Preferred Language
Articles
/
joe-1836
Effect of Surface Pavement Type on Traffic Noise
...Show More Authors

This paper investigates the issue of surface-type effects on traffic noise in Baghdad. Since the raw materials for both flexible and rigid paving are available from local sources, the decision on selecting the type of paving which depends on the budget of the project and the road's importance and function. Knowing that for high traffic volumes and a high percentage of heavy vehicles, rigid pavement is more suitable compared to flexible pavement. In Baghdad, some highways consist of flexible pavement and others of combined pavement (flexible segments and rigid segments), so the study of the effect of surface type on traffic noise becomes an important matter. This study selected three highways: one with flexible pavement and two with the combined pavement. The results showed that the traffic noise generated by traffic on rigid pavement generates more noise than traffic on flexible pavement by about 2 dBA. A prediction model was generated to predict traffic noise depending on five variables (vehicle speed, traffic volume, skid number, distance between the edge of the inner lane and the sound level meter, and surface type). The measured traffic noise levels ranged from 73.23 to 82.86 dBA, which exceeded the permitted limits compared to the permissible Iraqi standards.

 

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Wed Jun 11 2025
Journal Name
Journal Of Baghdad College Of Dentistry
Surface area measurements of upper dental cast with different final impressionss
...Show More Authors

Background : surface area anatomy is a proportional point to the retention of complete denture, in past there was no quantitative method to evaluate the surface area, nowadays the size and shape of maxillary arch is measured by different electronically and mathematical devices. A study was therefore, undertaken to measure surface area of upper dental cast that was taken by different final impressions. Materials and methods: twenty patients were examined. All of them had a healthy palate with no singe of injury, trauma, or deformity. Casts were taken by three different final impressions; zinc oxide, additional silicon, and poly ether. And two different devices were used; the computerized one and the Aluminum foil measure. Age, se

... Show More
View Publication Preview PDF
Publication Date
Sat Jul 22 2023
Journal Name
Journal Of Engineering
Removal of Boron from Simulated Iraqi Surface Water by Electrocoagulation Method
...Show More Authors

The removal of boron from aqueous solution was carried out by electrocoagulation (EC) using magnesium electrodes as anode and stainless steel electrodes as cathode. Several operating parameters on the removal efficiency of boron were investigated, such as initial pH, current density, initial boron ion concentration, NaCl concentration, spacing between electrodes, electrode material, and presence of carbonate concentration. The optimum removal efficiency of 91. 5 % was achieved at a current density of 3 mA/cm² and  pH = 7 using (Mg/St. St. ) electrodes, within 45 min of operating time. The concentration of NaCl was o. 1 g/l with a 0.5cm spacing between the electrodes. First and second order rate equation were applied to study adsorp

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Fri Aug 20 2021
Journal Name
Iraqi Journal Of Laser
Pulsed Er,Cr:YSGG Laser For Surface Modification of Dental Zerconia Ceramic
...Show More Authors

Background: Surface treatment of machined dental zirconia for enhancement of the adhesion to resin cement, using Er,Cr:YSGG  Laser. Materials and Methods: Total number of 42 zirconia disc specimens (9 mm diameter, and 2 mm height) was sintered according to the manufacturer instruction. They are divided into six groups, each group of seven samples. Laser groups (Experiment parameters) were depend on laser total irradiation time, pulse duration, and power. Group (A): 20 sec., 60 µs pulse duration. Group (B): 30 sec., 60 µs pulse duration. Group (C): 40 sec., 60 µs pulse duration. Group (D): 20 sec., 700 µs pulse duration. Group (E): 30 sec., 700 µs pulse duration, with different powers used (1, 1

... Show More
View Publication Preview PDF
Publication Date
Fri Jan 20 2023
Journal Name
Ibn Al-haitham Journal For Pure And Applied Sciences
Preparation of Polyester/ Micro Eggshell Fillers Composite as Natural Surface Coating
...Show More Authors

    To fabricate an inexpensive surface coating with excellent mechanical properties with good water resistance and thermal diffusion, white eggshell fibers with particle size (~1micrometer) has been added by different weight percentages (1,2,3,4,5,6,7 and 8 %) to Unsaturated Polyester.

