Preferred Language
Articles
/
joe-1686
Producing Load Bearing Block Using LECA as Partial Replacement of Coarse Aggregate
...Show More Authors

The ability to produce load-bearing masonry units adopting ACI 211.1 mix design using (1:3.2:2.5) as (cement: fine aggregate: coarse aggregate) with slump range (25-50mm) which can conform (dimension, absorption, and compressive strength) within IQS 1077/1987 requirements type A was our main goal of the study. The ability to use low cement content (300 kg/m3) to handle our market price products since the most consumption in wall construction for low-cost buildings was encouraging. The use of (10 and 20%) of LECA as partial volume replacement of coarse aggregate to reduce the huge weight of masonry blocks can also be recommended. The types of production of the load-bearing masonry units were A and B for (10 and 20%), respectively. Finally, the use of the spray curing method was the more suitable simulation of reality and easier for factory producers, taking into consideration that the increasing curing time from 14 days (recommended in IQS 1077/1987) to 28 days may be led to conversation masonry type from B to A as in R20%-300.  

 

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Wed Dec 02 2020
Journal Name
Iraqi Journal Of Agricultural Sciences
EVALUTION OF ANTIMICROBIAL ACTIVITY OF PARTIAL PURIFIED BACTERIOCIN FROM LOCAL ISOLATE OF BACILLUS LICHENIFORIMS HJ2020 MT192715.1
...Show More Authors

This study was aimed to produce bacteriocin from Bacillus. licheniformis isolated from local soil of corn and sunflower fields and using as antimicrobial agent . Fourteen of local isolates of Bacillus sp. were obtained and ability of these isolates for growth on Brain heart infusion agar (BHI) at 550C were tested. Isolate C4 was revealed high growth density in comparison with other isolates. Isolate C4 was identified as Bacillus licheniformis according to morphological, cultural and biochemical tests, Moreover genetic analysis for 16S rRNA gene and given accession number MT192715.1 in GenBank of NCBI . Production of bacteriocin from this isolate was carried out in Luria Broth (LB) and partially purified by precipitation with 30-70 % saturat

... Show More
Publication Date
Sun Sep 02 2012
Journal Name
Baghdad Science Journal
Effect of Replacing Partial of Wheat Flour by Lentil Powder on Quality Properties of Laboratory Bread
...Show More Authors

This investigation was carried out to examine the effect of replacing partial of flour by dried Lentils (Lens culinaris) to white flour in different percentages on the chemical, sensory and storage properties of the Laboratory bread. The results revealed that replacing 0% than wheat flour by lentil powder (1) control was high significan than the replacing 25 and 35% than wheat flour by lentil powder ( 4 and 5) in flavor and chewiness . The results of sensory evaluation showed that replacing 4 were high significan different than that of replacing 1 in external layer colour. Other replacing percentages, however, did not show significant differences of in comparison with control . In regards with chemical analysis of Iron and copper, i

... Show More
View Publication Preview PDF
Crossref
Publication Date
Thu Dec 01 2022
Journal Name
Journal Of Engineering
The Optimum Reinforcement Layer Number for Soil under the Ring Footing Subjected to Inclined Load
...Show More Authors

The primary components of successful engineering projects are time, cost, and quality. The use of the ring footing ensures the presence of these elements. This investigation aims to find the optimum number of geogrid reinforcement layers under ring footing subjected to inclined loading. For this purpose, experimental models were used. The parameters were studied to find the optimum geogrid layers number, including the optimum geogrid layers spacing and the optimum geogrid layers number. The optimum geogrid layers spacing value is 0.5B. And as the load inclination angle increased, the tilting and the tilting improvement percent for the load inclination angles (5°,10°,15°) are (40%,28%, and 5%) respectively. The reduction percent of the

... Show More
View Publication Preview PDF
Crossref (4)
Crossref
Publication Date
Sat Feb 04 2023
Journal Name
Sport Tk-revista Euroamericana De Ciencias Del Deporte
Functional thinking style and its contribution to learn the accuracy of block and smash serve in volleyball among university students
...Show More Authors

This study aimed to analyze functional thinking style and its contribution to learn the accuracy of block and smash serve in volleyball among university students. The sample was composed of 120 students of the College of Physical Education and Sports Sciences of the University of Baghdad (academic year 2021/2022). The statistical analyses were carried out with the statistical software SPSS and correlation analyses were conducted. It was found that functional thinking style significantly contributed to learn the accuracy of block and smash serve in volleyball among university students. Therefore, it is necessary to intensify efforts to increase the level of functional thinking among university students, by adopting acad

