Background: The liver is one of the most common organs
injured after blunt abdominal trauma. The control of severe
hemorrhage remains a problem.
Methods: One-hundred thirty-eight patients diagnosed as
liver injury between 09/2003 and 08/2006 had been evaluated
prospectively in Al- Kindy Teaching Hospital.
A distinction was made between hemodynamically stable and
unstable patients. Different modalities of surgical procedures
were done concentrating on perihepatic gauze packing.
Results: (60 out of 138) patients included in the study were
clinically evaluated as hemodynamically stable. The average
abbreviated injury severity score (ISS) was 25. Twenty
patients underwent abdominal surgery. In 12 of them
additional liver treatment was performed. The mortality was
three, all were non-liver related.
Seventy eight patients were considered to be
hemodynamically unstable, and had an average ISS of 38. All
of them needed abdominal surgery.
Gauze packing was used as initial therapy for bleeding
control from injured liver in 34 patients of both
hemodynamically stable and unstable groups with a mortality
of 11 patients (32.7%).
Conclusion: perihepatic gauze packing is considered as a life
saving and a quick method for controlling ongoing
hemorrhage in the treatment of liver injuries before
undertaking definitive repair under controlled conditions
A fracture is a damage to bone tissue that causes damage to the tissue surrounding the bone and may penetrate the skin. Subjects and methods: the present study included (80) fractured Iraqi patients (and 40) patients with DM2 and (40) without DM2 and compared them with (40) healthy control. Patients and control are matched in age. This study showed a significant increase in retinol-binding protein 4 (RBP4) and a considerable decrease in Vit .A GPT and GOT in fracture patients with and without DM2. In addition, there was a significant negative correlation between RBP4 with (GPT and GOT) in fracture patients with DM2 and a significant positive correlation between RBP4 with (GPT and GOT) in fracture patients without DM2.
... Show MoreBackground. Dental implantation has become a standard procedure with high success rates, relying on achieving osseointegration between the implant surface and surrounding bone tissue. Polyether ether ketone (PEEK) is a promising alternative to traditional dental implant materials like titanium, but its osseointegration capabilities are limited due to its hydrophobic nature and reduced surface roughness. Objective. The aim of the study is to increase the surface roughness and hydrophilicity of PEEK by treating the surface with piranha solution and then coating the surface with epigallocatechin-3-gallate (EGCG) by electrospraying technique. Materials and Methods. The study includes four groups intended to investigate the effect of pir
... Show MoreThis research studies the effect of particle packing density on sintering TiO2 microstructure. Sintering experiment was conducted on compacts involving of monodisperse spherical TiO2 particles. The experimental results are modeled using L2-Regression technique in studing the effect of two theoretical values of 55% and 69% of initial packing densities. The mathematical simulation shows that the lower values of density compacts sintered fast to theoretical density and this reflects that particle packing density improved densification rate because of the competing influence of grain growth at higher values of densities.
Clopidogrel is a prodrug that must be transformed into an active metabolite by hepatic cytochrome P450 (CYP) isoenzymes to prevent platelet clotting. Polymorphisms of the CYP2C19 gene can cause a reduction or complete loss of CYP2C19 enzyme activity resulting in inhibiting clopidogrel metabolism, effectiveness and increase stroke recurrence risk in ischemic stroke patients. This study aims to investigate the correlation between genetic polymorphisms in CYP2C19*2 and*3 and recurrent risk in patients with ischemic stroke taking clopidogrel 75mg in Kurdistan region –Iraq. This retrospective case-control study was carried out at Kurdistan, Erbil, Medicina medical center, and Rizgary general hospital from January 2021 to
... Show MoreThis research focuses on improvement of the corrosion behaviour of commercial pure titanium (Ti) grade II when exposed to Hank’s solution through different surface treatments. The disc shape of titanium samples were constructed to be divided according to their surface treatment. The first experimental group the Ti sample was exposed to computer numerical control (CNC) fiber laser machine. Whereas, the other experimental group the Ti sample was only coated with Polyetherketon keton (PEKK) by using carbon dioxide (CO2) laser technique while the last experimental group the Ti sample was treated with CNC fiber laser followed by PEKK coating by using CO2 laser technique. All were compared with the untreated control group. The electrochemical a
... Show More