. It has been found that the increase in electrolyte flow rate, concentration, limiting current density, and specific surface area reduce the optimum bed thickness, and the increase in electrolyte conductivity, void fraction, and overpotential range increases optimum bed thickness. The most important design parameter that has a great effect on optimum bed thickness is found to be the electrolyte flow rate for any certain operation. It has been concluded that the most appropriate two models to represent the optimum bed thickness of FTPE electrochemical reactor operating under mass transfer control based on the results are those predicted theoretically and stated by Kreysa in (1978) and Doherty et al. in (1996). 

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Tue Aug 03 2021
Journal Name
Key Engineering Materials
Study the Behavior of Castellated Steel Column Encasing by Different Reactive Powder Concrete Thickness with Laced Reinforcement
...Show More Authors

Castellated columns are structural members that are created by breaking a rolled column along the center-line by flame after that rejoining the equivalent halves by welding such that for better structural strength against axial loading, the total column depth is increased by around 50 percent. The implementation of these institutional members will also contribute to significant economies of material value. The main objectives of this study are to study the enhancement of the load-carrying capacity of castellated columns with encasement of the columns by Reactive Powder Concrete (RPC) and lacing reinforcement, and serviceability of the confined castellated columns. The Castellated columns with RPC and Lacing Reinforcement improve com

... Show More
View Publication
Scopus (2)
Crossref (2)
Scopus Crossref
Publication Date
Fri Apr 01 2022
Journal Name
Separation And Purification Technology
Application of central composite design approach for optimisation of zinc removal from aqueous solution using a Flow-by fixed bed bioelectrochemical reactor
...Show More Authors

View Publication
Scopus (20)
Crossref (16)
Scopus Clarivate Crossref
Publication Date
Fri Apr 01 2022
Journal Name
Separation And Purification Technology
Application of central composite design approach for optimisation of zinc removal from aqueous solution using a Flow-by fixed bed bioelectrochemical reactor
...Show More Authors

View Publication
Scopus (20)
Crossref (16)
Scopus Clarivate Crossref
Publication Date
Sun Feb 05 2017
Journal Name
Iraqi Journal Of Market Research And Consumer Protection
STUDY THE OPTIMUM CONDITIONS FOR THE REMOVAL OF HEAVY METAL ELEMENTS FROM AQUEOUS SOLUTIONS USING CONTAMINATED BACTERIA Bacillus subtilis LOCALLY ISOLATED: STUDY THE OPTIMUM CONDITIONS FOR THE REMOVAL OF HEAVY METAL ELEMENTS FROM AQUEOUS SOLUTIONS USING CONTAMINATED BACTERIA Bacillus subtilis LOCALLY ISOLATED
...Show More Authors

We studied the effect of certain environmental conditions for removing heavy metal elements from contaminated aqueous solutions (Cd, Cu, Pb, Fe, Zn, Ni, Cr) using the bacterium Bacillus subtilis to appoint the optimal conditions for removal ,The best optimum temperature range for two isolate was 30-35○C while the hydrogen number for the maximum mineral removal range was 6-7. The best primary mineral removal was 100 mg/L, while the maximum removal for all minerals was obtained after 6 hrs of Cu element time and the maximum removal efficiency was obtained after 24 hrs of Cu element. The results have proved that the best aeration for maximum removal was obtained at rotation speed of 150 rpm/minute. Inoculums of 5ml/100ml which contained 1

... Show More
View Publication Preview PDF
Publication Date
Tue Aug 15 2023
Journal Name
Bionatura
Gene expression of a nitrogen tolerance gene ZmNR1 under the influence of different levels of nitrogen in maize
...Show More Authors

A field experiment was carried out in the College of Agricultural Engineering Sciences - University of Baghdad, during the fall season of 2021 to find out which cultivated cultivars of maize are efficient under nitrogen fertilization. The experiment was applied according to an RCBD (split-plot design with three replications). The cultivars of the experiment (Baghdad, 5018, Sarah) supply three levels of nitrogen fertilizer, which are N1 (100 kg.N/ha), N2 (200 kg.N/ha) and N3 (300 kg.N/ha). The statistical analysis results showed the superiority of the Sarah genotype, which gave the highest value of SOD and CAT enzymes, reaching 11.59 units mg-1 and 10.76 units mg-1 . Protein sequentially, while cultivar5018 outperformed as it gave th

... Show More
View Publication
Scopus (15)
Crossref (11)
Scopus Crossref
Publication Date
Tue Dec 30 2014
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Heat Transfer Efficiency of Different Composite Insulators
...Show More Authors

This research aims to investigate the thermal performance of different thermal composite insulators, wrapped around a closed-loop copper pipe (CLP). To achieve this aim a system was designed and manufactured. It is consisted of closed water tank insulated by Rock Wool, and supplied with two electric heaters, two thermostat, a flow meter, a water pump, digital temperature scales, and four series of (CLP).
Six insulators were prepared namely; composites of Impregnated Fiberglass with Elastoclad and foaming Rubber (FER), Impregnated Fiberglass with Elastoclad resin and Polymeric Membrane (FEM), Impregnated Fiberglass with Polyurethane thermoset resin and Foaming Rubber (FUR), Impregnated Fiberglass with Polyurethane thermoset resin and P

... Show More
View Publication Preview PDF
Publication Date
Sun Jan 08 2023
Journal Name
Journal Of Planner And Development
Measuring the extent to which Application the criteria Transfer stations (regularity) for the municipalities of Karrada and Shula
...Show More Authors

The process of transporting waste from urban areas to sanitary landfill sites requires large amounts of money due to the length and distance. To address this problem, temporary transfer stations were established by the Municipality of Baghdad to reduce the cost of transportation, and for the purpose of preserving the environment in a sustainable manner, standards were set for the establishment of these stations. The two stations of Al-Karrada Municipality and Al-Shula Municipality were chosen as a case study to measure the extent of adopting and applying the standards for establishing substations locally, regionally and internationally, and the most important results were reached Which is that the transforming (regular) stations of the t

... Show More
View Publication Preview PDF
Publication Date
Tue Dec 01 2020
Journal Name
Periodicals Of Engineering And Natural Sciences
Constructing a new mixed probability distribution with fuzzy reliability estimation
...Show More Authors

This paper deals with constructing mixed probability distribution from mixing exponential

Scopus (6)
Scopus
Publication Date
Thu Feb 27 2020
Journal Name
Journal Of Mechanics Of Continua And Mathematical Sciences
A FUZZY PID CONTROLLER MODEL USED IN ACTIVE SUSPENSION OF THE QUARTER VEHICLE UNDER MATLAB SIMULATION
...Show More Authors

View Publication
Crossref (2)
Crossref
Publication Date
Tue Sep 01 2020
Journal Name
Journal Of Engineering
Experimental Study on Heat Transfer and Flow Characteristics in Subcooled Flow Boiling in a Microchannel
...Show More Authors

The current study presents an experimental investigation of heat transfer and flow characteristic for subcooled flow boiling of deionized water in the microchannel heat sink. The test section consisted of a single microchannel having 300μm wide nominal dimensions and 300μm height (hydraulic diameter of 300μm). The test section formed of oxygen-free copper with 72mm length and 12mm width. Experimental operation conditions spanned the heat flux (78-800) kW/m2, mass flux (1700 and 2100) kg/m2.s at 31˚C subcooled inlet temperature. The boiling heat transfer coefficient is measured and compared with existing correlations. Also, the experimental pressure drop is measured and compared with microscale p

... Show More
View Publication Preview PDF
Crossref (2)
Crossref