Background:Fractures of patella constitute 1% of all fractures. Various techniques have been described for internal fixation of patella fractures. Superiority of one technique over the other has long been debated. Objective:We reviewed a series of seventy patients with transverse or comminuted fractures of patella treated with cerclage and tension band wiring technique to assess if it had any advantages over k. wires and tension band wiring technique. Type of the study:Retrospective study.Methods; Seventy patients with displaced patella fracture, with a mean age of 47 years (range 13-75) were divided into two groups :group A 36 patients were treated with cerclageand tension bands technique ,and group B 34 patients were fixed by 2 K. wires and tension bands technique. Clinical outcome was assessed using the system of Bostman score. Range of motion and evidence of radiological union were assessed at regular follow-ups. Results; All patients in group A gained Excellent result and good result, while only one patient gained poor result in group B . One patient (2.8%) developed superficial infection in group A and three patients( 8.8% ) developed superficial infection in group B. All fractures had united at the end of 10 weeks. Twenty two patients (31.4%) underwent a second surgery for wire removal; 5 cases in group A ( 13.9 % ) two of them due to implant related complications and 15 ( 44.1%) patients for group B mainly due to pain and interference with daily activity. Malunion or non-union was not noted in any of the cases. . Conclusion; The advantages of the cerclage and tension bands technique for fixation of displaced patella fracture are early mobilization, elimination of k-wire related complications, and ease of use in comminuted fracture pattern as well and a lower reoperation rates as compared to other method of fixation by 2 K. wires and tension bands technique. We strongly recommend its use in cases of displaced comminuted transverse fractures of patella
Background: Fractures of patella constitute 1% of all fractures. Various techniques have been described for internal fixation of patella fractures. Superiority of one technique over the other has long been debated. Objective: We reviewed a series of seventy patients with transverse or comminuted fractures of patella treated with cerclage and tension band wiring technique to assess if it had any advantages over k. wires and tension band wiring technique. Type of the study: Retrospective study. Methods; Seventy patients with displaced patella fracture, with a mean age of 47 years (range 13-75) were divided into two groups :group A 36 patients were treated with cerclage and tension bands technique ,and group B 34 patients were fixed by 2 K.
... Show MoreBACKGROUND: Transverse fractures of the patella are important fractures with a wide variety of subtypes, the common incidence in the age group of 20–50 years. Surgical interference aims to achieve a perfect alignment of the joint surface, in addition to rigid fixation of the fracture for early re-habitation and early movement to retain the extensor mechanism of the knee joint. AIM: The aim of this study was to compare the radiological and functional outcomes of the displaced transverse patella fracture in adult patients treated by ORIF using tension band wiring versus cannulated screws with wiring. METHODS: A prospective analytic comparative study was conducted in Al-Kindy Teaching Hospital/Baghdad/Iraq for 18 months from Apr
... Show MoreBackground: Fracture dislocation at the junction between thoracic and lumber segments of spinal column by direct or indirect high energy force which is usually managed with more than three vertebral level fixation. Short segment stabilization have a wide range of benefits including length of time utilized for surgical intervention, reduce functional and psychological disability postoperatively and local surgical site complications.
Objective: Evaluate the efficacy of posterior short segment pedicle stabilization in T-L fracture clinically and radiologically. Also to compare outcome of pedicle fixation by long segment and short segment an finally we try to insert at least one screw in the fracture vertebra to strengthen the stabilizati
The molar ratio(x) of Li-Ni ferrites in the formula Li0.5-0.5xNixFe2.5-
0.5xO4 was varied in range 0.1-1.0 by hydrothermal process. The
XRD, SEM, and TEM tests were conducted to examine the samples
crystalline phase and to characterize the particles shapes and sizes.
The high purity spinel structure was obtained at med and high x
values. SEM and TEM images showed the existence of different
ferrite particles shapes like nanospheres and nanorods. The
maximum particle size is around (20nm). These size encourage
occurrence of super paramagnetic state. The reflection loss and
insertion loss as microwave losses of Li-Ni ferrite-epoxy composite
of 1mm thickness and mixing ratio 39.4 wt was investigated. The
mini
Abstract
The aim of the present research is to identify the test wisdom and the preoccupation with learning and psychological tension among postgraduate students at the University of Samarra according to the variables of the department, gender, age, and employee or non-employee, and revealing the relationship between the test wisdom and the preoccupation with learning and psychological tension. The research sample consisted of (75) students randomly selected from postgraduate students at the college of Education. The researcher applies test –wisdom of (Mellman & Ebel) and measurement of preoccupation with learning prepared by (Al-zaabi 2013) also, the researcher used the scale of t
... Show MoreRecent advances in wireless communication systems have made use of OFDM technique to achieve high data rate transmission. The sensitivity to frequency offset between the carrier frequencies of the transmitter and the receiver is one of the major problems in OFDM systems. This frequency offset introduces inter-carrier interference in the OFDM symbol and then the BER performance reduced. In this paper a Multi-Orthogonal-Band MOB-OFDM system based on the Discrete Hartley Transform (DHT) is proposed to improve the BER performance. The OFDM spectrum is divided into equal sub-bands and the data is divided between these bands to form a local OFDM symbol in each sub-band using DHT. The global OFDM symbol is formed from all sub-bands together using
... Show MoreHypothesis Nanofluid flooding has been identified as a promising method for enhanced oil recovery (EOR) and improved Carbon geo-sequestration (CGS). However, it is unclear how nanoparticles (NPs) influence the CO2-brine interfacial tension (γ), which is a key parameter in pore-to reservoirs-scale fluid dynamics, and consequently project success. The effects of pressure, temperature, salinity, and NPs concentration on CO2-silica (hydrophilic or hydrophobic) nanofluid γ was thus systematically investigated to understand the influence of nanofluid flooding on CO2 geo-storage. Experiments Pendant drop method was used to measure CO2/nanofluid γ at carbon storage conditions using high pressure-high temperature optical cell. Findings CO2/nano
... Show More