Preferred Language
Articles
/
jkmc-802
Ultrasound Guided Core Needle Biopsy in The Diagnosis of Suspicious Breast Lesions: Radiologist’s perspectives
...Show More Authors

Background: Ultrasound guided core needle biopsy is becoming a gold standard in the work up of suspicious breast lesion. In Iraq, radiologists are not taking the lead in core needle biopsy performance.

Objectives: To evaluate the radiologist performance of core needle biopsy highlighting the precession and accuracy of the procedure, the concordance of ultrasound and histopathology, and identifying challenges facing the radiologist during the procedure.

Subjects and Methods: A prospective study involving a total of 50 patients with ultrasound (US) BIRADS IV or V.  Ultrasound guided core needle biopsy was performed for each patient. Surgical pathology diagnosis was available for 40 patients.  core needle biopsy results were correlated with Breast Imaging-Reporting and Data System (BI-RADS) categories and validity of the test was evaluated.

Results: Malignancy was confirmed by histopathology in 76% of the cores. Concordance between BI-RADS(US) and histopathology for benignity and malignancy was achieved in all cores. Borderline lesions constituted 10% of total cores taken. Surgical resection of these lesions upgraded 3/5 (60%): two atypical ductal hyperplasia and an intraductal papillary lesions diagnosed by core needle biopsy found to be invasive ductal carcinoma after surgical resection.  Sensitivity of core needle biopsy in this study was 91.4% with 100% specificity. Positive and negative predictive values were 100% and 62.5% respectively. The underestimation rate in high-risk group was 3/5 (60%). No significant complication was reported.

Conclusion:  Ultrasound guided core needle biopsy is a safe, efficient and relatively inexpensive method in diagnosing suspicious breast lesions. Radiologists can produce high sensitivity and specificity results.  Radio pathological correlation is of paramount in achieving accurate results.

Scopus Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Tue Mar 05 2024
Journal Name
Journal Of Economics And Administrative Sciences
The Role of Quality of Work Life in Reinforcing Core Competencies: A Descriptive and analytical research in the Ministry of Health
...Show More Authors

يهدف البحث إلى تشخيص أوجه القصور ونقاط الضعف في تطبيق أبعاد جودة الحياة الوظيفية ومدى تأثيرها على اتجاهات وسلوكيات الموظفين، وبالتالي علاقتها بتعزيز مقدراتهم الجوهرية. وتنبع القيمة العلمية للبحث من إبراز أهمية أبعاد جودة حياة العمل في تحسين الكفاءة الإنتاجية للعاملين في القطاع العام ورفع مستوى الأداء التنظيمي. ولأن جودة الحياة العملية تلعب دوراً مهماً في تعزيز المقدرات الأساسية للموظفين في القطاع الع

... Show More
Crossref
Publication Date
Sat Dec 30 2023
Journal Name
Journal Of Economics And Administrative Sciences
The Role of Quality of Work Life in Reinforcing Core Competencies: A Descriptive and analytical research in the Ministry of Health
...Show More Authors

The research aims to diagnose the shortcomings and weaknesses in applying the dimensions of the quality of work life and the extent of their impact on employees’ attitudes and behaviors, and thus their relationship to enhancing their core competencies. The scientific value of the research stems from highlighting the importance of the dimensions of the quality of professional life in improving the productive efficiency of workers in the public sector and raising the level of organizational performance. Because the quality of working life plays an important role in enhancing the core competencies of employees in the public sector, it can also be an incentive or a disincentive for any employee by adapting to the economic and social condition

... Show More
Publication Date
Thu Aug 10 2023
Journal Name
Central Asian Journal Of Medical And Natural Sciences
Role of Gamma Camera Components in Radiological Diagnosis
...Show More Authors

The gamma camera, along with SPECT and PET scanners, is one of the main imaging technologies in nuclear medicine. A collimator is typically constructed from tungsten to provide high absorption of gamma photon energies. It has a hole or holes for imaging. Gamma rays from a radioactive source within the body are emitted in all directions, while the photons required constructing an image travel through the hole. A scintillator is the most common material used to convert the high energy of gamma radiation into a lowenergy optical photon. These detectors are one of the primary secrets to radio-diagnosis in nuclear medicine. The photomultiplier tube (PMT) is a versatile device with extraordinarily highly sensitivity and response. A typical photom

... Show More
Publication Date
Mon Jun 30 2014
Journal Name
Al-kindy College Medical Journal
Ultrasound assessment of normal splenic length and spleen to left kidney ratio in sample of Iraqi population
...Show More Authors

Background: Spleen is a hemopoietic organ which is capable of supporting elements of different systems. It is affected by several groups of diseases; inflammatory, hematopoietic, reticuloendothelial proliferation, portal hypertension and storage diseases. Ultrasound (US) may detect mild splenomegaly before it is clinically palpable. Knowledge of the normal range of spleen size in the population being examined is a prerequisite. Racial differences in splenic length could result in incorrect interpretation of splenic measurements and such differences would make it difficult to standardize expected splenic length and to determine non- palpable splenic enlargement.Objectives: To measure the normal values of splenic lengthin Iraqi subjects an

