This study deals with the serviceability of reinforced concrete solid and perforated rafters with openings of different shapes and sizes based on an experimental study that includes 12 post-fire non-prismatic reinforced concrete beams (solid and perforated). Three groups were formed based on heating temperature (room temperature, 400 °C, and 700 °C), each group consisting of four rafters (solid, rafters with 6 and 8 trapezoidal openings, and rafter with eight circular openings) under static loading. A developed unified calculation technique for deflection and crack widths under static loading at the service stage has been provided, which comprises non-prismatic beams with or without opening exposed to flexure concentrated force. Two approaches were used to compute the deflection: The first attempt was conducted by using the moment of inertia for solid non-prismatic beam and reduced for those with openings by the ratio of residual rafter self-weight. The second was performed by using the moment of inertia of transformed cracked sections depending on the segmental rafter method. The crack width was determined using the ACI code's equation. The analytical and experimental results were evaluated and found to be in good agreement.
Introduction: COVID-19 vaccine have been indicated to successfully decrease the hazard for symptomatic severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) infection furthermore associated hospitalisations. Objective: To study the immune response among different types of SARS-CoV-2 vaccines. Methods: This study includes 100 vaccinated individuals (43 Sinopharm, 30 AstraZeneca and 27 Pfizer) with one or two doses from different health centres in Baghdad. During the period from April 2021 to the end of May 2021, SARS-CoV-2 IgG and SARS-CoV-2 IgM levels were detected using AFIAS-6 device depending on FIA (Fluorescence Immunoassay) technique. Results: 93% of the cases were positive for IgG levels, and negative in 7% case
... Show MoreStatistical studies are reported in this article for an active galactic nuclei sample of different type of active galaxies Seyferts 1, Seyferts 2, and Quasars. These sources have been selected from a Catalogue for bright X-ray galaxies. The name of this index is ROSAT Bright Source Catalogue (RBSC) and the NRAO VLA Sky Survey (NVSS). In this research, multi-wavelength observational bands Radio at 1.4 GHz, Optical at 4400 A0, and X-ray at energy 0.1-2.4 KeV have been adopted in this study. The behavior of flux density ratios has been studied , with respect to the absolute magnitude . Furthermore, the Seyfert1 and Seyfert 2 objects are combined in one group and the QSOs are collectest in another group. Also, it has been found that t
... Show MoreTwelve samples of cigarettes have been collected from local markets of different types and origins by using (HPGe) detector, and measurement of the specific activity for series U238 and series Th232 in addition to K40 in order to estimate the health risk of cigarettes their by smokers, the results shown that highest specific activity value were be (12. 8±6. 3 Bq/kg, 8. 41±5. 8 Bq/kg, 125. 16±58. 3 Bq/kg), respectively, in the sample (MAC) MacBeth type cigarettes in Brazilian origin, this paper reports data such as (specific activity of K40, series U238, series Th232
Abstract Background: This in-vitro study was to evaluated bitewing radiograph and tactile examination for detection secondary caries adjacent to amalgam restorations. Material and method: Sixty primary extracted molars with class I and class II amalgam restorations were selected from children, and examined by bitewing radiographs were taken by using film holders and interpreted on a backlit screen without magnification. Then, we used tactile examination with blunt probe. Result: The result of this study showed that the best cut-off points for the sample were found by a Receiver Operator Characteristic (ROC) analysis, and the area under the ROC curve and the sensitivity, specificity and accuracy of the techniques were calculated for enamel (
... Show MoreIn this paper, two parameters for the Exponential distribution were estimated using the
Bayesian estimation method under three different loss functions: the Squared error loss function,
the Precautionary loss function, and the Entropy loss function. The Exponential distribution prior
and Gamma distribution have been assumed as the priors of the scale γ and location δ parameters
respectively. In Bayesian estimation, Maximum likelihood estimators have been used as the initial
estimators, and the Tierney-Kadane approximation has been used effectively. Based on the MonteCarlo
simulation method, those estimators were compared depending on the mean squared errors (MSEs).The results showed that the Bayesian esti