Background: Phosphodiesterase-5 (PDE-5) inhibitorsrestore nitric oxide (NO) signaling and may reducecirculating inflammatory markers, and improve metabolicparameters through a number of mechanisms. Dailyadministration of the PDE-5 inhibitor, tadalafil (TAD) mayattenuate inflammation; improve fasting plasma glucose andtriglyceride levels and body weight. This study aims toevaluate the efficacy of low dose PDE-5 inhibitor, tadalafil(TAD) in controlling dysglycemia and body weight in obesediabetic men.Methods: Forty obese men with type 2 diabetes aged 30-50years incorporated in this study, all with A1c of 7-8.5%,attending obesity unit in AL-Kindy college of medicine.Weight, height, BMI, FPG, A1c, cholesterol, TG, HDL andLDL measured for all and advised for low calories diet andincreasing exercise and randomized into 2 groups , first(control) without and the second (therapy) with addition oftadalafil 2.5mg/day for 8 weeks, then remeasure all theparameters after. Results blotted in tables and statisticalanalysis done using SPSS program and t-test.Results: There was significant reduction in weight, BMI,FPG, cholesterol, TG and LDL, while no significant change in A1c , and although there was elevation in HDL but was insignificant in control group. In therapy group both weight, BMI, FPG, A1c, cholesterol, TG, and LDL show significant reduction, with mild insignificant elevation in HD. When compare the results of both groups significant results appear in percentage of change of FPG and A1c in therapy group.Conclusion: Low calories diet and exercise are effective inreducing obesity parameters in type 2 diabetes, in addition,improve dysglycemia and dyslipidemia , adding tadalafil2.5mg/day can add beneficial effect specifically for FPG andA1c significantly.
This research deals with the effects of welding variables using MIG/MAG spot by using Argon (Ar) gas and CO2 to show their effect on the mechanical characteristics and microstructure of low alloy steel type DIN15Mo3 and determine the optimum condition for the process of welding ; current & time. The results show the possibility of using CO2 and also Ar in low alloy steel welding with a little decrease in the shear force of not more than 13% for 4mm thickness and time 2sec. The shear force increased when using Ar instead of CO2 to be , The shear force reach 36KN when using Ar at 2mm thickness time of 8 sec and current of 220 Amp. , when used CO2 instead of Ar d
... Show MoreCorrosion Resistance Enhancement for low carbon steel is very important to extend its life service, the coating process is one of the methods which can using to achieve this, and it's the most important in surface treatments to improve the properties of metals and alloys surfaces such as corrosion resistance. In this work, low carbon steel was nitrided and coated with nano zinc using gas phase coating technical, to enhance the resistance of corrosion. The process included adding two layers. The first, a nitride layer, was added by precipitating nitrogen (N) gas, and the second, a zinc (Zn) layer, was added by precipitating Zn. The process of precipitating was carried out at different periods (5, 10, and 15 minutes). Scan electron mi
... Show MoreWith the continuous downscaling of semiconductor processes, the growing power density and thermal issues in multicore processors become more and more challenging, thus reliable dynamic thermal management (DTM) is required to prevent severe challenges in system performance. The accuracy of the thermal profile, delivered to the DTM manager, plays a critical role in the efficiency and reliability of DTM, different sources of noise and variations in deep submicron (DSM) technologies severely affecting the thermal data that can lead to significant degradation of DTM performance. In this article, we propose a novel fault-tolerance scheme exploiting approximate computing to mitigate the DSM effects on DTM efficiency. Approximate computing in hardw
... Show MoreObjectives: The study aims at:
1- Measuring the level of lead in workers’ saliva and blood in the factory.
2- Studying the correlation between the saliva lead level and the infection that caused by microorganisms, isolation and
identification.
3-Studying the influence of high blood lead level on the total white blood cells.
Methodology: This study has been conducted for the period from March 15th, 2010 to May, 20th
, 2010. A total of (60)
saliva and blood samples were collected from workers in batteries industry factory in Baghdad and another (20) samples
were collected as a control group. Lead level had been measured in blood and saliva samples, then microorganisms were
isolated the from the saliva samples.
World statistics proved that the most of work dangerous accidents, which causes death, are occurred in the construction works. These accidents related to many causes such as loss of workers experience and ignoring rules of safety requirements, especially young workers. Due to the risk of accidents that may occur in the site of work, the idea of this study crystallized to show the relationship between the age of worker and number of injuries and accidents, to identify the causes of these injuries, and to put the appropriate solutions to avoid or reduce the risk of work injuries. Also, the research shows the main principles of safety requirements to forming a clear picture about the subject of the study. A questioner form was prepared to c
... Show MoreThis study was carried out to determine the effects of NaCl (0.00, 50, 100, 150, 180 or 200) mM and two different types of mutagens chemical mutagen ethyl methyl sulphonate (EMS) at 0.5% and physical mutagen UV-B irradiation (40 min time exposure), on mitotic division in two Iraqi rice genotypes Amber 33 (A33) and Amber Baghdad (AB). Different concentrations of NaCl were used. Mitotic index (MI %) was decreased significantly by increasing NaCl concentration, however the highest mitotic index was recorded in mutated genotypes with EMS and UV-B. Different abnormal chromosomes were noticed in mutated plants. Results showed high percentage of abnormal chromosomes in EMS mutated genotypes. In addition no significant differences between genotypes
... Show MoreBackground: Occupational exposure to hazardous drugs occurs in all aspects of anticancer drug handling. Proper recommendations and guidelines should be applied to control and reduce exposure. Objective: To assess pharmacists' knowledge and practice regarding the safe handling of anticancer drugs. Methods: A cross-sectional study was conducted at seven major hospitals in Baghdad City, Iraq, from December 2023 to February 2024. A pre-designed questionnaire was given to pharmacists who handled anticancer drugs in chemotherapy units. The questionnaire comprises sociodemographic data, knowledge of the safe handling of cytotoxic drugs and thoughts about exposure and risk, practices for safely handling cytotoxic drugs, and challenges for s
... Show MoreBackground: As a multifactorial disorder, temporomandibular joint (TMD) is difficult to diagnose, and multiple factors affect the joint and cause the temporomandibular disorder. Standardization of clinical diagnosis of TMD should be used to reach a definite clinical diagnosis; the condylar bone may degenerate in accordance with these disorders. Aims: Evaluate the correlation between the clinical diagnosis and degenerative condylar change (flattening, sclerosis, erosion, and osteophyte). Materials and Methods: A prospective study with a study group of 97 TMD patients (total of 194 joints) aged 20 to 50. Patients were sent to cone beam computed tomography (CBCT) to assess the degenerative condylar change. Results: No association was found bet
... Show MoreThe corrosion behavior of low carbon steel in washing water of crude oil solution has been studied potentiostatically at five temperatures in the range ( 303 –343 )K, at pH ( 4 ) and at pH (4,6,7,9,11 ) at (343K)..The corrosion potential shifted to more negative values with increasing temperature and the corrosion current density increased with increasing temperature, the corrosion current density (icorr) decreased with increasing pH in the rang ( 4 – 7 ) and it increased with increasing pH in the rang ( 9 – 11 ) at ( 343 K ), while the corrosion potential generally variation with increasing pH in the rang (4-11)at(343K. From the general results for this study can be seen that thermodynamic and kinetic function were
... Show More