Preferred Language
Articles
/
joe-1181
National Grid Connected 3-Phase Inverter based on Photovoltaic Solar System
...Show More Authors

In this paper, a national grid-connected photovoltaic (PV) system is proposed. It extracts the maximum power point (MPP) using three-incremental-steps perturb and observe (TISP&O) maximum power point tracking (MPPT) method. It improves the classic P&O by using three incremental duty ratio (ΔD) instead of a single one in the conventional P and O MPPT method. Therefore, the system's performance is improved to a higher speed and less power fluctuation around the MPP. The Boost converter controls the MPPT and then is connected to a three-phase voltage source inverter (VSI). This type of inverter needs a high and constant input voltage. A second-order low pass (LC) filter is connected to the output of VSI to reduce the total harmonic distortion (THD) of the output current. The LC filter is then connected to a step-up transformer to push up the low VSI output voltage to the high grid voltage level. The control strategy is based on the rotating reference frame (dq reference frame) and the grid phase shift angle extracted using a phase-locked loop (PLL) technique. The designed PV system supplies only active power with zero reactive power to the utility grid. The system is simulated using MATLAB / Simulink software.

 

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Sun Oct 01 2023
Journal Name
Baghdad Science Journal
Best Proximity Point Theorem for α ̃–ψ ̃-Contractive Type Mapping in Fuzzy Normed Space
...Show More Authors

The best proximity point is a generalization of a fixed point that is beneficial when the contraction map is not a self-map. On other hand, best approximation theorems offer an approximate solution to the fixed point equation . It is used to solve the problem in order to come up with a good approximation. This paper's main purpose is to introduce new types of proximal contraction for nonself mappings in fuzzy normed space and then proved the best proximity point theorem for these mappings. At first, the definition of fuzzy normed space is given. Then the notions of the best proximity point and - proximal admissible in the context of fuzzy normed space are presented. The notion of α ̃–ψ ̃- proximal contractive mapping is introduced.

... Show More
View Publication Preview PDF
Scopus (1)
Scopus Crossref
Publication Date
Wed Jun 26 2019
Journal Name
Iraqi Journal Of Science
Fixed Point Theorems of Fuzzy T*-Cone Metric Space and Their Integral Type Application
...Show More Authors

The objective of this work is to study the concept of a fuzzy -cone metric space And some related definitions in space. Also, we discuss some new results of fixed point theorems. Finally, we apply the theory of fixed point achieved in the research on an integral type.

View Publication Preview PDF
Scopus Crossref
Publication Date
Wed Mar 08 2017
Journal Name
Ibn Al-haitham Journal For Pure And Applied Sciences
Mesomorphic and Dielectric Properties of Heterocyclic Liquid Crystals with Different Terminal Groups
...Show More Authors

    A new hetrocyclic liquid crystal compounds containing 1,3,4-oxadiazole with different substituted in para position (Bromo, Chloro, Nitro and Methyl) were synthesized and characterized by melting points, FTIR Spectroscopy and 1HNMR spectroscopy for [Cl-SR6] and [NO2-SR6] compounds. The liquid crystalline properties of the synthesized compounds were studied by using hot-stage polarizing optical microscopy (POM), so they determined the transition enthalpies and entropies by using differential scanning calorimetery (DSC). All of the compounds show mesomorphic properties. The compounds [Br-SR6], [Cl-SR6] and [NO2SR6] exhibit an enantiotropic dimorphism smectic (Sm) phase, while the compounds [MeSR6] showed nematic (N) phase thro

... Show More
View Publication Preview PDF
Publication Date
Sat Dec 30 2023
Journal Name
Iraqi Journal Of Science
Energy Consumption Prediction of Smart Buildings by Using Machine Learning Techniques
...Show More Authors

     This paper presents an IoT smart building platform with fog and cloud computing capable of performing near real-time predictive analytics in fog nodes. The researchers explained thoroughly the internet of things in smart buildings, the big data analytics, and the fog and cloud computing technologies. They then presented the smart platform, its requirements, and its components. The datasets on which the analytics will be run will be displayed. The linear regression and the support vector regression data mining techniques are presented. Those two machine learning models are implemented with the appropriate techniques, starting by cleaning and preparing the data visualization and uncovering hidden information about the behavior of

... Show More
View Publication Preview PDF
Scopus Crossref
Publication Date
Thu Apr 01 2021
Journal Name
Neuroquantology
Finding Most Stable Isobar for Nuclides with Mass Number (165- 175) against Beta Decay
...Show More Authors

In the beta decay process, a neutron converts into a proton, or vice versa, so the atom in this process changes to a more stable isobar. Bethe-Weizsäcker used a quasi-experimental formula in the present study to find the most stable isobar for isobaric groups of mass nuclides (A=165-175). In a group of isobars, there are two methods of calculating the most stable isobar. The most stable isobar represents the lowest parabola value by calculating the binding energy value (B.E) for each nuclide in this family, and then drawing these binding energy values as a function of the atomic number (Z) in order to obtain the mass parabolas, the second method is by calculating the atomic number value of the most stable isobar (ZA). The results show

