Preferred Language
Articles
/
jkmc-393
Magnetic resonance imaging findings of knee injury
...Show More Authors

Background: Since its introduction to musculoskeletal imaging in the early 1980, magnetic resonance imaging (MRI) has revolutionized diagnostic imaging of the knee. It is therefore become the examination of choice in the evaluation of internal joint structures of the knee like menisci, cruciate ligaments, and articular cartilage.Objectives: to describe the MRI finding in various knee injuries.Patients and methods: A cross sectional study was done on 130 patients with history of knee injury in MRI unit at institute of radiology and al-Shaheed Ghazi Al-Hariri Hospital in medical city complex - Baghdad, from October 2011 to February 2013 includes 103 men, 27 women; the mean age was 33.86 years. MR imaging studies of the knee performed using a 1.5 T MR system. The sequences included coronal and sagittal PD, sagittal T2 FSE, fat suppressed T2 FSE, STIR axial and coronal. Knee MR studies were obtained to evaluate ligament, menisci, articular surface and bone pathologies of knee injuries.Results: MR images were normal in 15 patients; it was positive for meniscal tears in 59 patients and maximum involvement was in the medial meniscus and the posteriorhorn. These tears were classified into grade 1 (28.8%), grade 2 (11.5%), grade 3 (53.9%) and grade 4 (5.8%). Ligament tears were seen in 70 patients. Secondary signs associated with ligament tears were also assessed.Conclusions: MRI is an accurate, non-invasive technique for examination of the soft tissues and osseous structures of the knee. It has great capability in diagnosing meniscal tears and classifying them into grades and types, which would avoid unnecessary arthroscopic examination. It is a very good modality to diagnose complete tears of the anterior cruciate ligament (ACL).maging, meniscus

View Publication Preview PDF
Quick Preview PDF
Publication Date
Mon Jan 01 2024
Journal Name
Optical Materials
Design and analysis of a high sensitivity open microchannel PCF-based surface plasmon resonance refractometric sensor
...Show More Authors

View Publication
Scopus (29)
Crossref (30)
Scopus Clarivate Crossref
Publication Date
Sun Sep 07 2014
Journal Name
Baghdad Science Journal
Comparison the effectiveness of using a magnetic field to control theColi phages isolated from rivulet water with water-treatment using magnetic field added iron filings
...Show More Authors

The present study aimed to use the magnetic field and nanotechnology in the field of water purification, which slots offering high efficiency to the possibility of removing biological contaminants such as viruses and bacteria rather than the use of chemical and physical transactions such as chlorine and bromine, and ultraviolet light and boiling and sedimentation and distillation, ozone and others that have a direct negative impact on human safety and the environment. Where they were investigating the presence in water samples under study Coli phages using Single agar layer method and then treated samples positive for phages to three types of magnetic field fixed as follows (North Pole - South Pole - Bipolar) and compare the re

... Show More
View Publication Preview PDF
Crossref
Publication Date
Wed Aug 31 2022
Journal Name
Al-kindy College Medical Journal
Assessment of Awareness And Knowledge among Medical Students Regarding Radiation Exposure from Common Diagnostic Imaging Procedures: Radiation exposure awareness among medical students
...Show More Authors

Objective: to assess the awareness and knowledge of our medical students regarding dose levels of imaging procedures and radiation safety issues, and to conclude how the curriculum of clinical radiology in the college medical program impacts such knowledge.

Subjects and methods:  this is a cross-sectional study conducted among 150 medical students in Alkindy College of Medicine between January 2021 to July 2021, regardless of their age or gender. The study included six grades according to the year 2020-2021. A questionnaire consisting of 12 multiple-choice questions was conducted via an online survey using Google Forms. The questions were divided into two parts

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Wed Mar 01 2023
Journal Name
Iraqi Journal Of Physics
Evaluation of Resonance Strengths and Reaction Rates of 22Ne (p, gamma) 23Na Nuclear Reaction at Thermonuclear Energies
...Show More Authors

At thermal energies near stellar conditions, nuclear reactions are sensitive to resonance strengths of the nuclear reaction cross-section. In this paper, the resonance strengths of  nuclear reaction were evaluated numerically by means of nuclear reaction rate calculations using a written Matlab code, at the energies of interest in stellar nuclear reactions. The results were compared with standard reaction before and after application of a statistical analyses, to select the best parameters that made theoretical results as close as possible to the standard values. Fitting was made for different temperature ranges up to 10 GK, 0.6 GK and 0.25 GK. The evaluated results showed that as the temperature range becomes narrower, more error is ad

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Sun Jun 01 2014
Journal Name
Baghdad Science Journal
The Effect of Magnetic Water for Chemical Fertilizer in Tomato Plant
...Show More Authors