... Show More
View Publication Preview PDF
Publication Date
Mon Jan 29 2024
Journal Name
Al-rafidain Journal Of Medical Sciences ( Issn 2789-3219 )
Role of Ultrasound in Antenatal Detection of Echogenic Amniotic Fluid and Pregnancy Outcome
...Show More Authors

Background: Ultrasound is a valuable tool for evaluating fetal problems throughout pregnancy. Amniotic fluid anomalies have been associated with unfavorable maternal, fetal, and obstetrical outcomes. Objective: To determine the effect of echogenic amniotic fluid during term pregnancy on the presence of meconium stain liquor and pregnancy outcome. Methods: A cross-sectional study was conducted on 1080 term pregnant women who visited Al-Elwiya Maternity Teaching Hospital from May 1st, 2021, to May 1st, 2023. Ultrasound was used to analyze echogenic amniotic fluid and turbid liquor. The liquor state was tested either after an artificial membrane rupture in the vaginal delivery trial or during a cesarean section. Results: Echogenic amni

... Show More
View Publication Preview PDF
Scopus (2)
Crossref (1)
Scopus Crossref
Publication Date
Mon Jan 01 2018
Journal Name
Journal Of Global Pharma Technology
Detection of HBME-1 and galectin-3 by immunohistochemistry in follicular lesions
...Show More Authors

The main problem established by a discovery of a thyroid nodule is to discriminate between a benign and malignant lesion. Differential diagnosis between follicular thyroid cancer (FTC) and benign follicular thyroid adenoma (FTA) is a great challenge for even an experienced pathologist and requires special effort. A developing number of some encouraging IHC markers for the differential diagnosis of thyroid lesions have emerged, including, Hector Battifora mesothelial (HBME-1) and galectin-3 (Gal-3). There was significant positive correlation between Galectin-3 and HBME-1 in follicular carcinoma and follicular variant of papillary carcinoma (r= 0.380, P= 0.041) and (r= 0.315, P=0.047) respectively. There was no significant correlation between

... Show More
Scopus
Publication Date
Wed Oct 07 2020
Journal Name
Indian Journal Of Forensic Medicine & Toxicology
Carbon Dioxide Laser in the Treatment of Oral and Craniofacial Soft Tissue Lesions, Pros and Cons
...Show More Authors

Background and objectives: Whether to use a cold scalpel or laser surgery to remove a lesion in the skin of the craniofacial area is the main question the surgeon asks him- or herself to do. The study tried to extend the literature with data that may help the surgeons to choose the right method. Methods: Thirty patients with intra- and extraoral craniofacial skin lesions managed by Carbone dioxide (CO2) laser surgery. Results: The most common type of lesion treated was melanocytic nevi (15 patients; 50%). Conclusion: The main complication of CO2 laser surgery is the remaining permanent hypopigmentation of the treated area; however, the CO2 laser has many advantages (especially at the time of surgery) making it a good choice for the manageme

... Show More
View Publication
Scopus (2)
Scopus Crossref
Publication Date
Fri Dec 31 2021
Journal Name
Political Sciences Journal
Alternative Perspectives in Explaining the Conduct of US Foreign Policy: A Historical-Critical View of Decision-Making Models
...Show More Authors

Receipt date:2/17/2021 acceptance date:3/16/2021 Publishing date:12/31/2021

Creative Commons LicenseThis work is licensed under a Creative Commons Attribution 4.0 International License.

Objective: This paper investigates the contradictions in the decision-making process of the United States, which historically proven to be successful policies in the short term, but in the long term proven to be wanting and failure. Methodology: The paper uses descriptive, historical, comparative method. A

... Show More
View Publication Preview PDF
Crossref
Publication Date
Fri Dec 31 2021
Journal Name
Iraqi Journal Of Laser
The influence of no-core fibre length on the sensitivity Optical fibre Humidity sensor
...Show More Authors

Abstract: Reflection optical fibre Humidity sensor is presented in this work, which is based on no core fibre prepared by splicing a segment of no core fibre (NCF) at different lengths 1-6 cm with fixed diameter 125 µm and a single mode fibre (SMF). The range of humidity inside the chamber is controlled from 30% to 90% RH at temperature ~ 30 °С. The experimental result shows that the resonant wavelength dip shift decreases linearly with an increment of RH% and the sensitivity of the sensor increased linearly with an increasing in the length of NCF. However, a high sensitivity 716.07pm/RH% is obtained at length 5cm with good stability and reputability.  Furthermore, the sensor is shif

... Show More
View Publication Preview PDF
Publication Date
Thu Jan 30 2020
Journal Name
Al-kindy College Medical Journal
Comparison between the Patterns of Common Breast Diseases Presenting as Breast Lumps in Pregnant and Non-Pregnant Married Women
...Show More Authors

Background: Breast lump is one of the most common prevalent complaint of patients attending breast clinics.

Objective: To determine if there is any change in the pattern of common breast, diseases presenting as breast lumps between pregnant and non-pregnant women among patients attending Al-Elwiya Breast Clinic.

Methods: This is a cross – sectional study, with convent's patient sampling setting in AL-Elwiya Breast Cancer Early Detection Clinic from 1st Feb. to 1st May 2018, we collected data from patients with breast lumps including the age groups, pregnancy status, parity status, previous breast diseases, hormonal drugs, menstrual cycle, breast fe

... Show More
View Publication Preview PDF
Crossref