... Show More
Publication Date
Wed Mar 08 2017
Journal Name
Ibn Al-haitham Journal For Pure And Applied Sciences
Mesomorphic and Dielectric Properties of Heterocyclic Liquid Crystals with Different Terminal Groups
...Show More Authors

  A new hetrocyclic liquid crystal compounds containing 1,3,4-oxadiazole with different substituted in para position (Bromo, Chloro, Nitro and Methyl) were synthesized and characterized by melting points, FTIR Spectroscopy and 1HNMR spectroscopy for [Cl-SR6] and [NO2-SR6] compounds. The liquid crystalline properties of the synthesized compounds were studied by using hot-stage polarizing optical microscopy (POM), so they determined the transition enthalpies and entropies by using differential scanning calorimetery (DSC). All of the compounds show mesomorphic properties. The compounds [Br-SR6], [Cl-SR6] and [NO2SR6] exhibit an enantiotropic dimorphism smectic (Sm) phase, while the compounds [MeSR6] showed nematic (N) phase throw cooli

... Show More
View Publication Preview PDF
Publication Date
Sun May 07 2017
Journal Name
Ibn Al-haitham Journal For Pure And Applied Sciences
Theoretical Calculation of Reorientation Energy in Metal /Semiconductor Interface
...Show More Authors

A theoretical calculation of the reorientation energy for non adiabatic electron transfer at
interface between metal and semiconductor system was carried out. The continuum outer
sphere theory of electron transfer reaction has been extensively used for electron transfer
between metal/semiconductor interface .It is found that in these calculations the reorientation
energy is proportional to the optical and statistical dielectric constant of semiconductor ,
properties of metal ,and the distance between metal and semiconductor .Results of
reorientation energy show that ZnO semiconductor with metal Au possess a good matching as
compared with ZnS and ZnSe . Theoretical calculation showed a good agreement with
ex

... Show More
View Publication Preview PDF
Publication Date
Sun Jun 05 2016
Journal Name
Baghdad Science Journal
Adiponectin , ?-Cell Dysfunction in Iraqi Women with Gestational Diabetes
...Show More Authors

Gestational diabetes mellitus (GDM) is a complication of gestation that is characterized by impaired glucose tolerance with first recognition during gestation. It develops when ?- cell of pancreas fail to compensate the diminished insulin sensitivity during gestation. This study aims to investigate the relationship between mother adiponectin level and ?- cell dysfunction with development gestational diabetes mellitus (GDM) and other parameters in the last trimester of pregnancy. This study includes (80) subjects ( pregnant women) in the third trimester of pregnancy, (40) healthy pregnant individuals as control group aged between (17 - 42) years and (40) gestational diabetes mellitus patients with aged between (20 - 42) years. The f

... Show More
View Publication Preview PDF
Crossref
Publication Date
Mon Jul 20 2020
Journal Name
Ibn Al-haitham Journal For Pure And Applied Sciences
Applying Shrinkage Estimation Technique of P(Y<Max X1, X2,…, Xk) in Case of Generalized Exponential Distribution
...Show More Authors

     This paper concerned with estimation reliability (­ for K components parallel system of the stress-strength model with non-identical components which is subjected to a common stress, when the stress and strength follow the Generalized Exponential Distribution (GED) with unknown shape parameter α and the known scale parameter θ (θ=1) to be common. Different shrinkage estimation methods will be considered to estimate ­ depending on maximum likelihood estimator and prior estimates based on simulation using mean squared error (MSE) criteria. The study approved that the shrinkage estimation using shrinkage weight function was the best.

 

View Publication Preview PDF
Crossref (2)
Crossref
Publication Date
Sun Dec 05 2021
Journal Name
Iraqi Journal Of Science
Heavy Metals Pollution Assessment of the Water in Al-Quds Power Plant in Baghdad
...Show More Authors

Sixteen water samples were collected from the operation units of the Al-Quds
power plant, north Baghdad city and the surrounding trocars, surface and
groundwater, and analyzed to assess the resulting pollution. The samples were
analyzed for heavy metals (As, Cd, Cr, Cu, Mn, Mo, Ni, Pb, Sb, Se, U and Zn) by
using inductively coupled plasma- mass spectrometry (ICP-MS). The results were
compared with local and international and standard limits. Heavy metals analysis of
the water samples shows that water of operation units and trocars have mean
concentrations of As, Cd, Cr, Cu, Mo, Pb, Sb, Se, U and Zn were within or lower
than the national and world limits, while Mn and Ni were higher than these limits.
Concentrat

... Show More
View Publication Preview PDF