Preferred Language
Articles
/
joe-124
Energy and Exergy Analyses of Heat Pump Cycle with Refrigerant Injection Technology
...Show More Authors

The effect of refrigerant injection techniques on the performance of heat pump system based on exergy analysis was studied theoretically. Three refrigerant injection techniques were used; the first was achieved by injected vapour in volume ratios from 1 to 7% in the accumulator. The second was injection liquid refrigerant in the discharge line with the aid of Liquid Pressure Amplification (LPA) pump, with volume ratios from 1 to 10%. The third was a hybrid injection with volume ratios of injected vapour and liquid varied from 1 to 3% and 1 to 10%; respectively. The following improvements in cycle performance were observed. For vapour injection technique, the best ratio of injection was 5%, the exergy destruction reduced by 21% and exergy efficiency enhanced by 14.6%. For liquid injection technique the best ratio of injection was 6%, the reduction in exergy destruction was 34% while the exergy efficiency increased by about 21.4%. The hybrid injection technique increased the exergy efficiency by 23% when the volume ratio of vapour and liquid injections are 3% each. The effect of condensing pressure on the cycle performance was studied also. The optimum exergy efficiency of the cycle was 54.55% achieved when the condensing pressure was 15 bars.

                                              

 

View Publication Preview PDF
Quick Preview PDF
Publication Date
Mon May 01 2023
Journal Name
Journal Of Engineering
Experimental Investigation of Heat Transfer Enhancement in a Double Pipe Heat Exchanger Using Compound Technique of Transverse Vibration and Inclination Angle
...Show More Authors

Numerous tests are recently conducted to assess vibration's role in accelerating the heat transfer rate in various heat exchangers. In this work, the enhancement of heat transfer by the effect of transfer vibration and inclination angles on the surface of a double pipe heat exchanger experimentally has been investigated. A data acquisition system is applied to record the data of temperatures, flow rates, and frequencies over the tests. A compound technique was adopted, including the application of a set of inclination angles of (0°, 10°, 20°, and 30°) under the effect of frequency of vibration ranging from sub-resonance to over-resonance frequencies. The results showed that the overall heat transfer coefficient enhan

... Show More
View Publication Preview PDF
Crossref (5)
Crossref
Publication Date
Fri Dec 20 2019
Journal Name
Iet Circuits, Devices & Systems
Multi‐bit error control coding with limited correction for high‐performance and energy‐efficient network on chip
...Show More Authors

In the presence of deep submicron noise, providing reliable and energy‐efficient network on‐chip operation is becoming a challenging objective. In this study, the authors propose a hybrid automatic repeat request (HARQ)‐based coding scheme that simultaneously reduces the crosstalk induced bus delay and provides multi‐bit error protection while achieving high‐energy savings. This is achieved by calculating two‐dimensional parities and duplicating all the bits, which provide single error correction and six errors detection. The error correction reduces the performance degradation caused by retransmissions, which when combined with voltage swing reduction, due to its high error detection, high‐energy savings are achieved. The res

... Show More
View Publication
Scopus (2)
Crossref (1)
Scopus Clarivate Crossref
Publication Date
Tue Nov 03 2020
Journal Name
Modern Sport
Exercises based on the phosphogenic energy system to develop the ability to perform with precision and accuracy
...Show More Authors

Each sport has its own energy requirements that differ from the energy requirements of other sports, and a different method is used in each of them, so the trainer must first rely on the principle of privacy in training first, that is, privacy according to the working energy system, that is, he defines the controlling energy system In that event, and how the muscles use the available energy to perform according to the energy production systems. As we find the serving skill is the first volleyball skill with which the team starts the match in order to be able to gain points directly, through knowledge it turns out that there is a weakness in the skill performance, especially the skill of serving and being The key to victory for volle

... Show More
Crossref (1)
Crossref
Publication Date
Sun Jun 01 2008
Journal Name
Baghdad Science Journal
The role of annealing temperature on the optical energy gap and Urbach energy of Se:2%Sb thin films
...Show More Authors

The optical energy gap(Eopt) and the width of the tails of localized states in the band gap (?E) for Se:2%Sb thin films prepared by thermal co-evaporation method as a function of annealing temperature are studied in the photon energy range ( 1 to 5.4)eV.Se2%Sb film was found to be indirect transition with energy gap of (1.973,2.077, 2.096, 2.17) eV at annealing temperature (295,370,445,520)K respectively. The Eopt and ?E of Se:2%Sb films as a function of annealing temperature showed an increase in Eopt and a decrease in ?E with increasing the annealing temperature. This behavior may be related to structural defects and dangling bonds.