The research aims to find ways to minimize the use of quantities of chemical fertilizers in agriculture in order to get to an environment that is free of contaminants. Magnetized water technology used in the experience of planting seeds of tomatoes Thomson type to obtain a higher efficiency to absorb fertilizer NRK in the protected environment of the period from February to June. Magnetized water system used locally made levels Gaues (4800,2500,1500) concentrations of 50 to 100% for each level and the rate of (4) replicates, and results indicated that the severity of the magnet (4800 Gaues) and a concentration of 50% gave the highest percentage of tomato fruit size and intensity ( 1500 Gaues) and a concentration of 100% did not give any inc

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Sat Oct 25 2025
Journal Name
Journal Of Physical Education
The Effect Of Absolute Strength Training On Knee Injuries Rehabilitation And Special Strength In Muay Thai Fighters
...Show More Authors

View Publication
Publication Date
Fri Aug 26 2022
Journal Name
Surgical Neurology International
Excellent recovery after nonmissile penetrating traumatic brain injury in a child: A case report
...Show More Authors
Background:

Nonmissile penetrating traumatic brain injuries (pTBIs) are low-velocity injuries which can be caused by a variety of inflicting tools and represent a rare entity in children. Poor outcome has been attributed with an initial admission Glasgow Coma Scale (GCS) of <5, asymmetrical pupil size, and specific initial computed tomography scan findings including brainstem injury.

Case Description:

We report a case of an 11-year-old boy who presented to our ER with a GCS of 6 after being assaulted on his head by a 30 cm length metallic tent hook penetrating his forehead reaching down to the central skull bas

... Show More
View Publication Preview PDF
Scopus (2)
Crossref (4)
Scopus Crossref
Publication Date
Tue Sep 01 2020
Journal Name
Iraqi Journal Of Physics
The magnetic switch manufacturing by using ferrofluid and ferrofluid doped copper nanoparticles
...Show More Authors

In this work, a magnetic switch was prepared using two typesof ferrofluid materials, the pure ferrofluid and ferrofluid doped with copper nanoparticles (10 nm). The critical magnetic field (Hc) and the state of magnetic saturation (Hs) were studied using three types of laser sources. The main parameters of the magnetic switch measured using pure ferrofluid and He-Ne Laser source were Hc(0.5 mv, 0.4 G), Hs (8.5 mv, 3 G). For the ferrofluid doped with copper nanoparticles were Hc (1 mv, 4 G), Hs (15 mv, 9.6 G), Using green semiconductor laser for the Pure ferrofluid were Hc (0.5 mv, 0.3 G) Hs (15 mv, 2.9 G). While the ferrofluid doped with copper nanoparticles were Hc (0.5 mv, 1 G), Hs (12 mv, 2.8 G) and by using the violet semiconductor l

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sat Oct 01 2016
Journal Name
Journal Of Engineering
Non-Destructive Testing of Carbon Fiber Reinforced Magnetic Reactive Powder Concrete Containing Nano Silica
...Show More Authors

This study involves the design of 24 mixtures of fiber reinforced magnetic reactive powder concrete containing nano Silica. Tap water has been used in mixing 12 of these mixtures, while the other 12 have been mixed using magnetic water. Nano Silica (NS) with ratios (1, 1.5, 2, 2.5 and 3) % were used. The results showed that the mixture containing 2.5%NS gives the highest compressive strength at age 7 days. Many different other tests were carried out, the results showed that the fiber reinforced magnetic reactive powder concrete containing 2.5% NS (FRMRPCCNS)  has the higher bulk density, dynamic modulus of elasticity, ultrasonic pulse velocity  electrical resistivity and lesser absorption than fiber reinforced

... Show More
View Publication Preview PDF
Publication Date
Sun Jul 28 2019
Journal Name
Open Access Macedonian Journal Of Medical Sciences
Value of Combination of Standard Axial and Thin-Section Coronal Diffusion-weighted Imaging in Diagnosis of Acute Brainstem Infarction
...Show More Authors

AIM: To determine the value of the combination of thin-section 3 mm ‎coronal and standard ‎axial DWI and their impact in facilitating the diagnosis of ‎‎acute brainstem infarction. METHODS: A cross-sectional study conducted from the 1st of April 2017 to the end of February 2018 on 100 consecutive patients (66% were male, and 34% were female) with isolated acute ischemic infarction in the ‎brainstem. The abnormal MRI findings concerning the ischemic lesions were interpreted on standard axial 5 mm and thin-section coronal 3mm DWI. RESULTS: The mean age of the studied group was 69.2 ± 4.3 for male and 72.3 ± 2.5 years. The standard axial DWI can diagnose 20%, 6.7% and 6.7% of the infarctions in midbrain, pons an

... Show More
View Publication
Scopus (3)
Crossref (3)
Scopus Crossref