Preferred Language
Articles
/
jkmc-802
Ultrasound Guided Core Needle Biopsy in The Diagnosis of Suspicious Breast Lesions: Radiologist’s perspectives
...Show More Authors

Background: Ultrasound guided core needle biopsy is becoming a gold standard in the work up of suspicious breast lesion. In Iraq, radiologists are not taking the lead in core needle biopsy performance.

Objectives: To evaluate the radiologist performance of core needle biopsy highlighting the precession and accuracy of the procedure, the concordance of ultrasound and histopathology, and identifying challenges facing the radiologist during the procedure.

Subjects and Methods: A prospective study involving a total of 50 patients with ultrasound (US) BIRADS IV or V.  Ultrasound guided core needle biopsy was performed for each patient. Surgical pathology diagnosis was available for 40 patients.  core needle biopsy results were correlated with Breast Imaging-Reporting and Data System (BI-RADS) categories and validity of the test was evaluated.

Results: Malignancy was confirmed by histopathology in 76% of the cores. Concordance between BI-RADS(US) and histopathology for benignity and malignancy was achieved in all cores. Borderline lesions constituted 10% of total cores taken. Surgical resection of these lesions upgraded 3/5 (60%): two atypical ductal hyperplasia and an intraductal papillary lesions diagnosed by core needle biopsy found to be invasive ductal carcinoma after surgical resection.  Sensitivity of core needle biopsy in this study was 91.4% with 100% specificity. Positive and negative predictive values were 100% and 62.5% respectively. The underestimation rate in high-risk group was 3/5 (60%). No significant complication was reported.

Conclusion:  Ultrasound guided core needle biopsy is a safe, efficient and relatively inexpensive method in diagnosing suspicious breast lesions. Radiologists can produce high sensitivity and specificity results.  Radio pathological correlation is of paramount in achieving accurate results.

Scopus Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Fri Aug 20 2021
Journal Name
Iraqi Journal Of Laser
The Influence of No-Core Fiber Length on the Sensitivity in Fiber Optic Strain Sensor
...Show More Authors

The influence of sensing element length of no-core fiber strain sensor has been studied and experimentally demonstrated, four different lengths of 125 μm diameter no-core fiber is fused between two standard single-mode fibers and bi-directionally strained, the highest obtained sensitivity was around 16.37 pm με -1 which was exhibited in the shortest no-core fiber segment, to the best of our knowledge this is the first study of the influence of no-core fiber strain sensors length on sensor sensitivity. The proposed sensor can be used in many opto-mechanical applications such as, structural health monitoring, aerospace vehicles and airplane components monitoring.

View Publication Preview PDF
Publication Date
Mon Jan 29 2024
Journal Name
Al-rafidain Journal Of Medical Sciences ( Issn 2789-3219 )
Role of Ultrasound in Antenatal Detection of Echogenic Amniotic Fluid and Pregnancy Outcome
...Show More Authors

Background: Ultrasound is a valuable tool for evaluating fetal problems throughout pregnancy. Amniotic fluid anomalies have been associated with unfavorable maternal, fetal, and obstetrical outcomes. Objective: To determine the effect of echogenic amniotic fluid during term pregnancy on the presence of meconium stain liquor and pregnancy outcome. Methods: A cross-sectional study was conducted on 1080 term pregnant women who visited Al-Elwiya Maternity Teaching Hospital from May 1st, 2021, to May 1st, 2023. Ultrasound was used to analyze echogenic amniotic fluid and turbid liquor. The liquor state was tested either after an artificial membrane rupture in the vaginal delivery trial or during a cesarean section. Results: Echogenic amni

... Show More
View Publication Preview PDF
Scopus (1)
Scopus Crossref
Publication Date
Sat Dec 30 2023
Journal Name
Journal Of Economics And Administrative Sciences
The Role of Quality of Work Life in Reinforcing Core Competencies: A Descriptive and analytical research in the Ministry of Health
...Show More Authors

The research aims to diagnose the shortcomings and weaknesses in applying the dimensions of the quality of work life and the extent of their impact on employees’ attitudes and behaviors, and thus their relationship to enhancing their core competencies. The scientific value of the research stems from highlighting the importance of the dimensions of the quality of professional life in improving the productive efficiency of workers in the public sector and raising the level of organizational performance. Because the quality of working life plays an important role in enhancing the core competencies of employees in the public sector, it can also be an incentive or a disincentive for any employee by adapting to the economic and social condition

... Show More
Publication Date
Tue Mar 05 2024
Journal Name
Journal Of Economics And Administrative Sciences
The Role of Quality of Work Life in Reinforcing Core Competencies: A Descriptive and analytical research in the Ministry of Health
...Show More Authors