... Show More
View Publication
Scopus Crossref
Publication Date
Sat Mar 01 2014
Journal Name
International Journal For Sciences And Technology
Preparation of Carboxy Methylated mPEG-Block-(4-Dodecyl Anilide) Copolymers and Their Visco Metric and Surface Tension Properties in THF
...Show More Authors

Preparation of Carboxy Methylated mPEG-Block-(4-Dodecyl Anilide) Copolymers and Their Visco Metric and Surface Tension Properties in THF

Publication Date
Sun May 01 2016
Journal Name
Istanbul Bridge Conference.- Turkey
Strengthening and Load Testing for Short Span Steel Bridge for Abnormal Loads
...Show More Authors

The steel jetty selected for strengthening is in Baghdad city, over Tigris River, consists of 55 short spans, each of approximately 4 meters and one naviga-tional opening of 12 m. The bridge is 224 meters length and 8 meters in width. The strengthening system was designed to remove overstresses that occurred when the bridge was subjected to abnormal loads of 380 tons. A strengthening system which installed in spring 2008 was used where the main concept is to depend on added side supporting elements which impose reversal forces on the bridge to counteract most of the loads expected from the abnormal heavy loads. The bridge was load tested before and after the strengthening system was activated. The load test results indicate that the strengt

... Show More
Publication Date
Sat Dec 01 2018
Journal Name
Al-khwarizmi Engineering Journal
Crack Growth Behavior through Wall Pipes under Impact Load and Hygrothremal Environment
...Show More Authors

This research concerns study the crack growth in the wall of pipes made of low carbon steel under the impact load and using the effect of hygrothermal (rate of moisture 50% and 50℃ temperature). The environmental conditions were controlled using high accuracy digital control with sensors. The pipe have a crack already. The test was performed and on two type of specimens, one have length of 100cm and other have length 50cm. The results were, when the humidity was applied to the pipe, the crack would enhance to growth (i.e. the number of cycles needed to growth the crack will reduce). In addition, when the temperature was increase the number of cycles needed to growth the crack are reduced because the effect of heat on the mechanical pro

... Show More
View Publication Preview PDF
Crossref
Publication Date
Mon Jul 17 2023
Journal Name
Journal Of The Iraqi University
Analysis of the Content of the Physics Textbook of the 3rd Intermediate Grade According to the Criteria for Designing and Producing in Fographics
...Show More Authors

In this study, the researcher aims to analyze the content of the physics textbook for the 3rd intermediate grade according to the criteria for designing and producing infographics, and the research community consists of the content of the physics textbook for the 3rd intermediate grade intermediate grade for the academic year 2021-2022. The researcher adopted the analysis instruments with a number of the criteria for designing and producing infographics. The results revealed randomness in the percentage of the criteria included in the content of the physics textbook for the 3rd intermediate grade, and they are not compatible with the proposed criteria by the experts also.

Publication Date
Thu Jan 25 2018
Journal Name
International Journal Of Current Engineering And Technology
Model-Based Design of Piezoelectric Patches used to Repair Damaged Beams under Static Load
...Show More Authors

Static loads exposing to mechanical components can cause cracks, which are lead to form stress concentration regions causing the failure of structure. Generally, from 80% to 90% of structure failure is due to initiation of the cracks. Therefore, it is necessary to repair the crack and reduce its effect on the structure where the effect of the crack is modelled as an additional flexibility to the structure. In the last few years, piezoelectric materials have been considered as one of the most favourable repairing techniques. The piezoelectric material converts the applied voltage on it to a bending moment to counter the bending moment caused by the external load on the beam at the crack location. In this study, the design of the piez

... Show More
View Publication Preview PDF
Crossref
Publication Date
Wed Jul 01 2020
Journal Name
Iop Conf. Series: Materials Science And Engineering
Structural Performance of Slender RC Columns with Cross and Square-Shaped under Compression Load
...Show More Authors
Abstract<p>The idea of using slender Reinforced Concrete (RC) columns with cross-shaped (+-shaped) instead of columns with square-shaped was discussed in this paper. The use of +-shaped columns provides many architectural and structural advantages, such as avoiding prominent columns edges and improved the structural response of member. Therefore, this study explores the structural response of slender +-shaped columns experimentally and numerically by nonlinear finite element analysis using Abaqus simulation tools. The results showed an excellent convergence in strength between numerical and test results with an average standard deviation of 0.05 and 0.07. Besides that, the use of +-shaped column</p> ... Show More
Scopus (2)
Crossref (1)
Scopus Crossref