Background: Salvia officinalis is a plant belong to
Labiatae family .The common name of Salvia is sage
which mean save. The leaves of Salvia have special
oil which is effective against filamentous fungi and
yeasts such as Candida albicans which is the
causative agent of vaginal candidiasis in women
Methods. Cultures from 50 swabs of Candida
albicans isolated from vagina of 70 patient women
who complains from vaginal problems, their ages
(24-43) years from Central City Hospital during
Febreoury 2009 to April 2009 were cultured on
Sabouraud Dextrose Agar (SDA) .Nystatin was used
as positive reference standard to determine the
sensitivity of this fungus . and less this concentration
there was no minimum inhibition for the Candida
Results: The aqueous extract of Salvia officinalis at
various concentrations inhibited the growth of C.
Albicans . This inhibitions reached to a maximum of
100% for extract at 25 mg / ml and the minimum
inhibition was 170 mm at 15 mg /ml for the extract .
While the minimum and maximum inhibition for
nystatin was at 50 μg/ml,and less concentration. There
was no minimum inhibition for the Candida
Conclutions : The findings provide support for the
use of this plant in traditional medicine for fungal
infections especially against candidiasis .
Laboratory studies were conducted at the biological control unit, college of Agriculture, University of Baghdad to evaluate some biological aspects of the predator Chilocorus bipustulatus (Coleoptera: Coccinellidae), which is considered one of the most important predators on many insect pests, especially the scale insect, Parlatoria blanchardi, (Homoptera: Diaspididae) on date palms. The results showed that biological parameters of the predator were varied according to different degree of temperature. Egg incubation period was significantly different and reached to 7.5 and 5.44 day at 25 and 30°C respectively, Fertility was the same 100% at both temperature degrees. Larval growth periods were 17.41 and 16.12 day as well as the mortality du
... Show MoreIn this work, electrochemical process was presented to polymerized eugenol on Gr.2 and Gr.5 titanium alloys before and after treated by Micro Arc Oxidation (MAO), where Gr.2 is commercial pure titanium and Gr.5 is Ti-6Al-4V dental alloys. The deposited layers were characterized by scanning electron microscopy (SEM), energy-dispersive X-ray spectroscopy (EDS), X-ray diffraction (XRD), and Fourier transform infrared spectroscopy (FTIR). The adhesion strength of polymeric thin-film was estimation by using pull-off adhesion test and the result was the adhesion strength of PE was (1.23 MPa) on Gr.2 before MAO and increase to (1.98 MPa) on Gr.2 after MAO treatment. The corrosion behavior of Gr.2 and Gr.5 alloy in artificial saliva environment at
... Show More2-benzamide benzothiazole complexes of Pd(II) , Pt(IV) and Au(III) ions were prepared by microwave assisted radiation. The ligand and the complexes were isolated and characterized in solid state by using FT-IR, UV-Vis spectroscopy, flame atomic absorption, elemental analysis CHNS , magnetic susceptibility measurements , melting points and conductivity measurements. The nature of complexes in liquid state was studied by following the molar ratio method which gave results approximately identical to those obtained from isolated solid state; also, stability constant of the prepared complexes were studied and found that they were stable in molar ratio 1:1.The complexes have a sequar planner geometry except Pt(IV) complex has octahedral .
... Show MoreThe adsorption behavior of Bismarck brown (BB) dye from aqueous solutions onto graphene oxide GO and graphene oxide-g-poly (n-butyl methacrylate-co-methacrylic acid) GO-g-pBCM as adsorbents was investigated. The prepared GO and GO-g-pBCM were characterized by Fourier transform infrared spectroscopy FTIR, which confirmed the compositions of the prepared adsorbents. Adsorption of BB dye onto GO and GO-g-pBCM was explored in a series of batch experiments under various conditions. The data were examined utilizing Langmuir and Freundlich isotherms. The Langmuir isotherm was seen as increasingly reasonable from the experimental information of dye on formulating adsorbents. Kinetic investigations showed that the experimental data were fitted ve
... Show MoreÖz
Arzı Kanber/Kamber hikayesi Anadolu, Rumeli, Azerbaycan, Türkmenistan ve Irak gibi Türk dünyasının birçok yerinde birden fazla varyantı bulunan, çok sevilen ve yaygın olarak anlatılan aşk ve dramatik maceralı bir halk hikayesidir. Türk halk hikayelerinin en popüler olanlarından biri sayılan Arzı Kanber/Kamber hikayesi, Anadolu'nun birçok yöresinde bilinmesine rağmen Irak Türkmenleri arasında daha çok sevildiği ve yaygın olarak anlatıldığı tespit edilen birden fazla varyantından da görülebilir. Irak Türkmenleri arasında günümüze kadar hikayenin iki varyantı tespit edilmi
... Show MoreThis paper investigates the performance evaluation of two state feedback controllers, Pole Placement (PP) and Linear Quadratic Regulator (LQR). The two controllers are designed for a Mass-Spring-Damper (MSD) system found in numerous applications to stabilize the MSD system performance and minimize the position tracking error of the system output. The state space model of the MSD system is first developed. Then, two meta-heuristic optimizations, Simulated Annealing (SA) optimization and Ant Colony (AC) optimization are utilized to optimize feedback gains matrix K of the PP and the weighting matrices Q and R of the LQR to make the MSD system reach stabilization and reduce the oscillation of the response. The Matlab softwar
... Show MoreThe aim of the study was to evaluate the efficacy of diode laser (λ=940 nm) in the management of gingival hyperpigmentation compared to the conventional bur method. Materials and methods: Eighteen patients with gingival hyperpigmentation were selected for the study with an age between 12-37 years old. The site of treatment was the upper gingiva using diode laser for the right half and the conventional method for the left half. All patients were re-evaluated after the following intervals: 3 days, 7 days, 1 month and 6 months post-operation. Pain and functions were re-evaluated in each visit for a period of 1 day, 3 days and 1 week post-operation. Laser parameters included 1.5 W in continuous mode with an initiated tip (400 μm) placed in
... Show More