A new simple and sensitive spectrophotometric method is described for quantification of Nifedipine (NIF) and their pharmaceutical formulation. The selective method was performed by the reduction of NIF nitro group to yield primary amino group using zinc powder with hydrochloric acid. The produced aromatic amine was submitted to oxidative coupling reaction with pyrocatechol and ammonium ceric nitrate to form orange color product measured spectrophotometrically with maximum absorption at 467nm. The product was determined through flow injection analysis (FIA) system and all the chemical and physical parameters were optimized. The concentration range from 5.0 to 140.0 μg.mL-1 was obeyed Beer’s law with a limit of detection and quantitation 1.48 and 4.96 μg.mL-1 respectively. Agoodprecision,low scattering point of the calibration graph and good accuracyin addition, FIA introduced a good linear range with acceptable sensitivity. High correlation coefficient (0.9996) was found. The proposed method was successfully applied to assay NIF and its pharmaceutical dosage also could be utilized for pharmaceutical routine analysis of the drug.
Ischemic heart disease is a major causes of heart failure. Heart failure patients have predominantly left ventricular dysfunction (systolic or diastolic dysfunction, or both). Acute heart failure is most commonly caused by reduced myocardial contractility, and increased LV stiffness. We performed echocardiography and gated SPECT with Tc99m MIBI within 263 patients and 166 normal individuals. Left ventricular end systolic volume (LVESV), left ventricular end diastolic volume (LVEDV), and left ventricular ejection fraction (LVEF) were measured. For all degrees of ischemia, there was a significant difference between ejection fraction values measured by SPECT and echo
Abstract Lateral Epicondylitis (LE) which has been referred to as the Tennis Elbow as well is a lesion affecting common tendinous origins of wrist extensors due to chronic overuse injury that results in damaging common extensor tendons which join forearm extensor muscles to humerus. The aim of the present evidence-based clinical statement is reviewing scientific evidences for efficacy of a variety of the rehabilitation methods, chronic lateral epicondylitis management. It is focused upon treating chronic lateral epicondylitis and the latest developments in physiotherapy area for managing chronic lateral epicondylitis. Due to the fact that primary physical impairments in the LE are decreased is the strength of the grip, fundamentally due to
... Show MoreThe present study aimed to use the magnetic field and nanotechnology in the field of water purification, which slots offering high efficiency to the possibility of removing biological contaminants such as viruses and bacteria rather than the use of chemical and physical transactions such as chlorine and bromine, and ultraviolet light and boiling and sedimentation and distillation, ozone and others that have a direct negative impact on human safety and the environment. Where they were investigating the presence in water samples under study Coli phages using Single agar layer method and then treated samples positive for phages to three types of magnetic field fixed as follows (North Pole - South Pole - Bipolar) and compare the re
... Show MoreSome methods recommended abroad to control the oriental hornet, Vespa orientalis L., attacking the honey bee, Apis mellifera L., colonies were tested, with some modifications, for the first time under the Iraqi conditions. One of these methods was carried out by covering the hive entrance with a piece of queen excluder to prevent the hornet from entering the hive. Also, the position of hive stand was reversed to deprive the hornet from using the flight board as a stage for waiting and creeping toward the defending bees. The second method was carried out by fixing a cardboard cone as a bee passage at the hive entrance to hinder the entry of the hornet into the hive. Both of these methods were found to be unsuccessful to
... Show MoreIn this study, concentrations of Radon were measured for fifty two samples of Fly Ash taken from five thermal power plants in the middle and south of Iraq [Al-Rashed, Al-Dura, Al-Musaeb, Al-Naserya, Al-Basrah (AlHaretha)].
The radon concentrations in samples measured by registrat alpha-emitting radon (222Rn) by using (CR-39) track detector, The concentrations values were calculated by a comparison with standard samples The results shows that the radon concentrations is between (91.931-30.645 Bq/m3)
Background: Atrial fibrillation is the most frequent cardiac arrhythmia encountered in general medicine and cardiology practice. Synchronized direct current shock is a known safe and effective procedure to revert long standing persistent atrial fibrillation into sinus rhythm.
Patients and Methods: Patients with long-standing atrial fibrillation who were seen at the author’s private clinic and Al-Hassani Heart Center in Sulaimanya from April 2018 to December 2020 were chosen for rhythm control subjected to synchronized direct current cardioversion under heavy sedation applying a modified anterolateral paddles position with 200J and 300J successively according to the reversion dose required.
... Show MoreBackground: White-spot lesion is one of the problems associated with the fixed orthodontic treatment. The aims of this in-vitro study were to investigate enamel damage depth on adhesive removal when the adhesive were surrounded by sound, demineralized or demineralized enamel that had been re-mineralized prior to adhesive removal using 10% Nano-Hydroxy apatite and to determine the effect of three different adhesive removal techniques. Materials and methods: Composite resin adhesive (3M Unitek) was bonded to 60 human upper premolars teeth which were randomly divided in to three groups each containing ten sound teeth and ten teeth with demineralized and re-mineralized lesions adjacent to the adhesive. A window of 2 mm was prepared on the bucca
... Show MoreNowadays, most of the on-chip plasmonic single-photon sources emit an unpolarized stream of single photons that demand a subsequent polarizer stage in a practical quantum cryptography system. In this paper, we numerically demonstrated the coupling of the light emitted from a quantum emitter (QE) at 700 nm wavelength to the propagation mode supported by an on-chip hybrid plasmonic waveguide (HPW) polarization rotator. Our results proved that the light emitted is linearly polarized at 0º, 45º/−45º, and 90º with propagation lengths of 5 μm, 3.3 μm, and 3.9 μm, respectively. Moreover, high power-conversion efficiency was obtained from an applied transverse magnetic (TM) mode (0º-polarization) to a transverse electric (TE) (90º-polari
... Show More