Preferred Language
Articles
/
jkmc-797
Safety profile of immediate post-partum intrauterine device insertion during caesarean delivery – a clinical trial with three years of follow up: Utility of Immediate Post Placental Insertion of Intrauterine Device During Cesarean Delivery
...Show More Authors

Background: Many countries recommend the use of long-acting reversible contraceptive intrauterine device immediately after cesarean delivery. The cesarean delivery rate in Iraqi public hospitals is 32.2% and may reach 85.8% in private hospitals. Immediate post-partum intrauterine device insertion at cesarean is rarely done in Iraq.

Objectives: To assess the safety and practicality of immediate post-partum intrauterine device insertion during cesarean delivery for family planning and pregnancy spacing in Iraqi women.

Subjects and Methods: A single arm clinical trial included 150 eligible women who attended Al-‎Elwiyah Maternity Teaching Hospital or Al Hayat Rahibat Hospital for term delivery. A copper intrauterine device was placed in the uterine cavity immediately after delivery of the placenta during cesarean delivery. The intrauterine device was fixed in place at the fundus using an absorbable suture. Patients were followed up at six weeks, then annually for three years.

Results:  Expulsion of the intrauterine device was not reported by any of the participants. The most-reported complaints in the first twelve months of intrauterine device placement were abdominal pain, abnormal vaginal discharge, and ‎heavy menstrual blood loss, however, none were statically significant (P= 0.256). After the first year, there was a significant reduction in the ‎frequency of complaints (P= 0.002).  Only 7.33% (95% CI: 6.92–7.75%) of the patient requested intrauterine device removal within the three years. The main reason was to plan a new pregnancy followed by recurrent infection associated with uncontrolled diabetes ‎mellitus. Diabetes was ‎a significant predictor for immediate post-partum intrauterine device removal, P= 0.049.

Conclusion: The intrauterine device placement during cesarean delivery with suture fixation is a safe procedure with a zero-expulsion rate and is an effective reversible long-term contraceptive method.

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Mon Nov 29 2021
Journal Name
Iraqi Journal Of Science
Histological study of the Isotretinoin drug effect on the intrauterine prenatal development in the pregnant mice
...Show More Authors

The isotretinoin drug is 13-cis-retinoic acid, is the treatment of severe acne and some skin cancers and used for dermatological conditions, this study was designed to detect the toxic role of the isotretinoin on the intrauterine development after implantation in albino mice during pregnancy. There are very little studies which indicating the side-effect of this drug on intra-uterine growth, so in the present research we tried to study the toxic effect of isotretinoin on the endometrial changes of uterus during the 2nd. and 3rd. trimester of gestation in pregnant mice after treatment with single chronic dose of the Isotretinoin drug (20 mg/B.wt) from first day of gestation until 21 days the last day of gestation.
The present study exa

... Show More
View Publication Preview PDF
Publication Date
Tue Jan 01 2019
Journal Name
Journal Of Human Sport And Exercise - 2019 - Spring Conferences Of Sports Science
The use of the electrical stimulation device for the muscles in the limit determines the elbow joint during the lifting of the disabled weightlifting players
...Show More Authors

View Publication
Scopus (1)
Scopus Clarivate Crossref
Publication Date
Sun Apr 02 2017
Journal Name
Journal Of The Faculty Of Medicine Baghdad
The correlation between serum levels of soluble platelet -selectin in preeclampsia with & without intrauterine growth retardation versus normal pregnancy
...Show More Authors

Background: preeclampsia is characterized by endothelial dysfunction with vasoconstriction due to cell adhesion molecules or mediators released by defective placentation. Soluble platelet selectin, one of the cell adhesion molecules, is elevated in many inflammatory conditions including preeclampsia.
Objective: To investigate if soluble platelet-selectin levels can be used as a marker for adverse outcomes in pregnancy complicated with sever preeclampsia
Patients and methods:This study involved 115 pregnant women in their third trimester of pregnancy; divided into Group A: involves 25 pregnant women with preeclampsia complicated by intrauterine growth restriction.Group B: involves 35 pregnant women with preeclampsia without intraute

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sun Oct 02 2005
Journal Name
Journal Of The Faculty Of Medicine Baghdad
immediate results of balloon angioplasty for native coarctation of the aorta
...Show More Authors

Background:

View Publication Preview PDF
Crossref
Publication Date
Tue May 07 2019
Journal Name
Acm Journal On Emerging Technologies In Computing Systems
Neuromemrisitive Architecture of HTM with On-Device Learning and Neurogenesis
...Show More Authors

