Background: Blood vessels injury is one of the most
common causes of medical emergencies that admitted to
hospitals and at the same time it regarded as one of the
most important causes of death. They may represent less
than 15% of all injuries; they deserve special attention
because of their severe complications.
Objective: The aim of the present study is to assess
anatomically the injures of major arteries and veins in the
lower limb with their management.
Methods: The present study extended from April 2006 to
February 2007, in which 65 patients with lower limb
vascular injury were examined in Emergency Department
and Forensic Medicine Department of Tikrit Teaching
Hospital in Salah-Aldin governorate. Diagnosis was made
by clinical diagnosis alone, or in combination with
angiography. Some surgical interferences as vascular
repair was carried out, but if not possible the interposition
graft was used by great saphenous vein for vascular
reconstruction.
Results: The total cases were 65 patients (49 males and 16
females), ranging from 16 years to 67 years with a mean
age of 41.5±6.4 years. Penetrating trauma was the main
cause of injury for 52 patients. Seventeen cases had
bilateral limbs vascular injuries. Arterial injuries were most
common in the femoral arteries, followed by the tibial and
finally the popliteal arteries. Vascular repair were
performed in 16 cases, while in 11 cases great saphenous
vein interposition graft were done. There were 17 cases
associated with venous injury, of which 11 cases had
surgical vascular repair, and 6 had vein graft interposition.
There were concomitant femur fractures in 2 cases, fibula
fractured in 3, tibia fractured in 1 and the foot bones
fractured in 3.
Conclusion: Lower limb vascular injured patient should be
transferred to vascular surgery centers as soon as possible.
After first aid management, anticoagulant treatment may be
started post operatively to prevent the propagation of the
thrombosis. Early fasciotomy is done if there is any
suspicion of occurrence of compartment syndrome.
The adsorption behavior of Bismarck brown (BB) dye from aqueous solutions onto graphene oxide GO and graphene oxide-g-poly (n-butyl methacrylate-co-methacrylic acid) GO-g-pBCM as adsorbents was investigated. The prepared GO and GO-g-pBCM were characterized by Fourier transform infrared spectroscopy FTIR, which confirmed the compositions of the prepared adsorbents. Adsorption of BB dye onto GO and GO-g-pBCM was explored in a series of batch experiments under various conditions. The data were examined utilizing Langmuir and Freundlich isotherms. The Langmuir isotherm was seen as increasingly reasonable from the experimental information of dye on formulating adsorbents. Kinetic investigations showed that the experimental data were fitted ve
... Show MoreHerein, date palm (Phoenix dactylifera) bunch (DPB) waste was transformed into activated carbon (DPAC) adsorbent by using microwaveinduced ZnCl2 activation for 15 min at a power of 600 W. Several analytical methods were used to explain the physicochemical parameters of DPBAC including XRD, pHpzc, BET, SEM–EDX, and FTIR. Afterwards, the adsorptive performance of DPBAC was thoroughly investigated for the removal of two structurally different organic dyes namely methyl violet (MV) and fuchsin basic (FB). The key adsorption parameters, including the dose of DPBAC (A: 0.02–0.06 g), the solution pH (B: 4–10), and the contact time (C: 2–20 min) were statistically optimized using the Box-Behnken design with response surface methodology (RSM
... Show MoreIn this work, electrochemical process was presented to polymerized eugenol on Gr.2 and Gr.5 titanium alloys before and after treated by Micro Arc Oxidation (MAO), where Gr.2 is commercial pure titanium and Gr.5 is Ti-6Al-4V dental alloys. The deposited layers were characterized by scanning electron microscopy (SEM), energy-dispersive X-ray spectroscopy (EDS), X-ray diffraction (XRD), and Fourier transform infrared spectroscopy (FTIR). The adhesion strength of polymeric thin-film was estimation by using pull-off adhesion test and the result was the adhesion strength of PE was (1.23 MPa) on Gr.2 before MAO and increase to (1.98 MPa) on Gr.2 after MAO treatment. The corrosion behavior of Gr.2 and Gr.5 alloy in artificial saliva environment at
... Show MoreA new Schiff base (HL2) ligand (4‐{2‐[(2‐hydroxy‐benzylidene)‐amino]‐ethyl}‐benzene‐1,2‐diol) has been synthesized by condensing of 4‐(2‐amino‐ethyl)‐benzene‐1,2‐diol and 2‐hydroxy‐benzaldehyde. In turn, its transition metal complexes were prepared, having the following general formulas: Ni(L2)2, Pd(L2)2, and Pt(L2)22Cl. The prepared ligand and its metal complexes Ni(II), Pd(II), and Pt(IV) have been characterized by Fourier transform infrared (FTIR) spectra, proton nuclear magnetic resonance (1H‐NMR
The A.C conductivity of three samples of lanthanide oxide : zinc oxide (La2O3)1-x(ZnO)x pellets with different zinc oxide content which were sintered 1273 K temperatures were studied using LRC meters in the frequency range of 50–106 Hz at temperature of 30 °C. The a.c conductivity, was analyzed depending of the universal power law proposed by Jonsher,. The slope of the relation between logarithm of a.c conductivity and angular frequency represent the s value were in the range (0.44-0.77) which found to increase by increasing of zinc oxide content which coincided with the small po