Background:Hydrocephalus is dilatation of the ventricular system due to excessive production and/ or obstruction of cerebrospinal fluid (CSF) pathways. Different surgical procedure are used to treat this disease. Ventriculo peritoneal shunt is by far the most popular technique for CSF diversion..
Objective;To compare the programmable and non-programmable valves regarding the complications of both types
Methods:This study was conducted in the Neurosurgical hospital of Baghdad/Iraq over a period of 3 years from July 2008 to August 2011.
A special inclusion criteria has been tabulated for the selection of patients..
Results:.Fifty cases with hydrocephalus admitted and diagnosed by CT scan and treated by ventriculoperitoneal shunts (Codman type).There were 11 cases with programmable valves that demanded revision and 6 patients with fixed pressure valves required revision.
Conclusions:The programmable shunt had lower complication rate in adults and it should be used cautiously in infants because of the higher complication rates.
In this work the corrosion behavior of Al metal was studied by using non- destructive testing (NDT), which is a noninvasive technique for determining the integrity of a material. The ultrasonic waves was used to measure the corrosion which occur by two corrosive medium (0.1N sodium chloride and 0.1N sodium hydroxide) and study the corrosion by weight-loss method and electrochemical method in addition to performance the microscopic inspection for the samples before and after the immersion in the corrosive medium. Corrosion parameters were interpreted in these media which involve corrosion potential (Ecorr) and corrosion current density (icorr). The results indicate that both
... Show MorePre-breakdown phenomenon was investigated within the two, non-mixed dielectric liquids; transformation oil and cresol. Finite element technique was used to follow the initiation and growth of plasma channels (streamer discharge) within pin-plane configuration. That was done for different spacing between the pin-electrode and the liquid-liquid interface. Streamer growth model assumed that, the streamer initiation occurs at the region of the highest value of electric field. Our study shows that the streamer initiates at the tip of the pin and growths toward the other electrode. The study shows, too, that the streamer path controlled by the difference of permittivity of the two liquids and spacing distance of the liquid-liquid interface fro
... Show MoreCircular data (circular sightings) are periodic data and are measured on the unit's circle by radian or grades. They are fundamentally different from those linear data compatible with the mathematical representation of the usual linear regression model due to their cyclical nature. Circular data originate in a wide variety of fields of scientific, medical, economic and social life. One of the most important statistical methods that represents this data, and there are several methods of estimating angular regression, including teachers and non-educationalists, so the letter included the use of three models of angular regression, two of which are teaching models and one of which is a model of educators. ) (DM) (MLE) and circular shrinkage mod
... Show MoreSubjects took physical fitness for health imposed on the area of research that have become an important and clear answer to the many problems resulting from the nature of dealing with modern life current actions that were needed to be hours of manual work has become accomplished by modern technology circumstance minutes, and mediated equipment And machinery. The lack of traffic rights and further burdens the intellectual and psychological pressures and the typical method of work has led to the identification of kinetic activity, thereby threatening public health in many ways stands at the forefront of these threats the problem of smoking, which causes many types of cancers, notably lung cancer. The most important reasons that led to This dr
... Show MoreThis work presents experimental research using draped prestressed steel strands to improve the load-carrying capacity of prestressed concrete non-prismatic beams with multiple openings of various designs. The short-term deflection of non-prismatic prestressed concrete beams (NPCBs) flexural members under static loading were used to evaluate this improvement. Six simply supported (NPCBs) beams, five beams with openings, and one solid specimen used as a reference beam were all tested as part of the experiment. All of the beams were subjected to a monotonic midpoint load test. The configuration of the opening (quadrilateral or circular), as well as the depth of the chords, were the varia
The banking system considered as one of the most important intermediate circle between creditor and debtors it is mean the most important funding rings in economic activity, whether finance takes the a consumer or investment form and therefore it is the main base to stimulate economic activity both on the demand side, both consumption and investment and therefore of the main motivating factors for economic growth.
The banking system depends in achieve its goals on the grants and loan recovery, or what is known credit process and according to what the importance referred to the role of the banking system, it is important to ensure the safety and efficiency of the mechanisms of banking device and safety is
... Show MoreThe main objective of this paper is to study the behavior of Non-Prismatic Reinforced Concrete (NPRC) beams with and without rectangular openings either when exposed to fire or not. The experimental program involves casting and testing 9 NPRC beams divided into 3 main groups. These groups were categorized according to heating temperature (ambient temperature, 400°C, and 700°C), with each group containing 3 NPRC beams (solid beams and beams with 6 and 8 trapezoidal openings). For beams with similar geometry, increasing the burning temperature results in their deterioration as reflected in their increasing mid-span deflection throughout the fire exposure period and their residual deflection after cooling. Meanwhile, the existing ope
... Show More In this paper the research represents an attempt of expansion in using the parametric and non-parametric estimators to estimate the median effective dose ( ED50 ) in the quintal bioassay and comparing between these methods . We have Chosen three estimators for Comparison. The first estimator is
( Spearman-Karber ) and the second estimator is ( Moving Average ) and The Third estimator is ( Extreme Effective Dose ) . We used a minimize Chi-square as a parametric method. We made a Comparison for these estimators by calculating the mean square error of (ED50) for each one of them and comparing it with the optimal the mean square