Background: Febrile convulsions are the most frequent type of seizures in children under 6 years of age. Significant percentage of these children will later suffer from recurrence of febrile convulsion.Objectives: To identify the main risk factors for recurrent febrile convulsions in children.Methods: we carried out a case control study involving 89 children those who experienced first attack of febrile convulsions and 92 children with recurrent attack of febrile convulsions. The study was conducted in Central Children Teaching Hospital, Baghdad during the period 2006- 2007. Results: Compared to children with first attack of febrile convulsion, children with recurrent seizures were younger at onset (4- 12m) (67% vs. 44%), mainly male (70% vs. 51%) and had more often family history (first degree relative) history of epilepsy, low degree of temperature (45% vs. 23%) and frequent febrile illnesses (83% vs. 50%). second degree family history of febrile convulsion and onset of febrile convulsion in relation to onset of fever and type of convulsion (simple vs. complex) were not significant risk factors.Conclusions: Awareness of these risk factors should lead pediatricians to suggest administration of short course of diazepam at onset of each febrile illness to prevent recurrent febrile convulsions. Also, public education on recurrent febrile convulsions is needed.
The performance of H2S sensor based on poly methyl methacrylate (PMMA)-CdS nanocomposite fabricated by spray pyrolysis technique has been reported. XRD pattern diffraction peaks of nano CdS has been indexed to the hexagonally wurtzite structured The nanocomposite exhibits semiconducting behavior with optical energy gap of4.06eV.SEM morphology appears almost tubes like with CdS/PMMA network. That means the addition of CdS to polymer increases the roughness in the film and provides high surface to volume ratio, which helps gas molecule to adsorb on these tubes. The resistance of PMMA-CdS nanocomposite showed a considerable change when exposed to H2S gas. Fast response time to detect H2S gas was achieved by using PMMA-CdS thin film sensor. The
... Show MoreBackground: It has been well known that the success of mandibular implant- retained overdenture heavily depends on initial stability, retention and long term osseointegration this is might be due to optimal stresses distribution in surrounding bones. Types of mandibular implant- retained overdenture anchorage system and number of dental implants play an important role in stresses distribution at the implant-bone interface. It is necessary to keep the stresses below the physiologic tolerance level of the bone .since. And it is difficult to measure these stresses around bone in vivo. In the present study, finite element analysis used to study the stresses distribution around dental implant supporting Mandible implant retained overdenture Mate
... Show MoreBackground: Bladder cancer (BC) is the most common malignant tumor in the urinary tract and the tenth most common malignancy worldwide. Exosomes are 40–100 nm-diameter nanovesicles that are either released straight from the plasma membrane during budding or merged with the plasma membrane by multivesicular bodies. Objectives: To assess the proportion of serum and urinary Exosome levels in urinary bladder cancer patients, as well as their impact on the disease. Methods: From January 2023 to June 2023, a total of 45 samples of blood and urine were collected from individuals diagnosed with bladder cancer at the Ghazi Hariri Hospital for Specialized Surgery. They included 45 male and female patients, varying in age, as well as 45 heal
... Show MoreThe measurement of vitamin B1 in pure and pharmaceutical formulations was proposed by using a straightforward and sensitive spectrophotometric approach. Sulfacetamide (SFA) is diazotized, then coupled with vitamin B1 in alkaline media to produce a colored azo dye complex with a stability constant of 5.597 × 105 L/mol. The product is stable, with a maximum absorption wavelength of 489.5 nm, molar absorptivity of 10108 L/mol∙cm, Sandell's sensitivity of 0.0334 μg/cm2, detection limit of 0.0135 μg/mL, and Beer's law being observed over the concentration range of 0.2–20.0 μg/mL. The stability constant and stoichiometry of the produced azo dye were calculated using the continuous variation (Job's) and mole ratio methods. The suggested ap
... Show MoreThe objective of this research is to study experimentally and theoretically the girder vertical load share of the curved I-Girder bridges subjected to the point load in addition to the self-weigh and supper imposed dead loads. The experimental program consist of manufacturing and testing the five simply supported bridge models was scaled down by (1/10) from a prototype of 30m central span. The models carriageway central radii are 30 m, 15m or 10m. The girder spacing of the first two models is 175 mm with an overall carriageway width of 650mm. The girder spacing of the other three bridge models is 200mm with the overall carriageway width of 700 mm. The overall depth of the composite section was 164 mm. To investigate the effect of live load
... Show More