Power Generation from Utilizing Thermal Energy of Hazardous Waste Incinerators
...Show More Authors

A large amount of thermal energy is generated from burning hazardous chemical wastes, and the temperature of the flue gases in hazardous waste incinerators reaches up to (1200 °C). The flue gases are cooled to (40°C) and are treated before emission. This thermal energy can be utilized to produce electrical power by designing a system suitable for dangerous flue gases in the future depending on the results of much research about using a proto-type small steam power plant that uses safe fuel to study and develop the electricity generation process with water tube boiler which is manufactured experimentally with theoretical development for some of its parts which are inefficient in experimental work. The studied system generates theoretically (120 kg steam /h at 8 bars) with dry wood as fuel and preheating for the air of combustion and feed water and a diesel engine of (8 hp) four-stroke with single piston converted to steam engine coupled with the electrical generator of (3 kVA). The results are compared with practical values valid in the literature about small power plants of steam capacity (0.1-1) ton/h and operating pressure up to 10 bars. Experimentally, the generated electrical power is little and sufficient to operate a small fan and lump. The current converted steam engine is better than a conventional steam engine in auto lubrication with some operational problems. The boiler efficiency is 63.28%.

Scopus Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Wed Aug 06 2014
Journal Name
Arabian Journal Of Geosciences
Mineralogy texture and chemistry of the Ellicott meteorite using scanning electron microscope and energy disperse spectroscopy (SEM/EDS)
...Show More Authors

View Publication
Crossref (1)
Crossref
Publication Date
Fri May 01 2020
Journal Name
Journal Of Engineering
Thermal Efficiency for Passive Solar Chimney with and Without Heat Storage material
...Show More Authors

In this study, a different design of passive air Solar Chimney(SC)was tested by installing it in the south wall of insulated test room in Baghdad city. The SC was designed from vertical and inclined parts connected serially together, the vertical SC (first part) has a single pass and Thermal Energy Storage Box Collector (TESB (refined paraffin wax as Phase Change Material(PCM)-Copper Foam Matrix(CFM))), while the inclined SC was designed in single pass, double passes and double pass with TESB (semi refined paraffin wax with copper foam matrix) with selective working angle ((30o, 45o and 60o). A computational model was employed and solved by Finite Volume Method (FVM) to simulate the air i

... Show More
View Publication Preview PDF
Crossref (3)
Crossref
Publication Date
Thu Nov 21 2019
Journal Name
Al-kindy College Medical Journal
Urinary Tract Infection Risk Assessment By Non- Thermal Plasma In Iraqis Patients
...Show More Authors

Background: In the present study used device jet plasma needle with atmospheric pressure which  generates non thermal plasma jet to measure treatment potent with plasma against pathogenic bacteria  founded  in UTI  was inactivated with plasma at 10 sec,

Objective:. This work included the application of the plasma produced from the system in the field of bacterial sterilization , where sample of Gram- negative bacteria (Escherichia coli) were exposed to intervals (1-10)second . Midstream Urine samples swabs were obtained from patients with urinary tract infections.

Type of the study: Cross -sectional study.

Methods: The work were used i

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Tue May 15 2018
Pre‐low noise amplifier (LNA) filtering linearisation method for low‐power ultra‐wideband complementary metal oxide semiconductor LNA
...Show More Authors

View Publication
Crossref (3)
Clarivate Crossref
Publication Date
Wed Dec 01 2010
Journal Name
Iraqi Journal Of Physics
Study of electron energy distribution function and transport parameters for CF4 and Ar gases discharge by using the solution of Boltzmann equation-Part I
...Show More Authors

The Boltzmann transport equation is solved by using two- terms approximation for pure gases . This method of solution is used to calculate the electron energy distribution function and electric transport parameters were evaluated in the range of E/N varying from . 172152110./510.VcmENVcm
From the results we can conclude that the electron energy distribution function of CF4 gas is nearly Maxwellian at (1,2)Td, and when E/N increase the distribution function is non Maxwellian. Behavior of electrons transport parameters is nearly from the experimental results in references. The drift velocity of electron in carbon tetraflouride is large compared with other gases

