Preferred Language
Articles
/
jkmc-93
Predictors of poor first trimester outcome in asymptomatic women : the value of embryonic heart rate , mid sac diameter / yolk sac ratio & mid sac diameter / crown rump length
...Show More Authors

Background:  Ultrasound provides a powerful tool for assessing early pregnancy and detecting pregnancy failure at first trimester and promoting rapid effective management. Several  criteria have been established  to predict  the pregnancy outcome particularly in symptomatic women .

Aim: To evaluate  asymptomatic women at the first trimester of pregnancy , to assess the efficacy of certain ratios as mid sac diameter (MSD)  / yolk sac ratio & crown rump length (CRL)/mid sac diameter (as indicator  of early first trimester oligohydramnios)  in predicting poor 1st   trimester outcome

Type of the study: A cross-sectional study.

Patients & Methods:  A sixty three asymptomatic women were enrolled in this prospective study . Transvaginal sonography was performed for confirmation of pregnancy viability & exclusion of multiple pregnancies 6-8 weeks of gestation & follow up ultrasound repeated at the beginning of second trimester to confirm the continuation of pregnancy and  viability of fetus. Several parameters assessed and tested against each others as embryonic heart rate , the size and morphologic criteria of gestational sac , yolk sac and  the crown rump length 

Results: The women  were classified into two groups: group A are those with successful outcome at the first trimester and group B are those with poor outcome of the 1st trimester . Decrease embryonic heart rate below 100 beat per minute  and low mid sac diameter/ yolk sac size ratio of < 1.9 , were found to be significant predictors of poor outcome however mid sac diameter/crown rump length ratio was not found to  have a similar significance 

Conclusion: In addition to the classical parameters  assessed  by trans-vaginal ultrasound, other important parameters need to be routinely applied as the  embryonic heart rate that predict poor outcome when less than 100 bpm . In addition to the ratio of mid sac diameter to the yolk sac diameter which  , if less than 1.9 ,  may point to abnormal  first trimester fate.

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Sat Dec 01 2018
Journal Name
Journal Of South Asian Federation Of Obstetrics And Gynaecology
Effect of Leptin Level in Pregnancy Complicated by Preeclampsia and Pregnancy Outcome
...Show More Authors

View Publication
Scopus Crossref
Publication Date
Mon Jan 29 2024
Journal Name
Al-rafidain Journal Of Medical Sciences ( Issn 2789-3219 )
Role of Ultrasound in Antenatal Detection of Echogenic Amniotic Fluid and Pregnancy Outcome
...Show More Authors

Background: Ultrasound is a valuable tool for evaluating fetal problems throughout pregnancy. Amniotic fluid anomalies have been associated with unfavorable maternal, fetal, and obstetrical outcomes. Objective: To determine the effect of echogenic amniotic fluid during term pregnancy on the presence of meconium stain liquor and pregnancy outcome. Methods: A cross-sectional study was conducted on 1080 term pregnant women who visited Al-Elwiya Maternity Teaching Hospital from May 1st, 2021, to May 1st, 2023. Ultrasound was used to analyze echogenic amniotic fluid and turbid liquor. The liquor state was tested either after an artificial membrane rupture in the vaginal delivery trial or during a cesarean section. Results: Echogenic amni

... Show More
View Publication Preview PDF
Scopus (1)
Scopus Crossref
Publication Date
Fri Dec 30 2022
Journal Name
Journal Of The College Of Education For Women
The Existential Psychological Crisis Among Battered Women to Non-Battered Women in the Republic of Yemen
...Show More Authors

The research deals with a very important issue that affects women, an important segment of the society. This is because women are the basis of the family and the pillar of the society. Thus, the aim of the research is to examine the level and dimensions of the emotional and existential psychological crisis at the sample of the study. It further aims to investigate the statistical significant difference at the level of (0.05) regarding the feeling of the existential psychological crisis among battered and non-battered women. To reveal the objectives of the study, the researcher applied the existential psychological crisis scale to a sample of (72) women, divided into two groups: (35) battered women, who have been chosen purposefully. Thos

... Show More
View Publication Preview PDF
Crossref
Publication Date
Fri Dec 30 2011
Journal Name
Al-kindy College Medical Journal
Excessive crying in infancy; value of the history and physical examination
...Show More Authors

Background: Excessive crying in early
infancy is a common condition that causes a
great deal of concern to the parents and
physician.
Objective: The aim of this study is to find
the underlying etiology of excessive crying in
infancy and to determine how the history,
physical examination, and laboratory
investigations contribute to the final diagnosis.
Method: A prospective study done on 150
afebrile infants less than 4 months of age
visited Al-Elwia hospital for children
complaining of excessive crying of more than
two hours.
The study done over a one year period from
the first of January 2009 to the end of
December 2009.
All febrile infants and those with acute illness
preceding the

... Show More
View Publication Preview PDF
Publication Date
Fri Sep 15 2023
Journal Name
Journal Of Baghdad College Of Dentistry
FEM: Mono-implant cement retained crown with two different adhesive materials
...Show More Authors