The weight ratio (4%) of eggshell powder is a good ratio to be added to polyester to improve its mechanical properties, such as hardness, impact strength, and wear resistance. The hardness was improved by (3.75%); impact strength has the same value as polyester, flexural strength by (8.43%) and high improvement in wear resistance (74.4%), as well as to get further improvements in mechanical properties of polyester, the eggshell powder was added

... Show More
View Publication Preview PDF
Crossref (7)
Crossref
Publication Date
Wed Jan 02 2019
Journal Name
Pramana
The description of quantum dielectric function for insulators over Bethe surface
...Show More Authors

View Publication
Scopus (3)
Crossref (3)
Scopus Clarivate Crossref
Publication Date
Wed Jan 25 2023
Journal Name
International Journal Of Biomaterials
Surface Characterization of Stainless Steel 316L Coated with Various Nanoparticle Types
...Show More Authors

Background. Material tribology has widely expanded in scope and depth and is extended from the mechanical field to the biomedical field. The present study aimed to characterize the nanocoating of highly pure (99.9%) niobium (Nb), tantalum (Ta), and vanadium (V) deposited on 316L stainless steel (SS) substrates which considered the most widely used alloys in the manufacturing of SS orthodontic components. To date, the coating of SS orthodontic archwires with Nb, Ta, and V using a plasma sputtering method has never been reported. Nanodeposition was performed using a DC plasma sputtering system with three different sputtering times (1, 2, and 3 hours). Results. Structural and elemental analyses were conducted on the deposited coating

... Show More
View Publication Preview PDF
Scopus (7)
Crossref (7)
Scopus Clarivate Crossref
Publication Date
Mon Oct 04 2004
Journal Name
International Conference On Geotechnical Engineering
The Equivalent Grain Diameter for Soil Specific Surface Determination
...Show More Authors

Publication Date
Tue Sep 01 2009
Journal Name
Al-khwarizmi Engineering Journal
Propagation Mechanisms for Surface Initiated Cracking in Composite Pavements
...Show More Authors

The primary objective of this study was to identify the mechanisms for the development and propagation of longitudinal cracks that initiate at the surface of composite pavement. In this study the finite element program ANSYS version (5.4) was used and the model worked out using this program has the ability to analyze a composite pavement structure of different layer properties. Also, the aim of this study was modeling and analyzing of the composite pavement structure with the physical presence of crack induced in concrete underlying layer. The results obtained indicates that increasing the thickness of the asphalt layer tends to decrease the stress intensity factor, which may be attributed to the rapidly decrease of horizontal tensile st

... Show More
View Publication Preview PDF
Publication Date
Tue Dec 05 2023
Journal Name
Baghdad Science Journal
A Novel Water Quality Index for Iraqi Surface Water
...Show More Authors

The study aims to build a water quality index that fits the Iraqi aquatic systems and reflects the environmental reality of Iraqi water. The developed Iraqi Water Quality Index (IQWQI) includes physical and chemical components. To build the IQWQI, Delphi method was used to communicate with local and global experts in water quality indices for their opinion regarding the best and most important parameter we can use in building the index and the established weight of each parameter. From the data obtained in this study, 70% were used for building the model and 30% for evaluating the model. Multiple scenarios were applied to the model inputs to study the effects of increasing parameters. The model was built 4 by 4 until it reached 17 parame

... Show More
View Publication Preview PDF
Scopus (7)
Crossref (2)
Scopus Crossref
Publication Date
Sun Mar 30 2008
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Preparation of Zeolite Type 13X from Locally Available Raw Materials
...Show More Authors

The aim of this work was to prepare zeolite type 13X from locally available kaolin and to study the effects of using some binding materials through the process of agglomeration of this zeolite. This study was focused on using kaolin binder in different weight percents (10,15,25,35 and 45%).Physical and mechanical properties of the agglomerates such as porosity , apparent density , pore volume, crushing strength , loss on attrition , surface area and finally the adsorption capacity had been measured and evaluated .The preparation step was achieved by mixing the reactants consisting of metakaolin , source of silica as ( sodium trisilicate ) and sodium hydroxide . The conditions was temperature of 70° C and time of mixing as 8, 10,24,34,50

... Show More
View Publication Preview PDF