Preferred Language
Articles
/
jkmc-644
Comparison Between Mechanical and Non Mechanical Bowel Preparation Prior To Elective Colorectal Surgery
...Show More Authors

Background: Bowel preparation prior to
colonic surgery usually includes antibiotic
therapy together with mechanical bowel
preparation which may cause discomfort to the
patients, prolonged hospitalization and water
& electrolyte imbalance.
Objective: to assess whether elective colon
and rectal surgery may be safely performed
without preoperative mechanical bowel
preparation.
Method: the study includes all patients who
had elective large bowel resection at Medical
City – Baghdad Teaching Hospital between
Feb, 2007 to Jan, 2010. Emergency operations
were not included. The patients were randomly
assigned to the 2 study groups (with or without
mechanical bowel preparation.
Results: A total of 165 patients participated
in the study, 82 with mechanical bowel
preparation and 83 without. The 2 groups
were similar in age, sex and type of surgical
procedure. 134 patients (81.2 %) underwent
surgery owing to colorectal cancer & 31
patients (18.8 %) owing to benign disease.
The hospitalization period was longer in the
bowel-prepared group (mean ± SD, 8.2 ± 5.1
days) as compared with the non prepared
group (mean ± SD, 8.0 ± 2.7 days). However,
this difference was not statistically significant.
The time until the 1st bowel movement was
similar between the 2 groups : a mean ± SD of
4.2 ± 1.3 days in the non prepared group as
compared with a men ± SD 4.3 ± 1.1 days in
the prepared group ( P = NS ).
Conclusion: Our results suggest that no
advantage is gained by preoperative
mechanical bowel preparation in elective
colorectal surgery.

View Publication Preview PDF
Quick Preview PDF
Publication Date
Sun Jun 06 2010
Journal Name
Baghdad Science Journal
Stochastic Non-Linear Pseudo-Random Sequence Generator
...Show More Authors

Many of the key stream generators which are used in practice are LFSR-based in the sense that they produce the key stream according to a rule y = C(L(x)), where L(x) denotes an internal linear bit stream, produced by small number of parallel linear feedback shift registers (LFSRs), and C denotes some nonlinear compression function. In this paper we combine between the output sequences from the linear feedback shift registers with the sequences out from non linear key generator to get the final very strong key sequence

View Publication Preview PDF
Crossref
Publication Date
Sun Jun 03 2012
Journal Name
Baghdad Science Journal
Study of Liver and Kidney functions in non-pregnant, pregnant and preeclamptic women
...Show More Authors

Three groups of subjects have been divided (25/group): healthy normotensive non-pregnant women (Group A), normal normotensive pregnant women (Group B), and women with preeclampsia (Group C).The levels of serum alanine aminotransferase (ALT), aspartate aminotransferase (AST), total bilirubin , creatinine , blood urea nitrogen, triglyceride , total cholesterol and glucose have been estimated in all subjects. All measured parameters were determined by spectrophotometric analysis. The results showed a significant(P<0.05) increase in serum ALT, AST, blood urea nitrogen, triglyceride and total cholesterol levels in group B as compared to group A. However creatinine, total bilirubin and glucose levels did not show any statistical significant alt

... Show More
View Publication Preview PDF
Crossref
Publication Date
Wed Mar 29 2017
Journal Name
Iraqi Journal Of Pharmaceutical Sciences ( P-issn 1683 - 3597 E-issn 2521 - 3512)
Preparation and Evaluation of Chloramphenicol as Thermosensitive Ocular in- situ Gel
...Show More Authors

The purpose of this study was to develop poloxamer-based in-situ gel of chloramphenicol aiming to increase bioavailability and prolong corneal contact time, controlling drug release, and enhancing ocular bioavailability. The in-situ gel was prepared using different concentrations of poloxamer 407 combined with hydroxypropyl methyl cellulose (HPMC) or carbapol 940 to achieve gelation temperature about physiological temperature and improve rheological behavior and gelling properties of poloxamer gel. The prepared formulations were evaluated for their appearance, pH, and sol-gel transition temperature. The formulations F2, F3, and F5 have a gelation temperature within the accepted range 35-370C an

... Show More
View Publication Preview PDF
Crossref (2)
Crossref
Publication Date
Sat Mar 01 2014
Journal Name
Eeng. &tech.journal
Preparation and Characterization of High Quality SnO2 Films Grown by (HPCVD)
...Show More Authors

