Preferred Language
Articles
/
jkmc-735
Lipid Profile and Menopausal Status
...Show More Authors

Background: Dyslipidemia is a major cause of
cardiovascular disease, which in turn, is the most
common cause of female morbidity and mortality.
Postmenopausal women (natural and surgical) are at
higher risk of developing cardiovascular disease,
especially coronary artery atherosclerosis.
Objective: To observe the relationship between blood
lipids: total cholesterol (TC), high density lipoproteincholesterol (HDL-C), low density lipoproteincholesterol (LDL-C), triglycerides (TGs), and very low
density lipoprotein- cholesterol (VLDL-C), LDL-C/
HDL-C ratio (atherogenic index) and menopausal
status, and to determine the co-factors that may explain
this relationship
Methods: A prospective, cross-sectional study, which
includes 279 women, age range from 35-55 years
agreed to participate in this study. They were divided
into 4 groups according to their menopausal status.
These were pre-, peri post- natural and surgical postmenopausal. Data were collected from participants in a
pre-coded questionnaire and an overnight fasting blood
sample was collected for biochemical analysis.
Results: Postmenopausal women had higher levels of
lipids than pre or peri-menopausal. TC concentration
and LDL-cholesterol levels were higher in natural and
surgical menopause than in pre and pri-menopausal
women (p<0.01 and p<0.05 respectively). While
LDL/HDL-C ratio (atherogenic index) were higher in
the surgical postmenopausal women than in premenopausal group (p<0.05). No significant inter-group
differences were found in HDL-C. Triglycerides, and
VLDL levels were higher in surgical menopause group
than in both pre- and peri-menopause groups (p<0.05).
No significant differences were demonstrated in pre-,
peri-, and natural menopausal women with regard to
triglyceride and VLDL levels and LDL/HDL-C ratio.
Conclusion : Dyslipidemia is more frequent among
women with natural and surgical menopause groups
than in the other groups. This makes those women
more susceptible to CVD. Certain co factors appear to
have direct associations with lipid levels in each group
and those were discussed.

View Publication Preview PDF
Quick Preview PDF
Publication Date
Wed Feb 07 2024
Journal Name
Egyptian Journal Of Chemistry
Spectrophotometric Estimation of Methyldopa Drug in pure and pharmaceutical formulations
...Show More Authors

View Publication Preview PDF
Scopus (1)
Crossref (1)
Scopus Clarivate Crossref
Publication Date
Sun Jan 27 2019
Journal Name
Journal Of The College Of Education For Women
Interpretation, interpretation of opinion.. Its history and limits of use
...Show More Authors

This research, the author deals with a number of topics, including: What is interpretation?, the difference between exegesis and I interpretation of the Quran, the meaning of interpretation in the term, and the meaning of interpretation in the terminology of the people of interpretation, It deals with then, he demonstrates the interpretation and reasoning meanings of language, and the need of Muslims to interpret the Quran, and limitations of the use of interpretation and exegesis, On the interpretation of opinion and when it began, and the need of Muslims to explain, Finally he discusses the ways of interpretation, and the conditions to be provided in the interpreter.

View Publication Preview PDF
Publication Date
Sun Feb 03 2019
Journal Name
Journal Of The College Of Education For Women
Shifting Sand of English in Iraq language Policy and Planning
...Show More Authors

Shifting Sand of English in Iraq language Policy and Planning

View Publication Preview PDF
Publication Date
Mon Jul 10 2023
Journal Name
Journal Of Engineering
Analysis and Optimum Design of Self Supporting Steel Communication Tower
...Show More Authors

The present study deals with the optimum design of self supporting steel communication towers. A special technique is used to represent the tower as an equivalent hollow tapered beam with variable cross section. Then this method is employed to find the best layout of the tower among prespecified configurations. The formulation of the problem is applied to four types of tower layout
with K and X brace, with equal and unequal panels. The objective function is the total weight of the tower. The variables are the base and the top dimensions, the number of panels for the tower and member's cross section areas. The formulations of design constraints are based on the requirements of EIA and ANSI codes for allowable stresses in the members

... Show More
View Publication Preview PDF
Crossref
Publication Date
Thu Mar 01 2018
Journal Name
Journal Of Engineering
Permeability Estimation by Using the Modified and Conventional FZI Methods
...Show More Authors