View Publication Preview PDF
Publication Date
Sun Dec 12 2010
Journal Name
Journal Of Planner And Development
Utilizing the resources of the local environment in the establishment of the constituent units of the urban fabric within the framework of preservation of the urban heritage (Hassan Fathi's model experiment)
...Show More Authors

No country in the world has an ancient heritage of its own. It represents the product of the civilizations left behind by previous eras. It represents the development of urban life and its capital of the interest of its people in the field of construction and reconstruction. The urban heritage and its associated arts may seem to be a material heritage at first glance, but it is not free from the spiritual side. Therefore, the nations in different parts of the earth cherish it and care for it with all due diligence, because it mixes with its history, memories and emotions.
This research discusses the use of local environment materials in the production of urban fabric constituents. I

... Show More
View Publication Preview PDF
Publication Date
Sat Dec 01 2012
Journal Name
Iraqi Journal Of Physics
Power dissipation and time of breakdown in AC discharge of argon at a low pressure in the frequency range 5-10 kHz
...Show More Authors

The influence of 5-10 kHz audio frequency on the power dissipation in ac discharge of argon gas was studied experimentally, at pressures 50-80 mTorr and electrodes separation 10 cm (pd range 0.5-0.8 Torr.
cm). The measurements have shown that the discharge behavior in the ac circuit is equivalent to a series RC circuit. It is observed that the variation curve of discharge power P with the frequency f is approximately has a Gaussian shape. It is also observed that the curve of Pm- pd is the inverse of Paschen curve, where Pm is the maximum power in the frequency range. The time of breakdown is estimated from the curve of P- f.

View Publication Preview PDF
Publication Date
Fri Aug 01 2025
Journal Name
Bulletin Of The Chemical Society Of Ethiopia
SYNTHESIS AND CHARACTERIZATION OF NEW AZO DYE COMPLEXES AND STUDIES OF ANTIOXIDANT, BIOACTIVITY AND THERMAL ANALYSIS
...Show More Authors

A new azo dye, 5,5-[1,2-phenylenebis(2,1-biazenediyl)]bis[8-quinolino], was synthesized by reacting the diazonium salt of o-phenylenediamine with 8-hydroxyquinoline. The ligand was subsequently used to prepare a series of metal complexes with V(IV), Fe(III), Cr(III), Mn(II), Mo(VI), and Ru(III). The ligand was characterized using 1H and 3C-NMR spectroscopy, while the metal complexes were analyzed using UV-Vis, FT-IR, and mass spectrometry, along with thermal analysis (TGA, DSC), (C.H.N.), conductivity measurements, magnetic susceptibility, and metal and chlorine content analysis, the results indicated that the ligand exhibits tetracoordination. The complexes predominantly formed octahedral geometries, except for the vanadium complex, which

... Show More
Publication Date
Fri Oct 01 2010
Journal Name
Iraqi Journal Of Physics
The effect of TiO2 addition on the thermal conductivity of Polymethylmetha acrylate, Polycarbonate and Polystyrene Polymers
...Show More Authors

Thermal conductivity measurement was done for specimens of Polystyrene/ titanium dioxide, Polycarbonate/ titanium dioxide and Polymethylmetha acrylate/ titanium dioxide composites for weight ratio of 1.9/ 0.1 and 1.8/ 0.2 wt% for different thickness of the samples. The experimental results show that the thermal conductivity is increased with the increasing of thickness of layers and with the weight ratio of TiO2

View Publication Preview PDF
Publication Date
Fri May 01 2015
Journal Name
Journal Of Engineering
Experimental Study of the Thermal Performance of Flat Plate Solar Collectors Array by Different Connection Configurations
...Show More Authors

The current research illustrates experimentally the effect of series and parallel connection (Z-I Configurations) of flat plate water solar collectors array on the thermal performance of closed loop solar heating system. The study includes the effect of changing the water flow rate on the thermal efficiency. The results show that, the collector's efficiency in series connection is higher than the parallel connection within flow rate level less than (100) ℓ/hr. Moreover, the collector efficiency in parallel connection of (I-Configurations) is more than the (Z- Configurations) with increasing the water flow rate .The maximum daily efficiency for parallel (I-Configurations) and (Z- Configurations) are (55%) and (51%) at w

... Show More
View Publication Preview PDF