Background: The finite element method (FEM) is expected to be one of the most effective computational tools for measuring the stress on implant-supported restorations. This study was designed using the 3D-FEM to evaluate the effect of two adhesive luting types of cement on the occlusal stress and deformation of a hybrid crown cemented to a mono-implant. Materials and Method: The mono-screw STL file was imported into the CAD/CAM system library from a database supported by De-Tech Implant Technology. This was to assist in the accurate reproduction of details and design of a simulated implant abutment. Virtually, a digital crown was designed to be cemented on an abutment screw. A minimum occlusal thickness of 1mm and marginal fitting of 1.2

... Show More
View Publication Preview PDF
Scopus (2)
Crossref (2)
Scopus Crossref
Publication Date
Fri Dec 01 2023
Journal Name
Iop Conference Series: Earth And Environmental Science
Relationship Study Between Total Length with Otolith Length and Thickness in Two Fish Species: Coptodon zillii (Gervais,1848) and Cyprinus carpio” (Linnaeus,1758)
...Show More Authors
Abstract<p>This study aimed new indications that may clarify the relationships between the total and standard lengths, and the length of the otolith, as well as the thickness and weight of these bones compared to the body weights of two different species of invasive fish in the Iraqi aquatic environment, the common carp <italic>Cyprinus carpio</italic> of the Cyprinidae family, and the common Tilapia. <italic>Coptodon zillii</italic>, from the Cichlidae family. The results showed that the otolith were not related to some of the vital characteristics of the studied fish, and there were differences in the correlation coefficient between some vital measurements with high signifi</p> ... Show More
View Publication Preview PDF
Scopus (2)
Crossref (2)
Scopus Crossref
Publication Date
Mon May 30 2022
Journal Name
The Journal Of Infection In Developing Countries
SARS-CoV-2 viral shedding and susceptibility: perspectives on gender and asymptomatic patients
...Show More Authors

Despite efforts to contain and manage the SARS-CoV-2 outbreak which was declared a public health emergency of international concern in January 2020 by the World Health Organization (WHO), the COVID-19 pandemic still remains a major global challenge. Patients who display the classical symptoms of the infection are easily identified, tested, isolated and monitored. However, many cases of infected asymptomatic patients have been documented. These patients are not easily identified even though many evidences suggest that they can spread the virus to others. How and why these COVID-19 asymptomatic presentations occur remain unclear. The many theories and views are conjectural, and supporting evidences are still needed. In this review, we

... Show More
View Publication
Scopus (3)
Crossref (4)
Scopus Clarivate Crossref
Publication Date
Fri Jun 30 2006
Journal Name
Al-kindy College Medical Journal
Serum Zinc Level in Patients with Heart Failure
...Show More Authors

Background: Zinc is involved in a variety of
metabolic processes and it has a well known
antioxidant activity, so the measurement of its serum
level can have a special value in several diseases.
Objectives: The study is designed to determine the
serum zinc level in heart failure patients and to
compare it with that of healthy individuals and to
study the significance of the results obtained.
Methods: Atomic absorption spectrometer
technique was used to determine serum zinc level in
fifty heart failure patients and fifty healthy individuals
who were age and sex matched.
Results: The mean serum zinc level in healthy
individuals was about 45.5% greater than that of heart
failure patients. This diffe

... Show More
View Publication Preview PDF
Publication Date
Mon Oct 01 2018
Journal Name
Iraqi Journal Of Physics
Simulations of the initiation and propagation of streamers in electrical discharges inside water at 3 mm length gap
...Show More Authors

This work is devoted to the modeling of streamer discharge, propagation in liquid dielectrics (water) gap using the bubble theory. This of the electrical discharge (streamer) propagating within a dielectric liquid subjected to a divergent electric field, using finite element method (in two dimensions). Solution of Laplace's equation governs the voltage and electric field distributions within the configuration, the electrode configuration a point (pin) - plane configuration, the plasma channels were followed, step to step. The results show that, the electrical discharge (streamer) indicates the breakdown voltage required for a 3mm atmospheric pressure dielectric liquid gap as 13 kV. Also, the electric potential and field distributions sho

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sun Feb 03 2019
Journal Name
Journal Of The College Of Education For Women
The Relationship between the age of the pregnant mother and the values hemoglobin blood and packed cell volume (PCV) in the Third Trimester for different age groups (descriptive study)
...Show More Authors

Pregnancy pose an additional burden on the body of the mother so as to meet their needs and the needs of the fetus and the body's need to iron increases excessively during pregnancy and iron is an essential element for the formation of hemoglobin blood Either hemoglobin is the key ingredient for red blood cells which carries oxygen to parts of the body, alas, most of the pregnant women begin their pregnancy inadequate stocks of iron in their bodies, which does not cover their need and requirement of the fetus, especially in the second and third trimesters of pregnancy When you reach the mother to the period in which they did not have the adequate amount of iron to produce hemoglobin become the mother was anemic So emerged the problem of

... Show More
View Publication Preview PDF