There many methods for estimation of permeability. In this Paper, permeability has been estimated by two methods. The conventional and modified methods are used to calculate flow zone indicator (FZI). The hydraulic flow unit (HU) was identified by FZI technique. This technique is effective in predicting the permeability in un-cored intervals/wells. HU is related with FZI and rock quality index (RQI). All available cores from 7 wells (Su -4, Su -5, Su -7, Su -8, Su -9, Su -12, and Su -14) were used to be database for HU classification. The plot of probability cumulative of FZI is used. The plot of core-derived probability FZI for both modified and conventional method which indicates 4 Hu (A, B, C and D) for Nahr Umr forma

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sun Jun 02 2019
Journal Name
International Journal Of Drug Delivery Technology
Kinetic-spectrophotometric estimation of tetracycline in bulk and pharmaceutical forms
...Show More Authors

Simple and sensitive spectrophotometric method is described based on the coupling reaction of tetracycline hydrochloride (TC. HCl) with diazotized 4-aminopyridine in bulk and pharmaceutical forms. Colored azo dye formed during this reaction is measured at 433 nm as a function of time. Factors affecting the reaction yield were studied and the conditions were optimized. The kinetic study involves initial rate and fixed time (10 minutes) procedures for constructing the calibration graphs to determine the concentration of (TC. HCl). The graphs were linear for both methods in concentration range of 10.0 to 100.0 μg.mL-1. The recommended procedure was applied successfully in the determination of (TC. HCl) in its commercial formulations.

Scopus (3)
Scopus
Publication Date
Sun Feb 10 2019
Journal Name
Journal Of The College Of Education For Women
Effect Repetition of Anticyclone and on thermal characteristic in Iraq
...Show More Authors

Anticyclone of synoptic studies that influence weather and climate of Iraq, The aim of
the study is to clarify the effect variation of repetition of Anticyclone and effect on thermal
characteristic in Iraq were pressure level has been analyzed (1000) millibars and that because
of pressure level is the closet to the earth surface and the clarity of climatic phenomenon
based on a systematic analysis of synoptic seeking maps and observation and (12:00)
according to timing GMT for five climatic stations which is (Mosul, Kirkuk, Baghdad, Rutba,
and Basra) and so far three consecutive climatic cycles which is first climatic cycle for period
(1986-1976). and second climatic cycle for period (1997-1987) and third climatic cy

... Show More
View Publication Preview PDF
Publication Date
Tue Aug 15 2023
Journal Name
Al-academy
Digital modeling and its technical variables in contemporary interior design
...Show More Authors

The current research sheds light on an important aspect of the great and rapid development in the field of science and technology and modern manufacturing methods as a result of the scientific revolution resulting from the accelerated cognitive development, which prompted designers in general and interior design in particular to exploit and invest in digital technology and the development of digital control in the process of designing the industrial product for the purpose of creativity and innovation through these digital programs Digital models achieve the requirements and desires of the interior designer according to the creative skill using modern software with high efficiency And extreme accuracy that is consistent with the requirem

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sun Jan 01 2017
Journal Name
Journal Of Engineering
Detection and Diagnosis of Induction Motor Faults by Intelligent Techniques
...Show More Authors

This paper presents a complete design and implementation of a monitoring system for the operation of the three-phase induction motors. This system is built using a personal computer and  two types of sensors (current, vibration) to detect some of the mechanical faults that may occur in the motor. The study and examination of several types of faults including (ball bearing and shaft misalignment faults) have been done through the extraction of fault data by using fast Fourier transform (FFT) technique. Results showed that the motor current signature analysis (MCSA) technique, and measurement of vibration technique have high possibility in the detection and diagnosis of most mechanical faults with high accuracy. Subsequently, diagnosi

... Show More
View Publication Preview PDF
Publication Date
Sun May 01 2016
Journal Name
Journal Of Engineering
Assessing Asphalt and Concrete Pavement Surface Texture in the Field
...Show More Authors

The incorporation of safety characteristics into the traditional pavement structural design or in the functional evaluation of pavement condition has not been established yet. The design has focused on the structural capacity of the roadway so that the pavement can withstand specific level of repetitive loading over the design life. On the other hand, the surface texture condition was neither included in the AASHTO design procedure nor in the present serviceability index measurements.

The pavement surface course should provide adequate levels of friction and ride quality and maintain low levels of noise and roughness. Many transportation departments perform routine skid resistant testing, the type of equipment us

... Show More
View Publication Preview PDF