Background: Background : Patients with non-rheumatic atrial fibrillation have high risk of thromboembolism especially ischemic stroke usually arising from left atrial appendage .Transoesophageal echocardiography provides useful information for risk stratification in these patients as it detects thrombus in the left atrial or left atrial appendage. Objective : This study was conducted at Al-Kadhimiya Teaching Hospital to assess the prevalence of left atrial chamber thrombi in patients with chronic non-rheumatic atrial fibrillation using transoesophageal echocardiography and its clinical significance as well as to verify the superiority of transoesophageal over transthoracic echocardiography in the detection of these abnormalities. Type of the study: Cross sectional study.Patients and Methods : Forty (40) consecutive patients (11 female and 29 male), at a mean age of 46 ± 9 years (range 28–60) with chronic non-rheumatic Atrial fibrillation were enrolled to this prospective study between March 2006 and December 2006. Tansthoracic and transesophageal two dimensional , M- mode , Doppler, and color- flow echocardiography were obtained with a kretz diagnostic ultrasound system. Results : The prevalence of Left atrium thrombus was 12.5%, 5 patients from the total number which was 40 patients. All of them seen bytransoesophagealechocardiography and non are detected byTansthoracic echocardiography . All the left atrial thrombi were confined to the left atrial appendage (100%). Left atrial spontaneous echo contrast was detected in 10 patients 25% by transoesophageal echocardiography, but was not observed in patient bytransthoracic echocardiography. All the 5 thrombi were found in left atria were significantly associated with spontaneous echo contrast 100% (P-value <0.001), reduced left ventricle ejection fraction (p-value <0.05) , large left atrium diameter ( p-value <0.05) and low LAAV <20 cm/s (p-value <0.001) compared to those without thrombus . Conclusions : The study showed that the prevalence of left atrial thrombus and appendage is not uncommon in patients with non-rheumatic atrial fibrillation and is exclusively seen in patients with left atrial SEC. Low Left ventricle ejection fraction , large Left atrium diameter , and low Left atrial appendages velocity are significantly associated with subsequent thrombus formation , and is more sensitive in the detection of these abnormalities compared with transthoracic echocardiography
This paper presents the design and analysis of composite right left hand (CRLH) electromagnetic bandgap (EBG) structure. The proposed unit cell is consistent of a dielectric substrate with dimensions of 5×5×1 mm 3 made of FR4-Epoxy with εr = 4.4 underneath of a conductive patch with dimensions of 4.4×4.4mm 2 . The unit cell is structured to perform a negative permittivity (ε) and negative permeability (µ) in different bands. The proposed unit cell is developed to 5G systems in the sub-6GHz bands. In this work, a complete analysis of the unit cell in terms of Sparameters, constitutive parameters and refraction index are evaluated using HFSS simulation package based on Finite Element Method (FEM).
BACKGROUND: HLA-B27 can effect clinical presentation and course of ankylosing spondylitis. Different detection techniques of HLA-B27 are available with variable sensitivities and specificities. OBJECTIVE: To compare serologic and molecular diagnostic techniques of detecting HLA-B27 status and to correlate it with some clinical variables among ankylosing spondylitis patients. PATIENTS AND METHODS: A cross-sectional study was conducted on 83 Iraqi patients with ankylosing spondylitis. Clinical and laboratory evaluations were reported. HLA-B27 status was determined in all patients by real-time PCR using HLA-B27 RealFast™ kit; ELISA method was used as well to detect soluble serum HLA-B27 antigens using Human Leukocyte Antigen® kit. RESULTS:
... Show MoreA liquid membrane process of Alkaloids extraction from Datura Innoxia solution was studied applying pertraction process in rotating discs contactor (RDC). Decane as a liquid membrane and dilute sulphuric acid as stripping solution were used. The effect of the fundamental parameters influencing the transport process, eg type of solvent used, effect of disks speed, amount of liquid membrane and effect of pH for feed and strip solution. The transport of alkaloids was analysed on the basis of kinetic laws of two consecutive irreversible first order reactions. Thus, the kinetic parameters (k1, k1,, tmax, and) for the transport of alkaloids were determined. The effect of organic membrane type on percentage of Alkaloids transport was found to be i
... Show MoreA liquid membrane process of Alkaloids extraction from Datura Innoxia solution was studied applying pertraction process in rotating discs contactor (RDC). Decane as a liquid membrane and dilute sulphuric acid as stripping solution were used. The effect of the fundamental parameters influencing the transport process, e.g. type of solvent used, effect of disks speed, amount of liquid membrane and effect of pH for feed and strip solution. The transport of alkaloids was analysed on the basis of kinetic laws of two consecutive irreversible first order reactions. Thus, the kinetic parameters (k1, k1, , tmax, and ) for the transport of alkaloids were determined. The effect of organic membrane type on percentage of Alkaloids transport was found
... Show MoreIschemic heart disease is a major causes of heart failure. Heart failure patients have predominantly left ventricular dysfunction (systolic or diastolic dysfunction, or both). Acute heart failure is most commonly caused by reduced myocardial contractility, and increased LV stiffness. We performed echocardiography and gated SPECT with Tc99m MIBI within 263 patients and 166 normal individuals. Left ventricular end systolic volume (LVESV), left ventricular end diastolic volume (LVEDV), and left ventricular ejection fraction (LVEF) were measured. For all degrees of ischemia, there was a significant difference between ejection fraction values measured by SPECT and echo
The dangerous and potentially blinding condition known as Acanthamoeba keratitis is caused by free-living amoebae of the genus Acanthamoeba. The prevalence of AIDS patients and contact lens wearers has increased in recent years, making cannaeba infections more significant. It's interesting to note that, depending on the parasite, host, and environmental conditions, the pathways linked to Acanthamoeba pathogenesis are frequently extremely complex. Notwithstanding our progress in antibiotic therapy and supportive care, the prevalence of Acanthamoeba keratitis has not decreased
The aim of the present study was to distinguish between healthy children and those with epilepsy by electroencephalography (EEG). Two biomarkers including Hurst exponents (H) and Tsallis entropy (TE) were used to investigate the background activity of EEG of 10 healthy children and 10 with epilepsy. EEG artifacts were removed using Savitzky-Golay (SG) filter. As it hypothesize, there was a significant changes in irregularity and complexity in epileptic EEG in comparison with healthy control subjects using t-test (p< 0.05). The increasing in complexity changes were observed in H and TE results of epileptic subjects make them suggested EEG biomarker associated with epilepsy and a reliable tool for detection and identification of this di
... Show More