This study aims at identifying the notion of Post-Occupancy Evaluation (POE) pertinent to the performance of three general hospitals constructed inside the Sulaimani City, tracing the relationship between the quality of the indoor environments and medical staff (doctors and nurses) satisfaction level. Using some indoor environment elements in the right way will positively influence the mood, stress level of the medical staff, and patient recovery as a result. The POE toolkits (AEDET and ASPECT) have been implemented on targeted wards at the selected hospitals. AEDET and ASPECT questionnaires were distributed among 152 medical staff to obtain their perspectives. In total, 112 valid questionnaires were received. The medical staff at tested hospitals were generally satisfied with the quality of newly built hospitals' indoor environment. The results have shown that exploring medical staff experiences can expose factors that affect their satisfaction levels. Also, the findings reveal that the building's physical quality can be vastly related to the fulfillment of the medical staff's satisfaction. Moreover, the findings underline the role of the quality of the indoor environment in increasing medical staff's satisfaction levels, informing design decisions. Additionally, the persuasive associative outcomes have proven that POE (AEDET and ASPECT) will be pertinent as a tool to the building's physical quality.
Firstly, in this study, a brief updated description and applications of different solar collectors used in renewable energy systems for supplying electric and thermal energy was presented. Secondly, an attempt was made to utilize tilting orientation of solar collector for maximizing collector energy with time in respect to horizontal orientation. For energy calculation, global solar radiation was used since they are directly related. For that purpose, field measurements of half-hourly radiation on two flat panels of tilting and horizontal orientations were carried out throughout 8-month period under local climate of Baghdad. Then, energy gain and radiation level averages were calculated based on the field radiation
... Show MoreBackground: Few updated retrospective histopathological-based studies in Iraq evaluate a comprehensive spectrum of oro-maxillofacial lesions. Also, there was a need for a systematic way of categorizing the diseases and reporting results in codes according to the WHO classification that helps occupational health professionals in the clinical-epidemiological approach.
Objectives: to establish an electronic archiving database according to the ICD-10 that encompasses oro-maxillofacial lesions in Sulaimani city for the last 12 years, then to study the prevalence trend and correlation with clinicopathological parameters.
Subjects and Methods: A descri
... Show MoreIntersectionality is a concept that focuses on social inequality towards black people and provides an analytical instruments for creating social justice issues in such a way in order to depict how social marginalization, or privilege occurs differently in various social positions. It does this by focusing on the interaction of multiple systems of oppression. Intersectionality is used to examines how the social factors; race, gender, and class can affect the people’s life especially the immigrants, black people, and refuges. This article will depicts how blacks in Canada are segregated and distinguished from white race. David Chariandy’s I’ve Been Meaning To Tell You: A Letter to My Daughter 2018 is analyzed through Kimberle Crenshaw
... Show MoreIn this study, the response of ten composite post-tensioned concrete beams topped by a reinforced concrete deck with adequate reinforcing shear connectors is investigated. Depending on the concrete compressive strength of the deck slab (20, 30, and 40 MPa), beams are grouped into three categories. Seven of these beams are exposed to a fire attack of 700 and 800 °C temperature simultaneously with or without the presence of a uniformly distributed sustained static loading. After cooling back to ambient temperature, these composite beams are loaded up to failure, using a force control module, by monotonic static loading in a four-point-bending setup with two symmetrical concentrated loads applied in
In this study, the response of ten composite post-tensioned concrete beams topped by a reinforced concrete deck with adequate reinforcing shear connectors is investigated. Depending on the concrete compressive strength of the deck slab (20, 30, and 40 MPa), beams are grouped into three categories. Seven of these beams are exposed to a fire attack of 700 and 800 °C temperature simultaneously with or without the presence of a uniformly distributed sustained static loading. After cooling back to ambient temperature, these composite beams are loaded up to failure, using a force control module, by monotonic static loading in a four-point-bending setup with two symmetrical concentrated loads applied in
This paper presents a study to investigate the behavior of post-tensioned segmental concrete beams that exposed to high-temperature. The experimental program included fabricating and testing twelve simply supported beams that divided into three groups depending on the number of precasting concrete segments. All specimens were prepared with an identical length of 3150 mm and differed in the number of the incorporated segments of the beam (9, 7, or 5 segments). To simulate the genuine fire disasters, nine out of twelve beams were exposed to a high-temperature flame for one hour. Based on the standard fire curve (ASTM – E119), the temperatures of 300◦C (572◦F), 500◦C (932◦F), and 700◦C (1292◦F) were adopted. Consequently,
... Show MoreThis paper presents a study to investigate the behavior of post-tensioned segmental concrete beams that exposed to high-temperature. The experimental program included fabricating and testing twelve simply supported beams that divided into three groups depending on the number of precasting concrete segments. All specimens were prepared with an identical length of 3150 mm and differed in the number of the incorporated segments of the beam (9, 7, or 5 segments). To simulate the genuine fire disasters, nine out of twelve beams were exposed to a high-temperature flame for one hour. Based on the standard fire curve (ASTM – E119), the temperatures of 300◦C (572◦F), 500◦C (932◦F), and 700◦C (1292◦F) were adopted. Consequently,
... Show MoreThis paper presents a robust algorithm for the assessment of risk priority for medical equipment based on the calculation of static and dynamic risk factors and Kohnen Self Organization Maps (SOM). Four risk parameters have been calculated for 345 medical devices in two general hospitals in Baghdad. Static risk factor components (equipment function and physical risk) and dynamics risk components (maintenance requirements and risk points) have been calculated. These risk components are used as an input to the unsupervised Kohonen self organization maps. The accuracy of the network was found to be equal to 98% for the proposed system. We conclude that the proposed model gives fast and accurate assessment for risk priority and it works as p
... Show MoreThe present research aims to identify and define the basic dimensions of the information management strategy and the administrative creativity in the Faculty of Management and Economics / the University of Kirkuk, as well as the role played by the dimensions of the information technology management strategy in achieving the administrative innovation in the college and the research problem was formulated in several questions. The research problem was formulated in several questions centered on the correlation between the research variables, and the research was based on a major hypothesis and five sub-hypotheses emerged from which it was subjected to several tests to ensure its validity. The researcher used the descriptive-analyti
... Show More