View Publication Preview PDF
Crossref
Publication Date
Wed Mar 30 2022
Journal Name
World Economics & Finance Bulletin (wefb)
ANALYSIS AND MEASUREMENT THE CONCURRENT FINANCIAL AND ECONOMIC CYCLE IN THE IRAQI ECONOMY FOR THE PERIOD 1990-2018
...Show More Authors

The research aims to verify the presence of correlation between the financial cycle and the economic cycle in the Iraqi economy. During the research period, the Iraqi economy witnessed a crisis cycle due to the permanent deviations in the state budget and the occurrence of sustainable deficits during the period of the economic blockade with the coincidence of an inflationary economic cycle due to the cheap money policy and the occurrence of Negative supply shocks due to the blockade and the madly high general level of prices, in addition to the weak financial planning of the state budget during the post-economic blockade and the entry of the economy into a stagnant economic cycle due to security and political instability, low levels of priv

... Show More
View Publication Preview PDF
Publication Date
Mon Jul 31 2023
Journal Name
Iraqi Geological Journal
Estimation of the Fracturing Parameters and Reservoir Permeability Using Diagnostic Fracturing Injection Test
...Show More Authors

The term "tight reservoir" is commonly used to refer to reservoirs with low permeability. Tight oil reservoirs have caused worry owing to its considerable influence upon oil output throughout the petroleum sector. As a result of its low permeability, producing from tight reservoirs presents numerous challenges. Because of their low permeability, producing from tight reservoirs is faced with a variety of difficulties. The research aim is to performing hydraulic fracturing treatment in single vertical well in order to study the possibility of fracking in the Saady reservoir. Iraq's Halfaya oil field's Saady B reservoir is the most important tight reservoir. The diagnostic fracture injection test is determined for HF55using GOHFER soft

... Show More
View Publication
Scopus Crossref
Publication Date
Thu Jun 30 2016
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Entransy Dissipation of Shell and Double Concentric Tubes Heat Exchanger
...Show More Authors

The concept of entransy dissipation was determined for new type of heat exchanger (shell and double concentric tubes heat exchanger). Three parameters, hot oil flow rate, temperature of inlet hot oil and pressure drop of system were investigated with this concept (entransy dissipation). The results showed that the value of entransy dissipation of oil and of system which represents the summation of entransy dissipation of both oil and water increased with increasing the flow rate of hot oil and these values were larger when cold water flow rate was doubled. Also they were increased with increasing the hot oil inlet temperature at a certain flow rate of hot oil. Furthermore, the pressure drops for hot oil in both shell side and inner tubes

... Show More
View Publication Preview PDF
Publication Date
Wed Jun 01 2016
Journal Name
Journal Of Engineering
Entropy Generation of Shell and Double Concentric Tubes Heat Exchanger
...Show More Authors

Entropy generation was studied for new type of heat exchanger (shell and double concentric tubes heat exchanger). Parameters of hot oil flow rate, temperature of inlet hot oil and pressure drop were investigated with the concept of entropy generation. The results showed that the value of entropy generation increased with increasing the flow rate of hot oil and when cold water flow rate was doubled from 20 to 40 l/min, these values were larger. On the other hand, entropy generation increased with increasing the hot oil inlet temperature at a certain flow rate of hot oil. Furthermore, at a certain hot oil inlet temperature, the entropy generation increased with the pressure drop at different hot oil inlet flow rates. Final

... Show More
View Publication Preview PDF
Publication Date
Fri Mar 06 2020
Journal Name
Iop Conference Series: Materials Science And Engineering
Building HEC-RAS model to detect the areas of Water Cycle Interruption in river stream and their sections
...Show More Authors

The purpose of this paper is to build a simulation model by using HEC-RAS software to simulate the reality of water movement in the main river of Basra City (South of Iraq) which is known as Siraji-Khoura River. The main objective of the simulation is to detect areas where the water cycle is interrupted in some stations of the river stream, as this river has become an outlet for the disposal of sewage, leading to pollution and causing weakness in some sections of the river & obstructing the water cycle that takes place between this river and Shatt al – Arab river. A field survey data of the river and its banks were adopted to derive the grades, longitudinal and cross sections of the river, these data included three-dimensional coordinates

... Show More
View Publication
Scopus (6)
Crossref (1)
Scopus Clarivate Crossref
Publication Date
Tue Jul 22 2025
Journal Name
Kerbala Journal Of Pharmaceutical Sciences
Determination of Methionine Via Chemiluminescence-Continuous Flow Injection Analysis
...Show More Authors

The research work represent a fast and simple method for the determination of methionine using chemiluminescence for the methionine-sodium hydroxide-luminol for the generation of a chemiluminesecent derivative of luminal. The emission was measured by continuous flow analysis made sample size of 83µL was used.Response versus concentration extended from 0.2-20 mM.L-1 with a percentage linearity of 96.17% or with 99.17% percentage of linearity for the range 0.6-20 mM.L-1. Reaching to a L.O.D. at (S/N=3) for 5 µM.L-1 from the gradual dilution for the minimum concentration in the calibration graph with a repeatability of less than 0.5% (n=10). A comparison was made between the new developed method with the classical method for the spectrophoto

... Show More
View Publication