Preferred Language
Articles
/
jkmc-797
Safety profile of immediate post-partum intrauterine device insertion during caesarean delivery – a clinical trial with three years of follow up: Utility of Immediate Post Placental Insertion of Intrauterine Device During Cesarean Delivery
...Show More Authors

Background: Many countries recommend the use of long-acting reversible contraceptive intrauterine device immediately after cesarean delivery. The cesarean delivery rate in Iraqi public hospitals is 32.2% and may reach 85.8% in private hospitals. Immediate post-partum intrauterine device insertion at cesarean is rarely done in Iraq.

Objectives: To assess the safety and practicality of immediate post-partum intrauterine device insertion during cesarean delivery for family planning and pregnancy spacing in Iraqi women.

Subjects and Methods: A single arm clinical trial included 150 eligible women who attended Al-‎Elwiyah Maternity Teaching Hospital or Al Hayat Rahibat Hospital for term delivery. A copper intrauterine device was placed in the uterine cavity immediately after delivery of the placenta during cesarean delivery. The intrauterine device was fixed in place at the fundus using an absorbable suture. Patients were followed up at six weeks, then annually for three years.

Results:  Expulsion of the intrauterine device was not reported by any of the participants. The most-reported complaints in the first twelve months of intrauterine device placement were abdominal pain, abnormal vaginal discharge, and ‎heavy menstrual blood loss, however, none were statically significant (P= 0.256). After the first year, there was a significant reduction in the ‎frequency of complaints (P= 0.002).  Only 7.33% (95% CI: 6.92–7.75%) of the patient requested intrauterine device removal within the three years. The main reason was to plan a new pregnancy followed by recurrent infection associated with uncontrolled diabetes ‎mellitus. Diabetes was ‎a significant predictor for immediate post-partum intrauterine device removal, P= 0.049.

Conclusion: The intrauterine device placement during cesarean delivery with suture fixation is a safe procedure with a zero-expulsion rate and is an effective reversible long-term contraceptive method.

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Sun Jan 01 2023
Journal Name
8th Engineering And 2nd International Conference For College Of Engineering – University Of Baghdad: Coec8-2021 Proceedings
Serviceability performance of high-strength concrete flexural members with internally unbonded post-tensioning strands
...Show More Authors

View Publication
Crossref
Publication Date
Wed Jan 02 2013
Journal Name
Journal Of The Faculty Of Medicine Baghdad
Irrigtion of Gallbladder bed with bupivacaine for post- operative pain relief in laparoscopic cholecystectomy.
...Show More Authors

Background: Although pain after laparoscopic cholecystectomy is less intense than after open Cholecystectomy, some patients still experience considerable discomfort, and use of local anaesthetics irrigation is controversial.

Objectives :to evaluate the effect of intraperitoneal and port site instillation of local anaesthetics on pain relief in the first 6 hours postoperatively.

Patient and Method: Forty patients underwent elective laparoscopic cholecystectomy were included in this study and sample was divided into two equal groups. Group A received 20 ml of 0.9% normal saline instilled in the gallbladder bed, while group B received 20 ml of 0.25% bupivacaine instilled in

... Show More
View Publication Preview PDF
Crossref (2)
Crossref
Publication Date
Wed Sep 14 2016
Journal Name
Journal Of Baghdad College Of Dentistry
Assessment of Salivary Secretory Immunoglobulin A (sIg A) Level during Fixed Orthodontic Treatment
...Show More Authors

Background: The immune system of the oral cavity suffers alterations due to fixed orthodontic treatment which act as potent stimulus for oral secretory immunity. The aims of this study are to estimate the effect of fixed orthodontic appliance on the level of salivary sIgA at different time intervals, and to verify the gender difference. Materials and method: The patient's history, clinical examination, and fixed orthodontic appliances were placed for 30 Iraqi orthodontic adult patients had class II division 1 and/ or class I malocclusion (15 males and 15 females) aged 18-25 years old. The unstimulated whole saliva was collected from each sample immediately before wearing fixed appliance (control group T0 as base line), and after 2 weeks (T1

... Show More
View Publication Preview PDF
Crossref
Publication Date
Wed Apr 01 2009
Journal Name
Journal Of The Faculty Of Medicine Baghdad
The Effect of Body Mass Index of Patients with Post Myocardial Infarction Angina on the Heart Function
...Show More Authors

Background: Extreme obesity is recognized to be a risk factor for coronary heart disease. It is unclear whether overweight and normal weight also poses a risk.
Objective: The study aims to determine the effect of the body mass index on coronary arteries and left ventricular functions in patients with post myocardial infarction (MI) angina
Method: The study included 50 patients with the diagnosis of post MI angina consecutively admitted to the medical ward of Iraqi Center for Heart Disease. All patients underwent
coronary artery catheterization and Echocardiography for assessment of coronary artery and left ventricular functions 
Results: The results of the study showed that there is a significant diff

