This study includes applying chemical tests on cow, sheep and chicken bones including both hallow and flat. The results of chemical tests on bones mentioned the moisture percentage which was between 4.95-7.32 %, and it was noticed the difference in protein percentage among different kinds of bones, The highest protien percentage was 39.62 % in hallow chicken bones and the lowest was in hallow sheep bones 20.31%, at the same time, the highest Ash percentage was in hallow sheep bones48.11% , whereas the highest percentage of fat was in hallow cow bones 30%. The chemical and physical tests were conducted for extracted fat from hallow and flat bones for cows, sheeps and chicken. It was found that peroxide values (PV), and free fatty acids (FFA) tended to increase proportionally with extraction time at temperatures examined. The lowest values ware obtained after 3 hours as PVs were 0.93, 1.2, 1.0, 1.0, 1.33 and 1.46 meq/ kg oil respectively, FFA values were 0.15, 0.168, 0.187, 0.168, 0.206 and 0.225% respectively. The highest chemical indices for extracted fat from hallow and flat bones for cow and sheep was after 5 hours as PVs were 2.39, 1.8, 1.9, and 1.86 meq/ kg oil respectively, FFA values were 0.253, 0.300, 0.263 and 0.30% respectively. While, the highest chemical indices for extracted fat from hallow and flat chicken bones was after 4 hours, as PVs were 1.6 and 1.73 meq/ kg oil respectively, FFA values were 0.245 and 0.244% respectively. The obtained results showed values of smoking point tended to decrease proportionally as extraction time proceeding at different temperature used, highest values were recorded after extraction for 3 hours, smoking point values were 242.6, 231.33, 223.8, 217.66, 204.5and 204 °C respectively. The lowest physical values of fat extracted from hallow and flat bones of cow and sheep were obtained after 5 hours as the smoking point values were 230.33, 229.83, 203.4 and 204.83°C respectively. The lowest physical indices of fat extracted from hallow and flat chicken bones were obtained after 4 hours, as the smoking point values were 204 and 203.5 °C respectively.
A simple, sensitive and accurate spectrophotometric method has been developed for the determination of salbutamol sulphate (SAB) and isoxsuprine hydrochloride (ISX) in pure and pharmaceutical dosage. The method involved oxidation of (SAB) and (ISX) with a known excess of N-bromosuccinamid in acidic medium, and subsequent occupation of unreacted oxidant in decolorization of Evans blue dye (EB). This, in the presence of SAB or ISX was rectilinear over the ranges 1.0-12.0, 1.0-11.0 µg/mL, with molar absorptivity 4.21×104 and 2.58×104 l.mol-1.cm-1 respectively. The developed method had been successfully applied for the determination of the studied drugs in their pharmaceutical dosage resulting i
... Show MoreCefixime (CFX) was treated with sodium nitrite and hydrochloric acid for diazotization reaction followed by coupling with ?-Naphthol in alkaline medium to form, a yellow colored azo dye compound which exhibits maximum absorption (?max) at 412 nm where the concentration of (CFX) was determined spectrophotometrically. The optimum reaction conditions and other analytical parameters were evaluated. Beer’s law was obeyed in the concentration range of (1-20) ?g.mL-1 with a molar absorptivity of 34870.5 L.mol-1.cm-1. The limit of detection was found to be 0.1090 ?g.mL-1 and the Sandell's sensitivity value was 0.0130 ?g.cm-2. The proposed method could be successfully applied to
... Show MoreNicotine was separated from eggplant and green pepper seeds (Solanaceous) by High Performance Liquid Chromatography (HPLC).The concentration of nicotine in the eggplant extract (0.871-0.877 μg/ml) was determined by injecting standard material with 0.5 and 1.5 μg/ml, while the concentrations of nicotine in green pepper extract (0.613-0.618 μg/ml) was determined when the standard material was injected with 0.5 and 1.5 μg/ml. The qualitative chemical data was calculated from derivations of the standard material. Nicotine concentration was measured qualitatively in both extracts through the calibration curve and method of the standard addition. This technique has high accuracy and compatibility, bringing the proportion of relati
... Show MoreSimple, sensitive and accurate two methods were described for the determination of terazosin. The spectrophotometric method (A) is based on measuring the spectral absorption of the ion-pair complex formed between terazosin with eosin Y in the acetate buffer medium pH 3 at 545 nm. Method (B) is based on the quantitative quenching effect of terazosin on the native fluorescence of Eosin Y at the pH 3. The quenching of the fluorescence of Eosin Y was measured at 556 nm after excitation at 345 nm. The two methods obeyed Beer’s law over the concentration ranges of 0.1-8 and 0.05-7 µg/mL for method A and B respectively. Both methods succeeded in the determination of terazosin in its tablets
The human perception of science and knowledge is affected by the personal point of view, thus giving it its religious, mental and emotional dimensions to make that perception an effective tool for realizing the truth comprehensively in the delivery of knowledge to the depths of the human soul. The later is composed of multiple factors, which contributes to the human self-development with dimensions beyond the limits of mental logic and the perception of material and emotional situations. That knowledge in the perception of Islamic virtue, which must characterize each Muslim.
Human beings have been striving for knowledge and the understanding of the universe in which they live. For centuries, mankind has acquired knowledge directly an
During the 2016–2017 and 2017–2018 winter semesters, researchers from the College of Agricultural Engineering Sciences at the University of Baghdad conducted a field experiment at the university’s research station. This inquiry set out to examine how spraying wheat plants with vitamins B9 (Folic acid) and E (Tocopherol) affected certain yield characteristics (Al-Fourat variety). The studies were set up as three repetitions of a factorial experiment using a Randomized Full Block Design. Vitamin E was sprayed at 0, 1, and 2 ml.L-1, while vitamin B9 was sprayed at 0, 1, and 3 ml.L-1 (0, 250, and 500 mg. L-1). While the
new, simple and fast solid-phase extraction method for separation and preconcentration of trace theophylline in aqueous solutions was developed using magnetite nanoparticles (MIONPs) coated with aluminium oxide (AMIONPs) and modified with palmitate (P) as an extractor (P@AMIONPs). It has shown that the developed method has a fast absorbent rate of the theophylline at room temperature. The parameters that affect the absorbent of theophylline in the aqueous solutions have been investigated such as the amount of magnetite nanoparticle, pH, standing time and the volume, concentration of desorption solution. The linear range, limit of quantification (LOQ) and limit of detection (LOD) for the determination of theophylline were 0.05-2.450 μg mL-
... Show MoreThere is no adopt in the importance of the optical communications in scientific civil and military applications because of it’s simplicity in manufacturing and it's low cost. The method of optical communication depends upon bearing the light beam the translated informations by a method called the light modulation. This method depends upon changing some light properties as frequency, amplitude and pulse duration according to the translating informations. The changes in the first two properties are concerned optically with the analog modulation while the third one concern at most with digital modulation. All past methods are expensive with low efficiency and needs electrical or magnetic fields. In this technique the source of voice used
... Show MoreGlobal Navigation Satellite System (GNSS) is considered to be one of the most crucial tools for different applications, i.e. transportation, geographic information systems, mobile satellite communications, and others. Without a doubt, the GNSS has been widely employed for different scientific applications, such as land surveying, mapping, and precise monitoring for huge structures, etc. Thus, an intense competitive has appeared between companies which produce geodetic GNSS hardware devices to meet all the requirements of GNSS communities. This study aims to assess the performance of different GNSS receivers to provide reliable positions. In this study, three different receivers, which are produced by different manufacturers, were fi
... Show More