Background: Plants used in folk medicine for
the treatment of peptic ulcer diseases is a very
promising approach to overcome the limitations of
classical medicines.
Aim: To explore the efficacy of medicinal
plants, namely turmeric, garlic and marshmallow,
in eradication of H. pylori.
Methods: This prospective study was carried out
on 225 of well-known dyspeptic patients who were
divided into four groups; a control group (received
classical medical therapy) and three other groups
that received one of the three medicinal plants,
plus the same therapy used in the control group.
The follow up was done by using a questionnaire
form, endoscopic examination, and determination
of serum levels of anti H.pylori antibodies &
gastrin by using ELISA test. In addition, liver
enzymes were monitored by using spectrophotometer
to prove the safety of medicinal plants.
Results: The rate of recurrence of peptic ulcer
disease was decreased in patients who received the
combined therapy when compared to the patients
in control group. Medicinal plants were effective
in decreasing the recurrence of H. pylori infection
when each one of them was used in combination
with the medical therapy without causing harmful
effects on the liver.
Conclusion: Turmeric, garlic & marshmallow
are effective in management of peptic ulcer with
low cost.
To evaluate the shear bond strength and interfacial morphology of sound and caries-affected dentin (CAD) bonded to two resin-modified glass ionomer cements (RMGICs) after 24 hours and two months of storage in simulated body fluid at 37°C.
Sixty-four permanent human mandibular first molars (32 sound and 32 with occlusal caries, following the International Caries Detection and Assessment System) were selected. Each prepared substrate (sound and CAD) was co
Advanced strategies for production forecasting, operational optimization, and decision-making enhancement have been employed through reservoir management and machine learning (ML) techniques. A hybrid model is established to predict future gas output in a gas reservoir through historical production data, including reservoir pressure, cumulative gas production, and cumulative water production for 67 months. The procedure starts with data preprocessing and applies seasonal exponential smoothing (SES) to capture seasonality and trends in production data, while an Artificial Neural Network (ANN) captures complicated spatiotemporal connections. The history replication in the models is quantified for accuracy through metric keys such as m
... Show MoreThis study proposed using color components as artificial intelligence (AI) input to predict milk moisture and fat contents. In this sense, an adaptive neuro‐fuzzy inference system (ANFIS) was applied to milk processed by moderate electrical field‐based non‐thermal (NP) and conventional pasteurization (CP). The differences between predicted and experimental data were not significant (
Hydrate dissociation equilibrium conditions for carbon dioxide + methane with water, nitrogen + methane with water and carbon dioxide + nitrogen with water were measured using cryogenic sapphire cell. Measurements were performed in the temperature range of 275.75 K–293.95 K and for pressures ranging from 5 MPa to 25 MPa. The resulting data indicate that as the carbon dioxide concentration is increased in the gas mixture, the gas hydrate equilibrium temperature increases. In contrast, by increasing the nitrogen concentration in the gas mixtures containing methane or carbon dioxide decreased the gas hydrate equilibrium temperatures. Furthermore, the cage occupancies for the carbon dioxide + methane system were evaluated using the Van der Wa
... Show MoreCompression study of Irisin, Vitamin D and Kidney Function Parameters Between Iraqi Fracture Patients with and Without DM2 and Healthy Control, Omar Yousif Majnun*, Altaie AF
Each Intensity Modulated Radiation Therapy (IMRT) plan needs to be tested and verified before any treatment to check its quality. Octavius 4D-1500 phantom detector is a modern and qualified device for quality assurance procedure. This study aims to compare the common dosimetric criteria 3%/3 mm with 2%/2 mm for H&N plans for the IMRT technique. Twenty-five patients with head and neck (H&N) tumor were with 6MV x-ray photon beam using Monaco 5.1 treatment planning software and exported to Elekta synergy linear accelerator then tested for pretreatment verification study using Octavius 4D-1500 phantom detector. The difference between planned and measured dose were assessed by using local and global gamma index (GI) analysis method at
... Show More