Preferred Language
Articles
/
jkmc-372
Precision of pachymetric measurements with Scheimpflug –Placido disc cornealTopography and comparison of these measurements with ultrasonic pachymetry
...Show More Authors

Back ground: Several devices with different physical bases have been developed for the clinical measurement of corneal thickness, they classified into 4 categories: Scheimpflug photography based, Slit –Scanning topography, optical coherence tomography (OCT) based and ultrasound (US) based.Objective:To evaluatethe precision of the new Scheimpflug –Placido disc corneal topography in measurement of corneal thickness and to compare the measured values with that obtained by US pachymetry.Methods: Setting of this study is Lasik center in Eye Specialty Private Hospital. Baghdad. Iraq.Eyes of healthy subjects were examined with the Sirius topography.3 consecutive measurements of central (CCT)and thinnest (TCT) corneal thicknesses were obtainedand the measurements repeated within 1 week. The within –subject standard deviation (Sw),test-retest repeatability ,coefficient of variation (CoV),and interclass correlation coefficient (ICC) were calculated to evaluate intra session repeatability and intersession reproducibility. For US pachymetry (Tomey-SP 100) only CCT was measured. Comparison ofthe measurements that obtained by the 2 devices done by paired t-test.Results: The topography provides high intrasession repeatability with test-retest and CoV close to 6μm and0.4%, respectively for both CCT and TCT. The inter session reproducibility also high with test-retest and CoV close to 8μm and 0.5%, respectively.ICC was higher than 0.97 for repeatability and reproducibility . Anarrow 95% limit of agreement was found between the pachymetry obtained by topography and US pachymetry measurements.Conclusions :The topography has been used showed high intrasession repeatability and intersession reproducibility of CCT and TCT measurements in healthy eyes .Absence of statistically significant differences suggest that the topography -TCT and the US pachymetry - CCT can be used interchangeably in subject with normal cornea.Financial Disclosure: No financial or proprietary interest in any material or method mentioned.

View Publication Preview PDF
Quick Preview PDF
Publication Date
Thu Oct 17 2024
Journal Name
South Eastern European Journal Of Public Health
Evaluation of Lifestyle for Women with Breast Cancer
...Show More Authors

Introduction: Breast cancer is a significant global health concern, affecting millions of women worldwide. While advancements in diagnosis and treatment have improved survival rates, the impact of this disease extends beyond physical health. It also significantly influences a woman's lifestyle and overall well-being. Objectives: The current study intends to analyze the lifestyle of breast cancer patients who are receiving therapy or are being followed up at the Oncology Teaching Hospital in Medical City, Baghdad, Iraq. Method: The present study uses a descriptive design with an application of an evaluation approach. A convenience sample of 100 women with breast cancer was selected from the Teaching Oncology Hospital at the Medical C

... Show More
View Publication
Crossref
Publication Date
Sat Oct 01 2011
Journal Name
Iraqi Journal Of Physics
Preparation of nano-microfibers with a different polymers
...Show More Authors

Abstract: In this research, nanofibers have been prepared by using an electrospinning method. Three types of polymer (PVA, VC, PMMA) have been used with different concentration. The applied voltage and the gap length were changed. It was observed that VC is the best polymer than the other types of polymers.

Preview PDF
Publication Date
Sun Feb 01 2015
Journal Name
Journal Of Engineering
Vibration Analysis of a Composite Plate with Delamination
...Show More Authors

The use of composite materials has vastly increased in recent years. Great interest is therefore developed in the damage detection of composites using non- destructive test methods. Several approaches have been applied to obtain information about the existence and location of the faults. This paper used the vibration response of a composite plate to detect and localize delamination defect based on the modal analysis. Experiments are conducted to validate the developed model. A two-dimensional finite element model for multi-layered composites with internal delamination is established. FEM program are built for plates under different boundary conditions. Natural frequencies and modal displacements of the intact and damaged

... Show More
View Publication Preview PDF
Publication Date
Thu Dec 30 2004
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Simulation of naturally Fractured Reservoirs with SimBest ll
...Show More Authors

View Publication Preview PDF
Publication Date
Sat Aug 01 2020
Journal Name
Key Engineering Materials
Performance of Reinforced Concrete Beams with Multiple Openings
...Show More Authors

The present investigation focuses on the response of simply supported reinforced concrete rectangular-section beams with multiple openings of different sizes, numbers, and geometrical configurations. The advantages of the reinforcement concrete beams with multiple opening are mainly, practical benefit including decreasing the floor heights due to passage of the utilities through the beam rather than the passage beneath it, and constructional benefit that includes the reduction of the self-weight of structure resulting due to the reduction of the dead load that achieves economic design. To optimize beam self-weight with its ultimate resistance capacity, ten reinforced concrete beams having a length, width, and depth of 2700, 100, and

... Show More
View Publication Preview PDF
Scopus (5)
Crossref (5)
Scopus Crossref
Publication Date
Mon Mar 08 2021
Journal Name
Baghdad Science Journal
Variational Formulation with Deviating Arguments of Movable boundaries
...Show More Authors

In this paper, we study, in details the derivation of the variational formulation corresponding to functional with deviating arguments corresponding to movable boundaries. Natural or transversility conditions are also derived, as well as, the Eulers equation. Example has been taken to explain how to apply natural boundary conditions to find extremal of this functional.

View Publication Preview PDF
Publication Date
Sun Oct 01 2023
Journal Name
History Of Medicine
Correlation of Afamin with oxidative stress in GDM
...Show More Authors

It is becoming a public health issue to predict which expectant women will develop gestational diabetes mellitus (GDM). The goal of this case control research is to investigate the role of maternal oxidative stress levels in the first, second, and third trimesters, as well as other factors, in the development of gestational diabetes mellitus (GDM). Methods Between October and December 2021, 142 women participated in this research. The 101 GDM patients were split into three groups based on their gestation (T1, T2, and T3), and 41 healthy pregnant women were chosen as the comparison group. TAS and TOS levels of oxidative stress and XO were calculated using a Spectrophotometer for colorimetric techniques; fasting and random sugar levels, as

... Show More
Publication Date
Sat Oct 01 2011
Journal Name
Iraqi Journal Of Physics
Preparation of nano-microfibers with a different polymers
...Show More Authors

In this research, nanofibers have been prepared by using an electrospinning method. Three types of polymer (PVA, VC, PMMA) have been used with different concentration. The applied voltage and the gap length were changed. It was observed that VC is the best polymer than the other types of polymers.

View Publication Preview PDF
Publication Date
Thu Jan 01 2015
Journal Name
Ibn Al-haitham Jour. For Pure & Appl. Sci
Swelling Behavior of Cross-link PVA with Glutaraldehyde
...Show More Authors

The polymeric hydrogels composed of poly vinyl alcohol (m.wt 72000) and glutaraldehyde(5%,8% and 10%) , have been thermally prepared for the purpose of studying their swelling and drug release behavior . The swelling ratio was measured for all the hydrogel samples at 37°C, in three different media pH (1.2, 4.7 and 6.8) as a function of time. The results show that the maximum swelling ratios were arranged as follows :pH =6.8 > pH =4.7 > pH =1.2 hydrogels cross linked PVA showed a typical pH responsive behavior such as high pH has maximum swelling while low pH shows minimum swelling.

Publication Date
Sun Jun 30 2002
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Characteristic of Absorption with Reaction in Packed Column
...Show More Authors

View Publication Preview PDF