Preferred Language
Articles
/
jkmc-522
Preparation of Vaccine against Diabetic Foot Pathogenic Bacteria Using Low Level Diode Laser
...Show More Authors

Background: Since the invention of laser in 1960, lasers have been developed and approved in many fields. Lasers can now be regarded as practical tools with unique properties that have been utilized effectively in several applications in fields of medical and biological sciences.Objectives: The aim of the current study was to preparation of vaccines (live attenuated and killed) by irradiation of the bacteria by the low level diode laser.Methods: six bacterial isolates were isolated from human samples of diabetic foot infections, which used for preparation of vaccines. The experiment was conducted on fifteen adult male rabbits; they were divided into three groups with 5 rabbits each. Blood samples were collected from the marginal ear vein of the rabbits after one month of the vaccination, for the purpose of measuring the concentration of the immunoglobulins which present in their serum, using Radial Immunodiffusion (RID) method by specialized kits (LTA-Italy).Results: After irradiation of the bacterial suspensions with the diode laser for different exposure times and different frequencies, and the wavelengths used were (660, 820, 915) nm, the growth of bacterial isolates decreased until killed of bacteria at 40 min. The results of IgA concentrations for the three groups were highly significant (P < 0.01) when comparing the attenuated with control group, while were significant (P < 0.05) between the killed vaccine and control groups, and not significant variations between the attenuated and killed groups,Conclusions: Wavelength (660) nm was more effective in killing the bacteria, and the variations were not significant between the live attenuated and the killed vaccine

View Publication Preview PDF
Quick Preview PDF
Publication Date
Thu Dec 01 2011
Journal Name
Iraqi Journal Of Physics
Electronic diagnostics system for the analysis of laser beam profile
...Show More Authors

In this work the analysis of laser beam profile system ,using a two dimensional CCD (Charge Coupled Device) arrays, is established. The system is capable of producing video graphics that give a two dimensional image of laser beam. The video graphics system creates color distribution that represent the intensity distribution of the laser beam or the energy profile of the beam. The software used is capable of analyzing and displaying the profile in four different methods that is , color code intensity contouring , intensity shareholding, intensity cross section along two dimension x-y, and three dimensional plot of the beam intensity given in the same display.

View Publication Preview PDF
Publication Date
Thu May 01 2014
Journal Name
Engineering And Technology Journal
Relativistic Self-Focusing of Intense Laser Beam in Magnetized Plasma
...Show More Authors

View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Wed Jun 11 2003
Journal Name
Iraqi Journal Of Laser
Q- Switched Nd:YAG Laser Annealing of Phosphorus Diffused Silicon Photodiodes
...Show More Authors

Improvement of optoelectrical characteristics of phosphorus diffused silicon photodiodes by Q-switched Nd:YAG laser pulses was investigated. Laser pulses have dissolved the precipitation of phosphorus resulted during thermal diffusion process. The experimental data show that responsivity higher than (0.32 A/W) at 850 nm can be achieved after laser annealing with (1.5 MW/cm2) for 6 shots.

View Publication Preview PDF
Publication Date
Thu Apr 18 2024
Journal Name
Geomatics And Environmental Engineering
Error Analysis of Stonex X300 Laser Scanner Close-range Measurements
...Show More Authors

This research reports an error analysis of close-range measurements from a Stonex X300 laser scanner in order to address range uncertainty behavior based on indoor experiments under fixed environmental conditions. The analysis includes procedures for estimating the precision and accuracy of the observational errors estimated from the Stonex X300 observations and conducted at intervals of 5 m within a range of 5 to 30 m. The laser 3D point cloud data of the individual scans is analyzed following a roughness analysis prior to the implementation of a Levenberg–Marquardt iterative closest points (LM-ICP) registration. This leads to identifying the level of roughness that was encountered due to the range-finder’s limitations in close

... Show More
View Publication
Scopus (1)
Crossref (1)
Scopus Clarivate Crossref
Publication Date
Sun Mar 01 2009
Journal Name
Al-khwarizmi Engineering Journal
Investigation of Thermal Stress Distribution in Laser Spot Welding Process
...Show More Authors

The objective of this paper was to study the laser spot welding process of low carbon steel sheet. The investigations were based on analytical and finite element analyses. The analytical analysis was focused on a consistent set of equations representing interaction of the laser beam with materials. The numerical analysis based on 3-D finite element analysis of heat flow during laser spot welding taken into account the temperature dependence of the physical properties and latent heat of transformations using ANSYS code V.10.0 to simulate the laser welding process. The effect of laser operating parameters on the results of the temperature profile were studied in addition to the effect on thermal stresses  and dimensions of the laser w

