Background: Environmental chemicals are thought to
adversely affect human reproductive function.
Objective : To estimate the concentration of cadmium(Cd)
, lead ( Pb ) and Zinc ( Zn ) in serum and seminal plasma
among infertile men .
Methods: A sample of 70 infertile men was investigated.
The relationship of trace elements concentration in serum and
seminal plasma was studied in relation to sperm density,
motility and sperm count.
Results: Except for Zinc the concentration of (Pb) and (Cd)
were generally higher in serum than in seminal plasma. The
mean concentration of (Zn) in seminal plasma was more than
25 times higher than in serum There were no statistical
significant differences observed in the serum and seminal
plasma levels of trace elements among the normospermic ,
oligospermic and azoospermic.
Conclusion: It seems that no significant relationship
between these trace elements and the clinical classification of
the infertile men was noted. Without considering
environmental conditions of life and work, way of nutrition
smoking and other possible factors, this study does not
present great value.
A new simple sensitive and selective spectrophotometric method has been developed for the analysis of vanadium(V) in three randomly chosen samples from river water at different locations by continuous flow injection analysis. The method based on the oxidation of pyrogallol by vanadium(V) in acidic solution to form color species and the same species was determined using homemade Ayah 6SX1-T-2D solar cell analyser . Chemical and physical parameters were investigated using the high intensity of snow white light emitted diode as a source. The linear dynamic range for the instrument response versus vanadium(V) concentration was 1-200 mg.L-1 with correlation coefficient r = 0.9920. The limit of detection (S/N=3) was 70 ng/ sample from the step
... Show MoreA newly developed FIA-merging zones spectrophotometric system, the method is rapid, accurate and sensitive for metformin hydrochloride determination through the oxidation of 1- naphthol by sodium hypochlorite and coupling with metformin.HCl in the presence of sodium hydroxide to form a blue soluble ion pair and this product was determined using homemade CFIA-Merging zones techniques , at 580 nm. Data treatment shows that linear range is (0.5-35) µg/ ml. The optimization conditions for various chemical and physical conditions of [MTF- NaOCl-α-naphthol-NaOH] system were investigated. The LOD was 0.01µg / ml and LOQ 0.1µg/ml from the lowest concentration of the calibration graph with r2% 99.18 and RSD% did
... Show MoreNew mode for the on-line determination of oxonium ion in different strong acids using CFIA via the use of homemade linear array Ayah 5Sx4-ST- 5D solar CFI analyser
A new simple sensitive and selective spectrophotometric method has been
developed for the analysis of vanadium(V) in three randomly chosen samples from
river water at different locations by continuous flow injection analysis. The method
based on the oxidation of pyrogallol by vanadium(V) in acidic solution to form color
species and the same species was determined using homemade Ayah 6SX1-T-2D
solar cell analyser . Chemical and physical parameters were investigated using the
high intensity of snow white light emitted diode as a source. The linear dynamic
range for the instrument response versus vanadium(V) concentration was 1-200
mg.L-1 with correlation coefficient r = 0.9920. The limit of detection (S/N=3) was 70<
This piece of research work aims to study one of the most difficult reaction and determination due to continuous and rapid variation of reaction products and the reactants. As molybdenum (VI) aid in the decomposition of hydrogen peroxide in alkaline medium of ammomia, thus means a continuous liberation of oxygen which cuases and in a continuous manner a distraction in the measurement process. On this basis pyrogallol was used to absorbe all liberated oxygen and the result is an a clean undisturbed signals. Molybdenum (VI) was determined in the range of 4-100 ?g.ml-1 with percentage linearity of 99.8% or (4-300 ?g.ml-1 with 94.4%) while L.O.D. was 3.5 ?g.ml-1. Interferring ions (cations and anions) were studied and their main effect was red
... Show MoreA newly developed analytical method characterized by its speed and sensitivity for
the determination of cadmium (II) in aqueous solution in three randomly chosen
samples from river water at different locations via turbidimetric measurement by
Ayah 6SX1-T-2D Solar - CFI analyser. The method is based on the formation of
yellowish white precipitate for the complex Cd3[Fe(CN)6]2 by direct reaction of the
cadmium (II) with potassium hexacyano ferrate (III) in aqueous medium. Turbidity
was measured via the reflection of incident light that collides on the surfaces
precipitated particles at 0-180o. Chemical and physical parameters were investigated.
Linear dynamic of cadmium (II) is ranged from 0.05-12 mmol.L-1, with cor
One of the most common procedures in oral surgery is the removal of impacted mandibular third molars, often followed by pain, swelling, alveolitis, and trismus. Purpose. To compare the outcomes of the intrasocket application of 1% hyaluronic acid oral gel (HA) and advanced platelet-rich fibrin (A-PRF) on the expected postoperative complications, pain, swelling, and trismus follow the surgical extraction of the impacted mandibular third molar. Material and Methods. A randomized controlled trial was conducted at the Oral and Maxillofacial Surgery Unit, Dental Teaching Hospital. Healthy patients who required surgical removal of the impacted mandibular third molar were divided randomly into three groups. The extraction site of the group
... Show MoreThe aim of this study was to measure the effectiveness of a proposed program to develop the creative abilities of the students of Tabuk University and its impact on the creative output of the NEOM project. The sample of the study consisted of (50) university students divided into two groups: an experimental group of 25 students who receive the proposed training program, and control group of (25) students.
To achieve these objectives, the researcher designed and developed tools to collect the required data, which were verified their validity and reliability.
The descriptive statistics of mean, standard deviations, correlation coefficient, T test for the associated sample were used in the analysis of the results of th
... Show More