Hierarchical temporal memory (HTM) is a biomimetic sequence memory algorithm that holds promise for invariant representations of spatial and spatio-temporal inputs. This article presents a comprehensive neuromemristive crossbar architecture for the spatial pooler (SP) and the sparse distributed representation classifier, which are fundamental to the algorithm. There are several unique features in the proposed architecture that tightly link with the HTM algorithm. A memristor that is suitable for emulating the HTM synapses is identified and a new Z-window function is proposed. The architecture exploits the concept of synthetic synapses to enable potential synapses in the HTM. The crossbar for the SP avoids dark spots caused by unutil

... Show More
View Publication
Scopus (12)
Crossref (12)
Scopus Clarivate Crossref
Publication Date
Sat Apr 30 2022
Journal Name
Sport Tk-revista Euroamericana De Ciencias Del Deporte
Effect of exercises on the VertiMax device on the endurance of under 16-years of age discus throwers
...Show More Authors

The primary aim of the present study was to prepare a set of exercises on the multi-resistor VertiMax device and to identify the effect of these exercises on the development of the endurance of discus throwers under 16 years old. The design of the present study was experimental. Participants were selected using purposive sampling method. A total of 5 discuss players constituted the sample of the study. The authors found a significant improvement in the levels of endurance and performance as a result of the training on the VertiMax device. Therefore, it is recommendable to use exercises on the VertiMax device to improve the endurance and performance of under 16-years of age discus throwers.

View Publication
Crossref
Publication Date
Wed Jun 30 2010
Journal Name
Al-kindy College Medical Journal
Electron Microscopic Study of the Effects of Preeclampsia on the Placental Endothelial Cells Ultra Structures during Pregnancy
...Show More Authors

Background: Preeclampsia occurs in 3-5% of
pregnancies and is a major cause (12-20 %) of
maternal mortality in developed countries. It is the
leading cause of preterm birth and intra-uterine
growth restrictions (IUGR).
Objective: The study was designed to determine and
demonstrate the ultra structural changes of
endothelial cells in placenta of women suffering from
hypertensive disease.
Patients & Methods: Placental samples were
obtained from two groups of pregnant women
groups (preeclamptic and normal pregnant women).
The specimens were fixed in 2.5% gluteraldehyde
and preceded for electron microscopic examination.
Results: Placenta of women with preeclampsia has
shown marked degenerative

... Show More
View Publication Preview PDF
Publication Date
Wed Mar 10 2021
Journal Name
Baghdad Science Journal
The follow up of experimentally infected hamsters with Leishmania tropica immunized with different vaccines
...Show More Authors

Some parameters for advancement of Leishmania tropica infection were examined in three groups of golden hamsters, Group (1) inoculated with autoclaved killed Leishmania tropica , Group (2) inoculated with BCG vaccine alone while Group (3) Inoculated with mixed vaccine (autoclaved killed Leishmania with BCG). The follow up of experimentally infected animals with virulent isolation of Leishmania tropica was done for 90 days, the animals inoculated with mixed vaccine (autoclaved killed Leishmania with BCG) showed the minimum average in each of foot pad thickness (2.3 ± 0.05) mm after (60) days of infection, spleen enlargement (1.13±0.38) after (45) days of infection, spleen length (23.9±0.08) mm after (30) days of infection, liver weight(3.

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sun Jul 02 2006
Journal Name
Journal Of The Faculty Of Medicine Baghdad
assessment of skeletal maturation of Iraqi children during the years of sanctions
...Show More Authors

background:

View Publication Preview PDF
Crossref
Publication Date
Wed Apr 05 2017
Journal Name
Journal Of Agriculture And Veterinary Science
Tillage Appearance Device Test When Used Mold Board Plow Under Difference of a Variables Condition
...Show More Authors

Tillage appearance device is mechanical, electric-electronic design, getting Patent from the Central Organization for Standardization and Quality Control – Industrial Property Department - Ministry of Planning – The Republic of IRAQ under number Patent 3876 in 20 / 4 / 2014, calculates the number of clods per area by Tillage appearance device, This is done through the generation electrical impulses are sent to the controlled accurate calculates number clods required space and shows the result on the screen in order to see the tillage view per area. Three factor used in these experiment, first factor represents forward speed of tractor three levels (3.5, 4.5, and 5.5 km/h), second factor represent soil moisture content at two levels (14

... Show More