Background: Acute cholecystitis is common surgical
problem, which was treated previously by conservative
treatment .Later early open has been introduced as an
alternative to interval for treatment of acute cholecystitis.
Early open was found to be a safe, successful with
comparable postoperative complication rate. With the
advent of laparoscopy laparoscopic have been used for
chronic cholecystitis and became the first line of
treatment. New reports have shown that laparoscopic can
be used as an alternative to open for surgical treatment of
acute cholecystitis.
Objectives: to compare the success, safety of early
laparoscopic versus early open as a primary treatment of
acute cholecystitis.
Methods: out of 68 patients were treated for clinical
acute cholecystitis between January 2002 and February
2004 in the department of surgery, at Al – Kindy teaching
hospital. A total of 62 patients underwent early for acute
cholecystitis as soon as possible after diagnosis. The
preferred preoperative imaging technique was ultrasound.
30 (48.3%) of the operations were attempted
laparoscopically, whereas the remaining 32 patients
(51.7%) underwent initial open .
Results: The mean operative time for the open cases
was 75 minutes versus 60 minutes for the laparoscopic
group. There was no perioperative mortality in either
group. The incidence of conversion to open was 10% (3
patients). Surgical complications related to laparoscopic
and open occurred in 2 (6.6%) and 3 (9.3%) cases,
respectively. There was no difference between the open
and laparoscopic groups in regard to the major
postoperative complications.
Conclusion: The current study shows that early
(whether performed by open or laparoscopically) is a
safe and effective treatment for acute cholecystitis. Low
conversion rates can be maintained with strict guidelines
for appropriate patient selection, adequate experience,
and proper laparoscopic technique.
Solar hydrogen line emission has been observed at the frequency of 1.42 GHz (21 cm wavelength) with 3m radio telescope installed inside the University of Baghdad campus. Several measurements related to the sun have been conducted and computed from the radio telescope spectrometer. These measurements cover the solar brightness temperature, antenna temperature, solar radio flux, and the antenna gain of the radio telescope. The results demonstrate that the maximum antenna temperature, solar brightness temperature, and solar flux density are found to be 970 K, 49600K, and 70 SFU respectively. These results show perfect correlation with recent published studies.
In this paper, Touchard polynomials (TPs) are presented for solving Linear Volterra integral equations of the second kind (LVIEs-2k) and the first kind (LVIEs-1k) besides, the singular kernel type of this equation. Illustrative examples show the efficiency of the presented method, and the approximate numerical (AN) solutions are compared with one another method in some examples. All calculations and graphs are performed by program MATLAB2018b.
In recent years, the number of applications utilizing mobile wireless sensor networks (WSNs) has increased, with the intent of localization for the purposes of monitoring and obtaining data from hazardous areas. Location of the event is very critical in WSN, as sensing data is almost meaningless without the location information. In this paper, two Monte Carlo based localization schemes termed MCL and MSL* are studied. MCL obtains its location through anchor nodes whereas MSL* uses both anchor nodes and normal nodes. The use of normal nodes would increase accuracy and reduce dependency on anchor nodes, but increases communication costs. For this reason, we introduce a new approach called low communication cost schemes to reduce communication
... Show MoreBackground: Surface treatment of machined dental zirconia for enhancement of the adhesion to resin cement, using Er,Cr:YSGG Laser. Materials and Methods: Total number of 42 zirconia disc specimens (9 mm diameter, and 2 mm height) was sintered according to the manufacturer instruction. They are divided into six groups, each group of seven samples. Laser groups (Experiment parameters) were depend on laser total irradiation time, pulse duration, and power. Group (A): 20 sec., 60 µs pulse duration. Group (B): 30 sec., 60 µs pulse duration. Group (C): 40 sec., 60 µs pulse duration. Group (D): 20 sec., 700 µs pulse duration. Group (E): 30 sec., 700 µs pulse duration, with different powers used (1, 1
... Show MoreIn this paper, an approach for object tracking that is inspired from human oculomotor system is proposed and verified experimentally. The developed approach divided into two phases, fast tracking or saccadic phase and smooth pursuit phase. In the first phase, the field of the view is segmented into four regions that are analogue to retinal periphery in the oculomotor system. When the object of interest is entering these regions, the developed vision system responds by changing the values of the pan and tilt angles to allow the object lies in the fovea area and then the second phase will activate. A fuzzy logic method is implemented in the saccadic phase as an intelligent decision maker to select the values of the pan and tilt angle based
... Show MoreThe aim of this research was to evaluate the level of ball control in basketball. There was a great weakness in ball control that affected the mastery of many skills that affect the success of the team. The researcher also found a lack in training programs concerning ball control. The researchers used (9) special tests for ball control out of (41) test applied on young basketball players were (86). The researchers concluded that: 1. Criteria were set for test results of ball control. 2. A level of criteria was set for test results of ball control.