Preferred Language
Articles
/
jkmc-94
The Immediate And Intermediate Results Of Percutaneous Balloon Aortic Valvuloplasty In Patients With Congenital Valvular Aortic Stenosis
...Show More Authors

Background: Aortic valve stenosis results from minor to severe degrees of aortic valve maldevelopment. This stenosis causes mild to severe obstruction of the left ventricular outflow .

Objectives : to study the immediate and intermediate results of percutaneous balloon aortic valvuloplasty in patients with congenital valvular aortic stenosis .

Type of the study: A prospective study.

Methods: The study was done on thirty five patients with congenital valvular aortic stenosis who had percutaneous balloon aortic valvuloplasty  in Ibn Al- Bitar Center for Cardiac Surgery from May 2009 to February 2011.

Results: Twenty seven patients were male (77.2%) and 8 patients were female (22.8%), male to female ratio 3.5/ 1, . The aortic valve was bicuspid in 18 patients (51.4%) while 17 patients ( 48.6%) had tricuspid aortic valve. Balloon aortic valvuloplasty was successful in 30 patients (85.7%),. Maximum peak instantaneous Doppler pressure gradient across the aortic valve 24 hours postprocedural echocardiography showed reduction which is statistically significant. New aortic regurgitation had occurred in 15 patients ( 42.8%), it was mild in 9 patients ( 25.6%), moderate in 5 patients ( 14.3%) and severe in 1 patient( 2.9%) which is statistically significant. The follow up of 12.57 ± 3.88 ( 3- 22) months after intervention was done for all patients using echocardiography Doppler study, reveal the maximum peak instantaneous Doppler pressure gradient  across the aortic valve was raised  which is statistically significant. The aortic regurgitation was present in 18 patients (51.4%) , it was mild in 9 patients (25.7%) , moderate in 6 patients (17.1%) and severe in 3 patients  ( 8.6%). No mortality had been reported during the procedure or on follow up.

                                                                                 Conclusion: Aortic balloon valvuloplasty is safe and effective procedure in the treatment of congenital valvular aortic stenosis but mild aortic regurgitation is the most common immediate complication of aortic balloon dilatation and progressive aortic regurgitation is a major problem during the intermediate follow up.

                                                                                                                                              

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Wed Jun 01 2022
Journal Name
Baghdad Science Journal
Assessment of Air Pollution around Durra Refinery (Baghdad) from Emission NO2 Gas at April Month
...Show More Authors

Nitrogen dioxide NO2 is one of the most dangerous contaminant in the air, its toxic gas that cause disturbing respiratory effects, most of it emitted from industrial sources especially from the stack of power plants and oil refineries. In this study Gaussian equations modelled by Matlab program to state the effect of pollutant NO2 gas on area around Durra refinery, this program also evaluate some elements such as wind and stability and its effect on stacks height. Data used in this study is the amount of fuel oil and fuel gas burn inside refinery at a year 2017. Hourly April month data chosen as a case study because it’s unsteady month. After evaluate emission rate of the all fuel and calculate exit velocity from

... Show More
View Publication Preview PDF
Scopus (16)
Crossref (4)
Scopus Clarivate Crossref
Publication Date
Wed Oct 09 2024
Journal Name
Engineering, Technology & Applied Science Research
Experimental Investigation of Composite Circular Encased GFRP I-Section Concrete Columns under Different Load Conditions
...Show More Authors

Pultruded materials made of Fiber-Reinforced Polymer (FRP) come in a broad range of shapes, such as bars, I-sections, C-sections, etc. FRP materials are starting to compete with steel as structural materials owing to their great resistance, low self-weight, and cheap maintenance costs, especially in corrosive conditions. This study aims to evaluate the effectiveness of a novel concrete Composite Column (CC) using Encased I-Section (EIS) as a reinforcement in contrast to traditional steel bars by using Glass Fiber-Reinforced Polymer (GFRP) as I-section (CC-EIS) to evaluate the effectiveness of the hybrid columns which have been built by combining GFRP profiles with concrete columns. To achieve the aims of this study, nine circular co

... Show More
View Publication
Scopus (5)
Crossref (5)
Scopus Crossref
Publication Date
Mon Apr 01 2019
Journal Name
Journal Of Engineering
Removal of Methyl Orange from Aqueous Solutions by Adsorption Using Corn Leaves as Adsorbent Material
...Show More Authors

