Background: Fiber-optic endoscopy is an important
investigation of the large intestine, whether or not the
radiologist (barium enema) has discovered a lesion in
the bowel. Colonoscopy affords a unique opportunity
to direct visualization of entire colonic mucosa. At
the same time, the physician can obtain biopsy specimens, remove polyps, and decompress volvuli.
Most experienced endoscopists and well prepared
patients can reach the cecum in over 90% of patients.
If colonoscopy is properly performed, it has a low
risk of complications, such as perforation and bleeding.
Methods: A total of 70 consecutive patients admitted
to Endoscopy department at Al-Kindy Teaching hospital from September- 2008 to July-2009. Bowel
preparation was achieved with Polyethylene glycol
lavage solution and 165 cm Pentax colonoscope
EC_3385FK 4.2 was used in all cases. All patients
were not sedated or given any other medication
Results:Seventy colonoscopies were performed in
this study. Forty of them were male and the rest were
female. The mean age was 42 years ranging from 4
years to 85 years. The most common indication for
colonoscopy was rectal bleeding (44%) Polyethylene
glycol lavage solution was used in all patients for
bowel preparation. All patients did not receive premedications. Complete colonoscopy examination was
done in (12.8%) of patients, the most common cause
of incomplete examination was poor bowel preparation (50%). No complications were reported.
Conclusions: Rectal bleeding was the most common
indication for colonoscopy. Poor bowel preparation
was the main cause of incomplete colonoscopy.
order to increase the level of security, as this system encrypts the secret image before sending it through the internet to the recipient (by the Blowfish method). As The Blowfish method is known for its efficient security; nevertheless, the encrypting time is long. In this research we try to apply the smoothing filter on the secret image which decreases its size and consequently the encrypting and decrypting time are decreased. The secret image is hidden after encrypting it into another image called the cover image, by the use of one of these two methods" Two-LSB" or" Hiding most bits in blue pixels". Eventually we compare the results of the two methods to determine which one is better to be used according to the PSNR measurs
This study investigates the phonotactics of English obstruent clusters in the word-final position from a markedness theory perspective among Iraqi EFL College Students whose native language, Arabic, prefers only two-member word-final obstruent cluster as a maximum. The markedness of clusters is measured depending on Iraqi EFL College Students’ utilization of the simplification strategies. This study tries to answer whether or not word-final obstruent clusters are marked or unmarked for Iraqi EFL College Students, and whether or not the markedness of the obstruent cluster increases as to its length. In order to answer these questions, a test has been distributed among 60 Iraqi EFL Fourth-Year College students, Department of English, Colleg
... Show MoreAA wahid, journal mustansiriyah of sports science, 2023
تعد لعبة كرة السلة من الألعاب الرياضية التي تحتاج متطلبات بدنية ووظيفية خاصة بها، وذلك من خلال الانتقال داخل الملعب بالكرة أو بدونها والسبل للتخلص من ملاحقة الخصم أثناء الدفاع وكيفية المناورة أثناء الهجوم مع إجادة التصويب بكافة أنواعه داخل الملعب، ومن هنا تكونت مشكلة البحث في كيفية تطوير تلك العوامل الوظيفية والتي لها الأثر في الارتقاء بمستوى أداء اللاعب أثناء اللعب، وعن طريق استخدام الباحثان لطريقة جهاز ا
... Show MoreA new Turbidimetric method characterized by simplicity, accuracy and speed for determination of Hydronium ion by continuous flow injection analysis. The method was based on the formation of complex Zn3[Fe(CN)6] for Zinc(II) that was eluted by Hydronium ion from cation exchanger column with Potassium hexacyanoferrate(III) for the formation of a pale yellow precipitate and this precipitate was determined using homemade Linear Array Ayah-5SX1-T-1D continuous flow injection analyser. The optimum parameters were 2.7 mL.min-1 flow rate using H2O as a carrier stream, 1.7 mL.min-1 reagent stream, 110 L sample volume and open valve for the purge of the sample segment. Data treatment shows that linear range 0.01-0.1 mol.L-1 for each acids (HClO
... Show MoreA simple, rapid and sensitive spectrophotometric method has been proposed for the determination of La (III) using 3-hydroxy -4-(2-hydroxy-phenyl azo) naphthalene -1- sulfonic acid as a chromogenic reagent. This method is based on the formation of a red-pink colored complex, upon the reaction of La(III) with the reagent in an alkaline medium (pH= 9.50), having a maximum absorbance at 459 nm. Beer's law is valid in the concentration range 0.512 µg.ml-1 with a Sandell's sensitivity value of 0.0188 µg.cm-2 and molar absorptivity of 7376.12 L.mol-1.cm-1. The stoichiometric composition of the chelate is 1:3. The effect of the presence of different cations as interferants in the determination of La(III) under the given optimum conditions
... Show More