Preferred Language
Articles
/
joe-1836
Effect of Surface Pavement Type on Traffic Noise
...Show More Authors

This paper investigates the issue of surface-type effects on traffic noise in Baghdad. Since the raw materials for both flexible and rigid paving are available from local sources, the decision on selecting the type of paving which depends on the budget of the project and the road's importance and function. Knowing that for high traffic volumes and a high percentage of heavy vehicles, rigid pavement is more suitable compared to flexible pavement. In Baghdad, some highways consist of flexible pavement and others of combined pavement (flexible segments and rigid segments), so the study of the effect of surface type on traffic noise becomes an important matter. This study selected three highways: one with flexible pavement and two with the combined pavement. The results showed that the traffic noise generated by traffic on rigid pavement generates more noise than traffic on flexible pavement by about 2 dBA. A prediction model was generated to predict traffic noise depending on five variables (vehicle speed, traffic volume, skid number, distance between the edge of the inner lane and the sound level meter, and surface type). The measured traffic noise levels ranged from 73.23 to 82.86 dBA, which exceeded the permitted limits compared to the permissible Iraqi standards.

 

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Sun Jan 01 2023
Journal Name
Journal Of Biomechanical Science And Engineering
A COMPARATIVE STUDY OF RETN GENE 3ʹ-UNTRANSLATED REGION POLYMORPHISM RS1862513 IN IRAQI PATIENTS WITH TYPE 1 AND TYPE 2 DIABETES MELLITUS
...Show More Authors

Both type 1 diabetes and type 2 diabetes have a genetic component, with over 60 chromosomal regions related to type 1 diabetes and over 200 connected with type 2 diabetes at significant genome-wide levels. Numerous single nucleotide polymorphisms in the RETN gene and genetic variables can account for up to 70% of the variations in circulating resistin levels. The RETN polymorphism has been linked in numerous studies to obesity, insulin sensitivity, type 2 diabetes, and cerebrovascular illness. Our objective is to compare this RETN gene 3ʹ-untranslated region polymorphism in type 1 diabetes and type 2 diabetes Iraqi patients. We choose 51 type 1 diabetes and 52 type 2 diabetes patients against 50 healthy subjects (control group) to investig

... Show More
Scopus
Publication Date
Fri Sep 05 2008
Journal Name
Journal Of Kerbala University
Synthesis of New type of tetrazoles starting from D-ribose
...Show More Authors

This work includes synthesis of sugar tetrazole derivative, D-ribose reacted with acetone in the presence of sulfuric acid H2SO4 to give 2, 3-O-isopropylidene-D-ribose (1). The Aldol condensation of (1) with formaldehyde in methanolic K2CO3 solution gave 2-hydroxymethyl (2, 3-O-isopropylidene-D-ribose)(2). Which was tosylated by Tosyl chloride in pyridine to yield compound (3), SN2 reaction of (3) with sodium cyanide in DMSO afforded compound (4). The [2+ 3] cycloaddition reaction of (4) with sodium azide gave the targeted compound (5). All prepared compounds have been characterized by: TLC, Specific rotation, Microelemental analysis and [FTIR and 1 H NMR spectroscopy]

Publication Date
Mon Oct 23 2023
Journal Name
Journal Of Optics
Single mode optical fiber sensor based on surface plasmon resonance for the detection of the oil aging for the electrical transformers
...Show More Authors

This work presents a novel technique for the detection of oil aging in electrical transformers using a single mode optical fiber sensor based on surface plasmon resonance (SPR). The aging of insulating oil is a critical issue in the maintenance and performance of electrical transformers, as it can lead to reduce insulation properties, increase risk of electrical breakdown, and decrease operational lifespan. Many parameters are calculated in this study in order to examine the efficiency of this sensor like sensitivity (S), signal to noise ratio (SNR), resolution (refractive index unit) and figure of merit (FOM) and the values are for figure of merit is 11.05, the signal to noise ratio is 20.3, the sensitivity is 6.63, and the resolution is 3

... Show More
View Publication Preview PDF
Scopus (3)
Crossref (3)
Scopus Clarivate Crossref
Publication Date
Thu Dec 06 2018
Journal Name
Iraqi Journal Of Pharmaceutical Sciences ( P-issn 1683 - 3597 E-issn 2521 - 3512)
Impact of Osteocalcin Level on Vascular Calcification in Type 2 Diabetics in Relation to Fibroblast Growth Factor-23(FGF-23)
...Show More Authors

The present study aimed to assess the potential impact of serum concentration of undercarboxylated osteocalcin (the active form of osteocalcin) and fibroblast growth factor-23 on the incidence of cardiovascular diseases in type 2 diabetics with carotid artery calcification and the possible association with metabolic changes in relation to glucose and minerals homeostasis.

This study included 52 men with carotid artery calcification type 2 diabetes mellitus. These patients were categorized; as follows: group A includes 30 patients who had cardiovascular disease and group B includes 22 patients who had no cardiovascular disease. These groups were compared with 25 apparently healthy control (Group C). 