... Show More
View Publication Preview PDF
Publication Date
Thu Mar 03 2022
Journal Name
Arabian Journal For Science And Engineering
Experimental Study of Cuttings Transport Efficiency of Low Solid Bentonite Drilling Fluids Modified by Cellulose Nanoparticles
...Show More Authors

Advancements in horizontal drilling technologies are utilized to develop unconventional resources, where reservoir temperatures and pressures are very high. However, the flocculation of bentonite in traditional fluids at high temperature and high pressure (HTHP) environments can lower cuttings transportation efficiency and even result in problems such as stuck pipe, decreased rate of penetration (ROP), accelerated bit wear, high torque, and drag on the drill string, and formation damage. The major purpose of the present research is to investigate the performance of low bentonite content water-based fluids for the hole cleaning operation in horizontal drilling processes. Low bentonite content water-based drilling fluids were formulated by re

... Show More
Crossref (7)
Crossref
Publication Date
Tue Aug 15 2023
Journal Name
Al-academy
Effect of partial substitution of alkaline oxides with lithium oxide (Li2O) on low-temperature ceramic glaze
...Show More Authors

The research aims to study the effect of adding (Li2O) to an alkaline glaze containing (K2O, Na2O). Although all the alkaline oxides have common properties, each oxide has something that distinguishes it. The molecular weight of (Li2O) is two times less than that of (Na2O) and three times that of (K2O). Therefore, it is added in small proportions. In addition, it is a very strong flux, so it is not used alone, but rather replaces a part of other alkaline oxides. It was added to an alkali glass that matured at a temperature of 980CO in proportions (2.0,1.4,1.2,0.8,0.4%) instead of (Na2O), using lithium carbonate (Li2CO3) as an oxide source. The glazes mixtures were applied to a white pottery body, and the samples were fired and cooled acc

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sat Aug 01 2015
Journal Name
Materials Science And Engineering: C
Antibacterial activity of magnetic iron oxide nanoparticles synthesized by laser ablation in liquid
...Show More Authors

In this study, (50–110 nm) magnetic iron oxide (α-Fe2O3) nanoparticles were synthesized by pulsed laser ablation of iron target in dimethylformamide (DMF) and sodium dodecyl sulfate (SDS) solutions. The structural properties of the synthesized nanoparticles were investigated by using Fourier Transform Infrared (FT-IR) spectroscopy, UV–VIS absorption, scanning electron microscopy (SEM), atomic force microscopy (AFM), and X-ray diffraction (XRD). The effect of laser fluence on the characteristics of these nanoparticles was studied. Antibacterial activities of iron oxide nanoparticles were tested against Gram-positive; Staphylococcus aureus and Gram-negative; Escherichia coli, Pseudomonas aeruginosa and Serratia marcescens. The results sh

... Show More
View Publication
Scopus (232)
Crossref (226)
Scopus Clarivate Crossref
Publication Date
Tue Dec 01 2020
Journal Name
Iraqi Journal Of Physics
Pulsed laser deposition to investigate structural and optical properties of lead sulfide nanostructure
...Show More Authors

In this work, the structure properties of nano Lead sulfide PbS thin films are studied. Thin samples were prepared by pulse laser deposition and deposited on glass substrates at wavelength 1064nm wavelength with a various laser energies (200,300,400,500)nm. The study of atomic force microscope (AFM) and X-ray diffraction as well as the effect of changing the laser energy on the structural properties has been studied. It has been observed that the membrane formed is of the polycrystalline type and the predominant phase is the plane (111) and (200). The minimum grain size obtained was 16.5 nm at a laser energy about 200 mJ. The results showed that thin films of average granular sizes (75 nm) could be prepared.As for the optical properties,

... Show More
View Publication Preview PDF
Crossref (6)
Crossref
Publication Date
Sun Jan 13 2019
Journal Name
Iraqi Journal Of Physics
Energy transfer process between two laser compounds coumarin 334 & rhodamine 590
...Show More Authors

In the current research the absorption and fluorescence spectrum
of Coumarin (334) and Rhodamine (590) in ethanol solvent at
different concentration (10-3, 10-4, 10-5) M had been studied. The
absorption intensity of these dyes increases as the Concentration
increase in addition to that the spectrum was shifted towards the
longer wavelength (red shift). The energy transfer process has been
investigated after achievement this condition. The fluorescence peak
intensity of donor molecule was decrease and its bandwidth will
increases on the contrary of the acceptor molecule its intensity
increase gradually and its bandwidth decreases as the acceptor
concentration increase.

View Publication Preview PDF
Crossref (1)
Crossref