Background: The prevalence of obesity is continuously rising world-wide. Obesity is an important risk factor of cardiovascular disease (CVD), metabolic syndrome (MS), and type 2 diabetes (T2D).
Objective: To estimate the frequency of MS in obese versus non-obese subjects in Basrah, Iraq .
Methods: This is a prospective clinical study performed in Al-Sadr Teaching Hospital, Basrah, and included 86 obese subjects (with a BMI ≥ 30), 39 males and 47 females, and 132 non-obese subjects ( with a BMI < 30 ), 60 males and 73 females as a control group. Measurement of height, weight, waist circumference (WC), blood pressure ( BP ), fasting blood glucose ( FBG ), total cholesterol (TC), triglycerides (TG ) and high density lipoprotein- cholesterol (HDL-C) levels were carried out. The updated US National Cholesterol Education Program Adult Treatment Panel III ( updated NCEP ATP III ) definition was used for the diagnosis of MS.
Results: The frequencies of MS were significantly higher among obese male and female persons (38.5% and 42.6% respectively) compared to non-obese male and female persons (15.0% and 19.4% respectively), (P<0.01). On the other hand, the frequencies of MS were non-significantly higher among over weight male and female subjects (19.2% and 24.3% respectively) compared to normal weight male and female subjects (11.8% and 14.3% respectively), (P>0.05). The major determinants for MS in obese persons in either sex were WC, BP and TG ( P<0.001, P<0.001 and P<0.05 respectively).
Conclusions: Obese individuals are at a substantial risk for MS, and thereby, at a high risk of atherosclerotic CVD and T2D, and their complications.
Based on a finite element analysis using Matlab coding, eigenvalue problem has been formulated and solved for the buckling analysis of non-prismatic columns. Different numbers of elements per column length have been used to assess the rate of convergence for the model. Then the proposed model has been used to determine the critical buckling load factor () for the idealized supported columns based on the comparison of their buckling loads with the corresponding hinge supported columns . Finally in this study the critical buckling factor () under end force (P) increases by about 3.71% with the tapered ratio increment of 10% for different end supported columns and the relationship between normalized critical load and slenderness ratio was g
... Show MoreIn this work, we study several features of the non-zero divisor graphs (ℵZD- graph) for the ring Zn of integer modulo n. For instance, the clique number, radius, girth, domination number, and the local clustering coefficient are determined. Furthermore, we present an algorithm that calculates the clique number and draws the non-zero divisor for the ring Zn.
In all process industries, the process variables like flow, pressure, level, concentration
and temperature are the main parameters that need to be controlled in both set point
and load changes.
A control system of propylene glycol production in a non isothermal (CSTR) was
developed in this work where the dynamic and control system based on basic mass
and energy balance were carried out.
Inlet concentration and temperature are the two disturbances, while the inlet
volumetric flow rate and the coolant temperature are the two manipulations. The
objective is to maintain constant temperature and concentration within the CSTR.
A dynamic model for non isothermal CSTR is described by a first order plus dead
time (FO
Ultraviolet photodetectors have been widely utilized in several applications, such as advanced communication, ozone sensing, air purification, flame detection, etc. Gallium nitride and its compound semiconductors have been promising candidates in photodetection applications. Unlike polar gallium nitride-based optoelectronics, non-polar gallium nitride-based optoelectronics have gained huge attention due to the piezoelectric and spontaneous polarization effect–induced quantum confined-stark effect being eliminated. In turn, non-polar gallium nitride-based photodetectors portray higher efficiency and faster response compared to the polar growth direction. To date, however, a systematic literature review of non-polar gallium nitride-
... Show MoreObjective: To compare two positioning approaches in the surgical treatment of unstable intertrochanteric femoral fractures fixed by proximal femoral nailing, the supine versus lateral decubitus position Methodology: This randomized prospective comparative study on 26 patients with unstable intertrochanteric fractures was carried out from January 2020 and June 2022. We randomly divided patients into two groups: group A (13 patients) were operated using the traction table in the supine position for implant insertion, and group B (13 patients) were operated using the lateral decubitus position. We compared both groups regarding the setup time, operative time, tip-to-apex distance, collodiaphyseal angle, time for fluoroscopic time expo
... Show MoreKE Sharquie, AA Noaimi, MR Al-Karhi, J Clin Dermatol Ther, 2014 - Cited by 8
Background: Fractures of patella constitute 1% of all fractures. Various techniques have been described for internal fixation of patella fractures. Superiority of one technique over the other has long been debated. Objective: We reviewed a series of seventy patients with transverse or comminuted fractures of patella treated with cerclage and tension band wiring technique to assess if it had any advantages over k. wires and tension band wiring technique. Type of the study: Retrospective study. Methods; Seventy patients with displaced patella fracture, with a mean age of 47 years (range 13-75) were divided into two groups :group A 36 patients were treated with cerclage and tension bands technique ,and group B 34 patients were fixed by 2 K.
... Show More