يهدف البحث إلى تشخيص أوجه القصور ونقاط الضعف في تطبيق أبعاد جودة الحياة الوظيفية ومدى تأثيرها على اتجاهات وسلوكيات الموظفين، وبالتالي علاقتها بتعزيز مقدراتهم الجوهرية. وتنبع القيمة العلمية للبحث من إبراز أهمية أبعاد جودة حياة العمل في تحسين الكفاءة الإنتاجية للعاملين في القطاع العام ورفع مستوى الأداء التنظيمي. ولأن جودة الحياة العملية تلعب دوراً مهماً في تعزيز المقدرات الأساسية للموظفين في القطاع الع

... Show More
Crossref
Publication Date
Sat May 01 2021
Journal Name
Journal Of Physics: Conference Series
Design of Optical Fibers and Calculate their Guided Modes Properties at 1550 nm
...Show More Authors
Abstract<p>There is no doubt that optical fiber technology is one of the most important stages of the communications revolution at all and it is of utmost importance in our daily life. In this work, five fibers with core radii 2.5, 4.5 and 6.5–8.5 μm were designed. The properties of all guided modes have been calculated at a wavelength of 1550 nm by using RP Fiber Calculator. A single-mode fiber is obtained when the core radius approaches the wavelength. As the core radius is increased, the fiber becomes a multimode. The percentage power in the core increases with increasing core radius. The modes profiles were illustrated and compared with the modern references.</p>
View Publication
Scopus (3)
Crossref (2)
Scopus Crossref
Publication Date
Mon Jan 01 2018
Journal Name
Journal Of Cosmetics, Dermatological Sciences And Applications
Treatment of Patients with Vitiligo by Intradermal Pricking of Vitiligenous Skin Using Sharp and Blunt Needle
...Show More Authors

View Publication
Crossref
Publication Date
Sun Mar 29 2020
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Oxidation Desulphurization of Heavy Naphtha Improved by Ultrasound Waves
...Show More Authors

The oxidation desulphurization assisted by ultrasound waves was applied to the desulphurization of heavy naphtha. Hydrogen peroxide and acetic acid were used as oxidants, ultrasound waves as phase dispersion, and activated carbon as solid adsorbent. When the oxidation desulphurization (ODS) process was followed by a solid adsorption step, the performance of overall Sulphur removal was 89% for heavy naphtha at the normal condition of pressure and temperature. The process of (ODS) converts the compounds of Sulphur to sulfoxides/ sulfones, and these oxidizing compounds can be removed by activated carbon to produce fuel with low Sulphur content. The absence of any components (hydrogen peroxide, acetic acid, ultrasound waves and activated car

... Show More
View Publication Preview PDF
Crossref (3)
Crossref
Publication Date
Thu Jun 30 2011
Journal Name
Al-kindy College Medical Journal
The Expression of Epstein-Barr virus in Breast cancer in relation to age
...Show More Authors

Background: Breast cancer is the most common
malignancy affecting females worldwide. The association
of Epstein-Barr virus (EBV) with this cancer is a longstanding
interest to this field.
Aim: to investigate the presence of EBV in breast tumor
tissue in relation to age.
Patients and Methods: Paraffin-embedded tissue blocks
from 45 female patients with breast tumors (ranged in age
from 28 to 85 years) were retrieved. The cases were
grouped into two categories: group (A): included 30 cases
with breast carcinoma and group (B): included 15 cases
with benign breast diseases as a control group .The
expression of EBV protein was examined
immunohistochemically.
Results: Twelve (40%) of the 30 breast canc

... Show More
View Publication Preview PDF
Publication Date
Fri Dec 31 2021
Journal Name
Iraqi Journal Of Laser
The influence of no-core fibre length on the sensitivity Optical fibre Humidity sensor
...Show More Authors

Abstract: Reflection optical fibre Humidity sensor is presented in this work, which is based on no core fibre prepared by splicing a segment of no core fibre (NCF) at different lengths 1-6 cm with fixed diameter 125 µm and a single mode fibre (SMF). The range of humidity inside the chamber is controlled from 30% to 90% RH at temperature ~ 30 °С. The experimental result shows that the resonant wavelength dip shift decreases linearly with an increment of RH% and the sensitivity of the sensor increased linearly with an increasing in the length of NCF. However, a high sensitivity 716.07pm/RH% is obtained at length 5cm with good stability and reputability.  Furthermore, the sensor is shif

... Show More
View Publication Preview PDF
Publication Date
Tue Mar 15 2022
Journal Name
Journal Of Baghdad College Of Dentistry
Effect of Resin Infiltration and Microabrasion on the Microhardness of the Artificial White Spot Lesions (An in Vitro Study)
...Show More Authors

Crossref (3)
Crossref