It has been shown

... Show More
View Publication Preview PDF
Scopus (10)
Crossref (2)
Scopus Crossref
Publication Date
Mon Jul 01 2013
Journal Name
Iraqi Journal Of Agricultural Sciences مجلة العلوم الزراعية العراقية
EFFECT OF HARROW TYPE AND DRILL SEEDER'S SPEEDS AND DEPTHS ON SOME MACHINERY UNIT TECHNICAL, ECONOMICAL AND ENERGY REQUIREMENT INDICATORS تأثير نوع المنعمة وسٌرع وأعماق البذار في بعض المؤشرات الفنية والأقتصادية ومتطلبات القدرة للوحدة الميكنية
...Show More Authors

Publication Date
Sat Jul 22 2023
Journal Name
Journal Of Engineering
Removal of Boron from Simulated Iraqi Surface Water by Electrocoagulation Method
...Show More Authors

The removal of boron from aqueous solution was carried out by electrocoagulation (EC) using magnesium electrodes as anode and stainless steel electrodes as cathode. Several operating parameters on the removal efficiency of boron were investigated, such as initial pH, current density, initial boron ion concentration, NaCl concentration, spacing between electrodes, electrode material, and presence of carbonate concentration. The optimum removal efficiency of 91. 5 % was achieved at a current density of 3 mA/cm² and  pH = 7 using (Mg/St. St. ) electrodes, within 45 min of operating time. The concentration of NaCl was o. 1 g/l with a 0.5cm spacing between the electrodes. First and second order rate equation were applied to study adsorp

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Tue Sep 11 2018
Journal Name
Iraqi Journal Of Physics
Measurements of radon gas concentration in surface soil in Baghdad city
...Show More Authors

In the present work, radon gas concentrations in different surface soil samples in Baghdad governorate were measured using RAD-7 detector. The results have been shown that, the Radon gas concentrations ranged between (41.67±1.78Bq/m3), to (185.67±4.22Bq/m3), a map showing the distribution of the concentration of radon in selected areas was defined to identify areas with high pollution level. The reason for the high concentration of radon is that these surface soil samples are taken from agricultural areas. It is also known that fertilizers contain uranium levels as well as areas bombed in wars in the country. It is worth noting that all radon concentrations in Baghdad governorate are below the recommended minimum of 200-300Bq/m3) (Inte

... Show More
View Publication
Crossref
Publication Date
Wed Jan 25 2023
Journal Name
International Journal Of Biomaterials
Surface Characterization of Stainless Steel 316L Coated with Various Nanoparticle Types
...Show More Authors

Background. Material tribology has widely expanded in scope and depth and is extended from the mechanical field to the biomedical field. The present study aimed to characterize the nanocoating of highly pure (99.9%) niobium (Nb), tantalum (Ta), and vanadium (V) deposited on 316L stainless steel (SS) substrates which considered the most widely used alloys in the manufacturing of SS orthodontic components. To date, the coating of SS orthodontic archwires with Nb, Ta, and V using a plasma sputtering method has never been reported. Nanodeposition was performed using a DC plasma sputtering system with three different sputtering times (1, 2, and 3 hours). Results. Structural and elemental analyses were conducted on the deposited coating

... Show More
View Publication Preview PDF
Scopus (10)
Crossref (8)
Scopus Clarivate Crossref
Publication Date
Tue Jun 15 2021
Journal Name
Iraqi Journal Of Pharmaceutical Sciences ( P-issn 1683 - 3597 E-issn 2521 - 3512)
Solubility and Dissolution Enhancement of Ebastine by Surface Solid Dispersion Technique
...Show More Authors

Ebastine (EBS) is a non-sedating antihistamine with a long duration of action. This drug has predominantly hydrophobic property causing a low solubility and low bioavailability. Surface solid dispersions (SSD) is an effective technique for improving the solubility and dissolution rate of poorly soluble drugs by using hydrophilic water insoluble carriers.

The present study aims to enhance the solubility and dissolution rate of EBS by using surface solid dispersion technique. Avicel® PH101, Avicel® PH 102, croscarmellose sodium(CCS) and sodium starch glycolate(SSG) were used as water insoluble hydrophilic carriers.

The SSD formulations of EBS were prepared by the solvent evaporation method in different drug:  carrier

... Show More
View Publication Preview PDF
Scopus (12)
Crossref (8)
Scopus Crossref
Publication Date
Fri Aug 20 2021
Journal Name
Iraqi Journal Of Laser
Pulsed Er,Cr:YSGG Laser For Surface Modification of Dental Zerconia Ceramic
...Show More Authors

Background: Surface treatment of machined dental zirconia for enhancement of the adhesion to resin cement, using Er,Cr:YSGG  Laser. Materials and Methods: Total number of 42 zirconia disc specimens (9 mm diameter, and 2 mm height) was sintered according to the manufacturer instruction. They are divided into six groups, each group of seven samples. Laser groups (Experiment parameters) were depend on laser total irradiation time, pulse duration, and power. Group (A): 20 sec., 60 µs pulse duration. Group (B): 30 sec., 60 µs pulse duration. Group (C): 40 sec., 60 µs pulse duration. Group (D): 20 sec., 700 µs pulse duration. Group (E): 30 sec., 700 µs pulse duration, with different powers used (1, 1

... Show More
View Publication Preview PDF