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sun Jan 04 2009
Journal Name
Journal Of The Faculty Of Medicine Baghdad
The Effect of Body Mass Index of Patients with Post Myocardial Infarction Angina on the Heart Function
...Show More Authors

Background: Extreme obesity is recognized to be a risk factor for coronary heart disease. It is unclear whether overweight and normal weight also poses a risk.
Objective: The study aims to determine the effect of the body mass index on coronary arteries and left ventricular functions in patients with post myocardial infarction (MI) angina
Method: The study included 50 patients with the diagnosis of post MI angina consecutively admitted to the medical ward of Iraqi Center for Heart Disease. All patients underwent
coronary artery catheterization and Echocardiography for assessment of coronary artery and left ventricular functions
Results: The results of the study showed that there is a significant difference

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sun Jan 01 2023
Journal Name
Aip Conference Proceedings
Fast lightweight encryption device based on LFSR technique for increasing the speed of LED performance
...Show More Authors

LED is an ultra-lightweight block cipher that is mainly used in devices with limited resources. Currently, the software and hardware structure of this cipher utilize a complex logic operation to generate a sequence of random numbers called round constant and this causes the algorithm to slow down and record low throughput. To improve the speed and throughput of the original algorithm, the Fast Lightweight Encryption Device (FLED) has been proposed in this paper. The key size of the currently existing LED algorithm is in 64-bit & 128-bit but this article focused mainly on the 64-bit key (block size=64-bit). In the proposed FLED design, complex operations have been replaced by LFSR left feedback technology to make the algorithm perform more e

... Show More
View Publication
Scopus (1)
Crossref (1)
Scopus Crossref
Publication Date
Thu Feb 16 2023
Journal Name
Iraqi Journal Of Pharmaceutical Sciences ( P-issn 1683 - 3597 E-issn 2521 - 3512)
Combination of FDM 3D Printing and Compressed Tablet for Preparation of Baclofen as Gastro-Floating Drug Delivery System (Conference Paper )#
...Show More Authors

This study aimed to develop an oral drug delivery system for gastro-retentive sustained drug release of baclofen by using a 3D printed capsular device since baclofen has a short half-life of 2.5 to 4 hours and has a narrow absorption window. Firstly sustained-release tablets of baclofen were formulated through the hot-melt extrusion of various thermoplastic polymers and direct compression of the extrudate, then a capsular device was designed and 3D printed to contain two air pockets to enable floating of the device and has four windows for drug release.

3D printing of the capsular device was done by an FDM printer using biodegradable PLA filament, and the sustained release tablets were inserted into the device to allow the medici

... Show More
View Publication Preview PDF
Crossref (2)
Crossref
Publication Date
Sat Jun 28 2014
Journal Name
Iraqi Postgraduate Medical Journal
Comparism Between Transvaginal Cervical Length Measurement and Digital Examination in Prediction of Imminent preterm Delivery
...Show More Authors

BACKGROUND: Preterm labour is a major cause of perinatal morbidity and mortality, so it is important to predict preterm delivery using the clinical examination of the cervix and uterine contraction frequency. New markers for the prediction of preterm birth have been developed such as transvaginal ultrasound measurement of cervical length as this method is widely available. OBJECTIVE: To determine, whether transvaginal cervical length measurement predicts imminent preterm delivery better than digital cervical length measurement in women presented with preterm labour and intact membranes. PATIENTS AND METHODS: Two hundred women presented with preterm labour between 24 and 36+6 weeks of gestation were included in this study. All women subjecte

... Show More
View Publication
Publication Date
Sun Dec 27 2020
Journal Name
Iraqi Journal Of Pharmaceutical Sciences ( P-issn 1683 - 3597 E-issn 2521 - 3512)
Evaluation the Risk Factors that are Associated with Osteoporosis in Post Kidney Transplantation in a Sample of Iraqi Patients
...Show More Authors

Renal transplantation is a principal treatment option for end-stage kidney failure. Bone loss and fracture are serious complication of kidney transplantation, associated with morbidity and mortality. The pathogenesis of post transplantation bone loss is multifactorial and complex

View Publication Preview PDF
Scopus (3)
Scopus Crossref
Publication Date
Sun Sep 03 2023
Journal Name
Al-mansour Journal
Biometrics Systems Challenges in a Post-COVID-19 Pandemic World: A review
...Show More Authors

One of the most serious health disasters in recent memory is the COVID-19 epidemic. Several restriction rules have been forced to reduce the virus spreading. Masks that are properly fitted can help prevent the virus from spreading from the person wearing the mask to others. Masks alone will not protect against COVID-19; they must be used in conjunction with physical separation and avoidance of direct contact. The fast spread of this disease, as well as the growing usage of prevention methods, underscore the critical need for a shift in biometrics-based authentication schemes. Biometrics systems are affected differently depending on whether are used as one of the preventive techniques based on COVID-19 pandemic rules. This study provides an

... Show More
View Publication Preview PDF