Background: Humeral diaphyseal fracture usually
heals with closed methods but when nonunion
develops then it needs surgical intervention in the
form of plating and bone grafting, intramedulary
nailing (open or closed simple or interlocking nails)
and external fixators (circular or one plane fixator).
In our unit we treated non union humeral
diaphyseal fracture with plating and bone grafting
shortening of fracture ends up to 4 to 5cm when
needed. Methods: This study was conducted at
Orthopaedic Department of AL-Sadar General
Hospital from January 2004 till December2005 .
We included 20 cases with atrophic non-union in
12(60%) and hypertrophic non-union in 8 (40%)
patients. All atrophic non-union were treated with
plating, bone shortening by transverse osteotomy
and bone grafting, while hypertrophic non-union
were treated with decortications of non-union ends
and fixation with compression plates, with bone
grafting in old age. Follow up measures were based
on clinical (range of joints motion) and radiological
(healing) findings. Follow up was done for upto 6
months . Results: Out of 20 patients the age range
was 20- 60 years, 16 (80%)were male and 4(20%)
female. Right humerus involved in 15( 75 %)
while left humerus in 5( 25%) patients.
In12(60%) patients with atrophic non union bone
shortening by transverse cut osteotomy was done
while in remaining patients with hypertrophic nonunion
plating was done in 2( 10 %) cases and
plating with bone grafting in 6( 30%) patients.
Union was achieved in all patients after 16 to 20
weeks of surgery. In one patient ( 5 %) of 75 years
age with hypertrophic non-union implant was
loosened after 3 months of surgery. At that time
healing (Union) was evident on X-rays and humeral
brace was applied for further 3 months. Two
patients( 10 %) got neuropraxia of radial nerve
which resolved with in 3 months time. 2 patients
(10 %) developed shoulder stiffness which resolved
after exercise. Conclusion: In Non Union of
Humerus shortening by transverse osteotomy &
rigid fixation with plates give excellent results in
selected cases.
Background: Trauma to the anterior teeth is a common injury in young children. Themaxillary incisors being the most affected. Although root fractures are rare, theydo occur and were previously and often considered hopeless and were extracted.The time between the injury and the initiation of treatment, level of the fractureline, and stage of root development are some criteria to be considered whenchoosing a treatment approach for a complicated tooth fracture. This case reportdescribes the management of a traumatized immature maxillary central incisorwith Elise class IV fracture with vertical oblique subgingival fracture of the root.Materials and method: Apexification was carried out using biodentine followed byremoval of the fracture
... Show MoreHuman relationships are shaped and affected by the place they live in. This article analyzes Lynn Nottage’s Sweat from the perspective of spatial theory, particularly using the theories of Yi-Fu Tuan and Doreen Massey, to explore the complex connection between place and human relationships. The article examines how Nottage presents the reciprocal effect between people and their setting. By examining the city, the factory, and the local community around it, the study shows how place serves as a dynamic force that shapes the characters’ identities and relationships rather than just serving as a background. While Massey’s concept of place as a product of social relations offers a framework to explore the tensions and solidarity that aris
... Show MoreBackground: Esthetic correction represents one of the clinical conditions that required the use of laminate veneers in premolars region. Aim of the study: The purpose of this study was to evaluate the fracture strength of the laminate veneers in maxillary first premolars, fabricated from either composite (direct and indirect techniques) or ceramic CAD/CAM blocks. Materials and Methods: Fifty sound human maxillary premolar teeth were used in this in vitro study. Teeth were divided randomly into one control group and four experimental groups of ten teeth each; Group A: Restored with direct composite veneer (Filtek Z250 XT), Group B: Restored with indirect composite veneers (Filtek Z250 XT), Group C: Restored with lithium disilicate ceramic CA
... Show MoreBackground: This study was performed to compare the marginal fit changes and facture resistance of metal ceramic crowns constructed from Ceramill Sintron metal coping veneered with three different porcelain veneering materials (Vita Master Koromikos VMK, Willi Geller Creation CC and GC initial MC), also to evaluate the influence of thermocycling on load at fracture. Materials and Methods: Master brass die was scanned ,then metal coping was designed and milled from Ceramill Sintron blank to get 60 metal copings, then divided randomly into three groups(20 sample), then veneered with porcelain: VITA, Creation or GC. The marginal gaps were measured before and after porcelain veneering then marginal fit changes was calculated. Fracture resist
... Show MoreCriticism is inherently impolite and a face-threatening act generally leading to conflicts among interlocutors. It is equally challenging for both native and non-native speakers, and needs pre-planning before performing it. The current research examines the production of non-institutional criticism by Iraqi EFL university learners and American native speakers. More specifically, it explores to what extent Iraqi EFL learners and American native speakers vary in (i) performing criticism, (ii) mitigating criticism, and (iii) their pragmatic choices according to the contextual variables of power and distance. To collect data, a discourse-completion task was used to elicit written data from 20 Iraqi EFL learners and 20 American native speaker
... Show MoreEffect of nano and micro SiO2 particles with different weight percent (2,4,6,8 and 10) %wt on the Interlaminar fracture toughness (GIc) of 16-plies of woven roving glass fiber /epoxy composites prepared by hand lay – up technique were investigated. The specimens were tested using DCB test (mode I).
Area method was used to compute the interlaminar fracture toughness. The results show that, GIc would increase with the increasing in the filler content, the main failure in microcomposites and nanocomposites was delamination in the layers, the delamination reduced with increasing in the filler content.
BACKGROUND: Volar Barton’s fracture is a shearing mechanism of injury that results in fracture and subluxation of distal end radius in which volar rim of the distal radius is displaced with hand and carpus. Open reduction and volar plate fixation ensure more stable change of displacement, preservation of reduction, and early mobilization. AIM: This study aims to assess the functional and radiological outcome results of volar Barton’s fracture treated by volar buttress plate using the demerit points system of Gartland and Werley. PATIENTS AND METHODS: This study is a prospective descriptive observational study on 32 patients who were treated with ORIF by volar buttress plate for isolated volar Barton’s fractures between Fe
... Show More