A comparative study was done on the adsorption of methyl orange dye (MO) using non-activated and activated corn leaves with hydrochloric acid as an adsorbent material. Scanning electron microscopy (SEM) and Fourier Transform Infrared spectroscopy (FTIR) were utilized to specify the properties of adsorbent material. The effect of several variables (pH, initial dye concentration, temperature, amount of adsorbent and contact time) on the removal efficiency was studied and the results indicated that the adsorption efficiency increases with the increase in the concentration of dye, adsorbent dosage and contact time, while inversely proportional to the increase in pH and temperature for both the treated and untreated corn leaves. The equi

... Show More
View Publication
Crossref (20)
Crossref
Publication Date
Sat Jan 01 2022
Journal Name
Journal Of Advanced Pharmacy Education And Research
Co-surfactant effect of polyethylene glycol 400 on microemulsion using BCS class II model drug
...Show More Authors

View Publication
Scopus (31)
Crossref (26)
Scopus Crossref
Publication Date
Sun Jan 01 2023
Journal Name
Alexandria Engineering Journal
Calcium/iron-layered double hydroxides-sodium alginate for removal of tetracycline antibiotic from aqueous solution
...Show More Authors

Crossref (34)
Crossref
Publication Date
Mon Jan 01 2024
Journal Name
Ieee Access
A Magnetic Field Concentration Method for Magnetic Flux Leakage Detection of Rail-Top Surface Cracks
...Show More Authors

View Publication
Scopus (8)
Crossref (8)
Scopus Clarivate Crossref
Publication Date
Mon Jun 01 2020
Journal Name
Iop Conference Series: Materials Science And Engineering
Removal of COD from Petroleum refinery Wastewater by Electro-Coagulation Process Using SS/Al electrodes
...Show More Authors
Abstract<p>In the present study, the effectiveness of a procedure of electrocoagulation for removing chemical oxygen demand (COD) from the wastewater of petroleum refinery has been evaluated. Aluminum and stainless steel electrodes were used as a sacrificial anode and cathode respectively. The effect of current density (4-20mAcm<sup>−2</sup>), pH (3-11), and NaCl concentration (0-4g/l) on efficiency of removal of chemical oxygen demand was investigated. The results have shown that increasing of current density led to increase the efficiency of COD removal while increasing NaCl concentration resulted in decreasing of COD removal efficiency. Effect of pH was found to be lowering COD re</p> ... Show More
View Publication
Scopus (37)
Crossref (23)
Scopus Crossref
Publication Date
Thu Nov 07 2024
Journal Name
Journal Of Ecological Engineering
Microwave assisted production of biodiesel using CaO nano-catalyst produced from mango fallen leaves extract
...Show More Authors

View Publication
Scopus (4)
Crossref (3)
Scopus Crossref
Publication Date
Mon Dec 31 2012
Journal Name
Al-khwarizmi Engineering Journal
Genetic Algorithm Based PID Controller Design for a Precise Tracking of Two-Axis Piezoelectric Micropositioning Stage
...Show More Authors

 In this paper, an intelligent tracking control system of both single- and double-axis Piezoelectric Micropositioner stage is designed using Genetic Algorithms (GAs) method for the optimal Proportional-Integral-Derivative (PID) controller tuning parameters. The (GA)-based PID control design approach is a methodology to tune a (PID) controller in an optimal control sense with respect to specified objective function. By using the (GA)-based PID control approach, the high-performance trajectory tracking responses of the Piezoelectric Micropositioner stage can be obtained. The (GA) code was built and the simulation results were obtained using MATLAB environment. The Piezoelectric Micropositioner simulation model with th

... Show More
View Publication Preview PDF
Publication Date
Wed Jul 01 2015
Journal Name
Journal Of Engineering
Optimal Location of Static Synchronous Compensator (STATCOM) for IEEE 5-Bus Standard System Using Genetic Algorithm
...Show More Authors

Heuristic approaches are traditionally applied to find the optimal size and optimal location of Flexible AC Transmission Systems (FACTS) devices in power systems. Genetic Algorithm (GA) technique has been applied to solve power engineering optimization problems giving better results than classical methods. This paper shows the application of GA for optimal sizing and allocation of a Static Compensator (STATCOM) in a power system. STATCOM devices used to increase transmission systems capacity and enhance voltage stability by regulate the voltages at its terminal by controlling the amount of reactive power injected into or absorbed from the power system. IEEE 5-bus standard system is used as an example to illustrate the te

... Show More
View Publication Preview PDF