Thirty six bacteria were isolated from various sourcesc (soil, starch, cooked rice and other foods) and subjected to a series of primary screening tests to obtain the optimal isolation to production of amylase. The volume of producing zone by logal indicator for (Seven) isolates of the secondary screening by measuring the enzymatic activity and specific enzymatic activity. The isolate A4 was found to be the most efficient for production of amylase. Then this isolate was diagnosed through microscopic, vitek 2 system technique. in addition by gentic diagnesis through gene 16s of the genes nitrogen bases by use the polymerase chain reaction (PCR) which reached 1256 bases. In comparison to the available information at the National Center for Biotechnology Information (NCBI), the isolation was found to be Bacillus subtilis
Objective: The present study aims at identifying the dimensions behind juvenile delinquency, and to identify their
socio-demographic characteristics of gender, age, and type of delinquency.
Methodology: A descriptive study was conducted in correctional schools in Baghdad City to identify the
behavioral, psychological, and social dimensions contributed to juvenile delinquency. The study sample consisted
of (50) juvenile delinquents, of them, 27 males, and 23 females whose ages range from (12 - 20) years. Those
delinquents live in males’ correctional school in Al-Shalichia, and females’ correctional school in Al-Karradah, in
Baghdad City. The study sample was selected in purposively. The study questionnaire was design
The present research focuses on the study of the effect of mass transfer resistance on the rate of heat transfer in pool boiling. The nucleate pool boiling heat transfer coefficients for binary mixtures (ethanol-n-butanol, acetone-n-butanol, acetone-ethanol, hexane-benzene, hexane-heptane, and methanol-water) were measured at different concentrations of the more volatile components. The systems chosen covered a wide range of mixture behaviors.
The experimental set up for the present investigation includes electric heating element submerged in the test liquid mounted vertically. Thermocouple and a digital indictor measured the temperature of the heater surface. The actual heat transfer rate being obtained by multiplying the voltme
... Show MoreThe present work provides to treat real oily saline wastewater released from drilling oil sites by the use of electrocoagulation technique. Aluminum tubes were utilized as electrodes in a concentric manner to minimize the concentrations of 113400 mg TDS/L, 65623 mg TSS/L, and the ions of 477 mg HCO3/L, 102000 mg Cl/L and 5600 mg Ca/L presented in real oily wastewater under the effect of the operational parameters (the applied current and reaction time) by making use of the central composite rotatable design. The final concentrations of TDS, TSS, HCO3, Cl, and Ca that obtained were 93555 ppm (17.50%), 11011 ppm (83.22%), 189ppm (60.38%), 80000ppm (22%), and 4200 ppm (25%), respectively, under the optimum values of the operational parameters
... Show MoreSimplifying formulas that are used for calculations and design are the aim of researchers. For present work, the approach to distinguish the flow under sluice gate was conducted in a laboratory. The extensive experimental program was done to collect fifty-four data points for both free and submerged flow conditions. The data included different discharges, gate openings, flow depths at upstream as well as the flow depths represent a tail water and at a contracted section for downstream. The collected data are analyzed according to a problematic that may encounter in the field, to present a more straightforward (but with acceptable accurate) practical features equations and charts. Based on the proposed formulas, five meth
... Show MoreEntropy generation was studied for new type of heat exchanger (shell and double concentric tubes heat exchanger). Parameters of hot oil flow rate, temperature of inlet hot oil and pressure drop were investigated with the concept of entropy generation. The results showed that the value of entropy generation increased with increasing the flow rate of hot oil and when cold water flow rate was doubled from 20 to 40 l/min, these values were larger. On the other hand, entropy generation increased with increasing the hot oil inlet temperature at a certain flow rate of hot oil. Furthermore, at a certain hot oil inlet temperature, the entropy generation increased with the pressure drop at different hot oil inlet flow rates. Final
... Show More