ABSTRACT: In this research SnO2 thin films have been prepared by using hot plate atmospheric pressure chemical vapor deposition (HPCVD) on glass and Si (n-type) substrates at various temperatures. Optical properties have been measured by UV-VIS spectrophotometer, maximum transmittance about (94%) at 400 0C. Structure properties have been studied by using X-ray diffraction (XRD) , its shows that all films have a crystalline structure in nature and by increasing growth temperature from(350-500) 0C diffraction peaks becomes sharper and grain size has been change. Atomic force microscopy (AFM) uses to analyze the morphology of the Tine Oxides surface structure. Roughness & Root mean square for different temperature have been investigated. The r

... Show More
Preview PDF
Publication Date
Mon Jan 01 2018
Journal Name
Journal Of Pharmacy Research
Preparation and characterization of lacidipine as an oral fast dissolving film
...Show More Authors

Background: Fast dissolving oral drug delivery system is solid dosage form which disintegrates or dissolves within second when placed in the mouth without need of water or chewing. In present investigation, an attempt has been made to develop oral fast dissolving film of calcium channel blocker lacidipine. Method: Five formulas were prepared by solvent casting method using HPMC (METOLOSE)® as a film forming polymer and evaluated for their physical characteristics such as thickness, weight variation, folding endurance, drug content, disintegration time and in vitro drug release. The compatibility of the drug in the formulation was confirmed by FTIR and DSC studies. Result and Conclusion: The optimized formula F1 showed minimum in vitr

... Show More
Scopus (2)
Scopus
Publication Date
Sun Sep 30 2001
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Preparation and Agglomeration of Zeolite 5A from Locally Available Raw Materials
...Show More Authors

View Publication Preview PDF
Publication Date
Wed Jun 29 2022
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Studying and Analyzing Operating Conditions of Hollow Fiber Membrane Preparation Process
...Show More Authors

Polymeric hollow fiber membrane is produced by a physical process called wet or dry/wet phase inversion; a technique includes many steps and depends on different factors (starting from selecting materials, end with post-treatment of hollow fiber membrane locally manufactured). This review highlights the most significant factors that affect and control the characterization and structure of ultrafiltration hollow fiber membranes used in different applications.        Three different types of polymers (polysulfone PSF, polyethersulfone PES or polyvinyl chloride PVC) were considered to study morphology change and structure of hollow fiber membranes in this review. These hollow fiber membranes were manufactured with different proce

... Show More
View Publication
Crossref
Publication Date
Mon Aug 01 2016
Journal Name
Journal Of Engineering
Preparation and Characterization of Activated Carbon for Adsorption of Fluoroquinolones Antibiotics
...Show More Authors

           In this research, the preparation of a chemically activated carbon from date stones by using electric and microwave assisted K2CO3 activation was studied. The effect of radiation power, radiation time, and impregnation ratio on the yield and Iodine number on the activated carbons was investigated. The activated carbon characterizations were examined by its surface area, pore structure analysis, bulk density, moisture content, ash content, iodine number, FTIR, and scanning electron microscopy (SEM). The adsorption capacity was also studied by adsorption of fluoroquinolones antibiotics, CIP, NOR, and LEVO, by the prepared activated carbon.

... Show More
View Publication Preview PDF
Publication Date
Fri Apr 28 2023
Journal Name
Surgical Neurology International
Neurosurgery theater-based learning: Etiquette and preparation tips for medical students
...Show More Authors

View Publication Preview PDF
Scopus (1)
Crossref (1)
Scopus Crossref
Publication Date
Wed Dec 12 2018
Journal Name
Iop Conference Series: Materials Science And Engineering
Preparation and characterization DLC thin films using atmospheric pressure plasma Jet
...Show More Authors

Diamond-like carbon, amorphous hydrogenated films forms of carbon, were pretreated from cyclohexane (C6H12) liquid using plasma jet which operates with alternating voltage 7.5kv and frequency 28kHz. The plasma Separates molecules of cyclohexane and Transform it into carbon nanoparticles. The effect of argon flow rate (0.5, 1 and 1.5 L/min) on the optical and chemical bonding properties of the films were investigated. These films were characterized by UV-Visible spectrophotometer, X-ray diffractometer (XRD) Raman spectroscopy and scanning electron microscopy (SEM). The main absorption appears around 296, 299 and 309nm at the three flow rate of argon gas. The value of the optical energy gap is 3.37, 3.55 and 3.68 eV at a different flow rate o

... Show More
View Publication
Scopus (6)
Crossref (2)
Scopus Clarivate Crossref